Belden 8771 060 is a 3 conductor 22 AWG multi-conductor cable for low voltage signal and control wiring. It features stranded (7x30) TC - tinned copper conductors with PE - polyethylene insulation and an overall Beldfoil® shield with 100% coverage plus a 22 AWG (7x30) TC drainwire. The PVC - polyvinyl chloride outer jacket is rated CM for indoor installations. Electrical characteristics include 17.8 Ohm/1000ft Nom. Conductor DCR and a UL voltage rating of 300 V (CM), 300 V (UL AWM 2093).
Belden 8771 060 Key Features
- This cable uses a 3 conductor 22 AWG construction with stranded (7x30) TC - tinned copper conductors.
- It includes an overall Beldfoil® shield with 100% coverage and a 22 AWG (7x30) TC drainwire.
- PE - polyethylene insulation is color coded: Black, Red, Clear.
- The PVC - polyvinyl chloride outer jacket is CM rated for indoor use.
- UL voltage rating: 300 V (CM), 300 V (UL AWM 2093).
Belden 8771 060 Technical Specs
Construction & Physical Specs
| Insulation thickness (nom.) | 0.017 in (0.43 mm) |
|---|---|
| Insulation diameter (nom.) | 0.062 in (1.6 mm) |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield construction | Overall Shield & drain |
| Jacket thickness (nom.) | 0.033 in (0.84 mm) |
| Overall cable diameter (nominal) | 0.199 in (5.05 mm) |
| Bulk cable weight | 22 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. capacitance Cond-to-Cond | 23 pF/ft (75 pF/m) |
|---|---|
| Nom. capacitance Cond-to-other (conds + Shield) | 41 pF/ft (130 pF/m) |
| Max. current | 6 Amps per Conductor at 30ºC |
| Nom outer Shield DCR | 12.86 Ohm/1000ft (42.19 Ohm/km) |
Environmental & Mechanical Ratings
| UL temperature | 60°C |
|---|---|
| Operating | -20°C to +60°C |
| Bend radius (stationary min.) | 0.56 in (14 mm) |
| Bend radius (installation min.) | 2.0 in (51 mm) |
| Max. pull tension | 36.4 lbs (16.5 kg) |
| Environmental suitability | Indoor |
Compliance & Certifications
| NEC / UL compliance | Article 800, CM |
|---|---|
| AWM compliance | AWM 2093 |
| CEC / C(UL) compliance | CM |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
Belden 8771 060 Applications
- It supports low voltage analog signals such as 4-20ma and 0-10v in signal and control wiring runs.
- For low voltage control circuits, it is suitable for 24v control where consistent signal wiring is needed.
- In indoor installations, it is commonly used for line level audio and voice communications wiring.
- For panel wiring, it fits applications where a multi-conductor, shielded construction is specified.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Insulation thickness (nom.) | 0.017 in (0.43 mm) |
| Insulation diameter (nom.) | 0.062 in (1.6 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield construction | Overall Shield & drain |
| Jacket thickness (nom.) | 0.033 in (0.84 mm) |
| Overall cable diameter (nominal) | 0.199 in (5.05 mm) |
| Bulk cable weight | 22 lbs/1000ft |
| Nom. capacitance cond-to-cond | 23 pF/ft (75 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 41 pF/ft (130 pF/m) |
| Max. current | 6 Amps per Conductor at 30ºC |
| Nom. outer shield DCR | 12.86 Ohm/1000ft (42.19 Ohm/km) |
| UL temperature | 60°C |
| Operating | -20°C to +60°C |
| Bend radius (stationary min.) | 0.56 in (14 mm) |
| Bend radius (installation min.) | 2.0 in (51 mm) |
| Max Pull Tension | 36.4 lbs (16.5 kg) |
| Environmental suitability | Indoor |
| NEC / UL compliance | Article 800, CM |
| AWM compliance | AWM 2093 |
| CEC / C(UL) compliance | CM |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.