Belden 8772 060 is a 3 conductor 20 AWG multi-conductor cable designed for reliable signal and control wiring in indoor environments. It uses 20 AWG (7x28) tinned copper conductors with PE insulation and an overall tape shield with 100% coverage, plus a 20 AWG (7x28) TC drainwire for grounding. The cable is finished with a PVC outer jacket and carries a UL voltage rating of 300 V (CM), 300 V (UL AWM 2093). It is specified for low voltage analog signals (4-20ma, 0-10v, ...), low voltage control (24v, …), line level audio, voice communications, and panel wiring.
Belden 8772 060 Key Features
- This cable features a 3 conductor 20 AWG construction with 20 AWG (7x28) tinned copper conductors.
- It uses PE insulation with color code: Black, Red, Clear.
- It includes an overall tape shield with Bi-Laminate (Alum+Poly) material and 100% shield coverage.
- A 20 AWG (7x28) TC drainwire is included with shield construction: Overall Shield & drain.
- It has a PVC - Polyvinyl Chloride outer jacket.
- UL voltage rating: 300 V (CM), 300 V (UL AWM 2093).
- Environmental suitability: Indoor.
Belden 8772 060 Technical Specs
Electrical & Physical Specs
| Insulation thickness (nom.) | 0.017 in (0.43 mm) |
|---|---|
| Insulation diameter (nom.) | 0.070 in (1.8 mm) |
| Jacket thickness (nom.) | 0.033 in (0.84 mm) |
| Jacket diameter (nom.) | 0.218 in (5.54 mm) |
| Overall cable diameter (nom.) | 0.218 in (5.54 mm) |
| Bulk cable weight | 28 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. conductor DCR | 11.1 Ohm/1000ft |
|---|---|
| Nom. capacitance cond-to-cond | 27 pF/ft (89 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 51 pF/ft (170 pF/m) |
| Max. current | 8 Amps per Conductor at 30ºC |
| Nom outer shield DCR | 8.08 Ohm/1000ft (26.5 Ohm/km) |
Environmental & Mechanical Ratings
| UL temperature | 60°C |
|---|---|
| Operating temperature | -20°C to +60°C |
| Bend radius (stationary min.) | 2.2 in (56 mm) |
| Bend radius (installation min.) | 2.2 in (56 mm) |
| Max. pull tension | 50.4 lbs (22.9 kg) |
Compliance & Certifications
| NEC / UL compliance | Article 800, CM |
|---|---|
| CEC / C(UL) compliance | CM |
| AWM compliance | AWM 2093 |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
Applications
- Low voltage analog signals (4-20ma, 0-10v, ...) are supported where consistent signal transmission is needed.
- Low voltage control (24v, …) wiring is supported in control and automation circuits.
- Line level audio connections are suitable where shielding is used to help manage noise in sensitive circuits.
- Voice communications wiring can be used in indoor installations.
- Panel wiring is intended where organized multi-conductor runs are required.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Insulation thickness (nom.) | 0.017 in (0.43 mm) |
| Insulation diameter (nom.) | 0.070 in (1.8 mm) |
| Jacket thickness (nom.) | 0.033 in (0.84 mm) |
| Jacket diameter (nom.) | 0.218 in (5.54 mm) |
| Overall cable diameter (nom.) | 0.218 in (5.54 mm) |
| Bulk cable weight | 28 lbs/1000ft |
| Nom. conductor DCR | 11.1 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 27 pF/ft (89 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 51 pF/ft (170 pF/m) |
| Max. current | 8 Amps per Conductor at 30ºC |
| Nom. outer shield DCR | 8.08 Ohm/1000ft (26.5 Ohm/km) |
| UL temperature | 60°C |
| Operating temperature | -20°C to +60°C |
| Bend radius (stationary min.) | 2.2 in (56 mm) |
| Bend radius (installation min.) | 2.2 in (56 mm) |
| Max Pull Tension | 50.4 lbs (22.9 kg) |
| NEC / UL compliance | Article 800, CM |
| CEC / C(UL) compliance | CM |
| AWM compliance | AWM 2093 |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.