Belden 9116SB 010, Coax Shipboard CATV Cable 18 AWG FRNHPO Black

SKU:Belden 9116SB 010
● Auf Lager
Beschreibung
Belden 9116SB 010 is a 75 Ohm SDI coax (RG-6) for digital video and HD-SDI 1080p performance in marine shipboard and offshore environments. It features an 18 AWG solid BCCS - Bare Copper Covered Steel Conductor with gas-injected PE - Polyethylene (Foam) insulation and an LSZH jacket. Shielding uses Duobond® II tri-laminate tape plus an aluminum braid, and the cable is shipboard ABS type approved with CMG-LS compliance.
Belden 9116SB 010 Key Features
- 75 Ohm SDI coax (RG-6) designed for digital video and HD-SDI 1080p performance.
- 18 AWG solid BCCS - Bare Copper Covered Steel Conductor for consistent construction.
- Gas-injected PE - Polyethylene (Foam) insulation with 83% nominal velocity of propagation.
- Duobond® II tri-laminate tape shield plus an aluminum braid for braid over foil shielding.
- LSZH jacket to support limited-smoke requirements.
- Shipboard ABS type approved construction with NEC / UL compliance: Article 800, CMG-LS and CEC / C(UL) compliance: CMG-LS.
Belden 9116SB 010 Technical Specs
Construction & Physical Specs
| Coax construction | Coaxial |
|---|---|
| Series type | 6 |
| Number of elements | 1 |
| Nom. diameter | 0.04 in |
| Nom. insulation diameter | 0.18 in (4.6 mm) |
| Overall cable diameter (nominal) | 0.274 in (6.96 mm) |
| Bulk cable weight | 28 lbs/1000ft |
| Flooded | No not flooded over braid |
| Color code | White |
| Insulation notes | Gas Injected |
| Shield type | Both, braid over foil |
| Shield layer 1 | Tape, Tri-Laminate (Alum+Poly+Alum), Duobond® II, 100% |
| Shield layer 2 | Braid, Aluminum, 57% |
| Outer jacket material | PO - Polyolefin |
Electrical Characteristics
| Nom. capacitance cond-to-shield | 16.2 pF/ft (53.1 pF/m) |
|---|---|
| Nom. conductor DCR | 28 Ohm/1000ft (92 Ohm/km) |
| Nom. outer shield DCR | 9 Ohm/1000ft (30 Ohm/km) |
| UL voltage rating | 300 V RMS |
Performance (Return Loss & Attenuation)
| Return loss 5-1000 MHz | 20 dB |
|---|---|
| Return loss 1000-2250 MHz | 15 dB |
| Return loss 2250-3000 MHz | 10 dB |
| Attenuation (max.) 5 MHz | 0.67 dB/100ft |
| Attenuation (max.) 55 MHz | 1.6 dB/100ft |
| Attenuation (max.) 211 MHz | 2.87 dB/100ft |
| Attenuation (max.) 270 MHz | 3.24 dB/100ft |
| Attenuation (max.) 300 MHz | 3.43 dB/100ft |
| Attenuation (max.) 350 MHz | 3.72 dB/100ft |
| Attenuation (max.) 400 MHz | 4 dB/100ft |
| Attenuation (max.) 450 MHz | 4.26 dB/100ft |
| Attenuation (max.) 5500 MHz | 4.71 dB/100ft |
| Attenuation (max.) 750 MHz | 5.59 dB/100ft |
| Attenuation (max.) 870 MHz | 6 dB/100ft |
| Attenuation (max.) 1000 MHz | 6.54 dB/100ft |
| Attenuation (max.) 1450 MHz | 8.3 dB/100ft |
| Attenuation (max.) 1800 MHz | 9.3 dB/100ft |
| Attenuation (max.) 2250 MHz | 10.6 dB/100ft |
| Attenuation (max.) 3000 MHz | 11.9 dB/100ft |
Environmental & Mechanical Ratings
| Operating | -20°C To +75°C |
|---|---|
| UL temperature | 75°C |
| Stationary min. bend radius | 2.75 in (69.9 mm) |
| Installation min. bend radius | 2.75 in (69.9 mm) |
| Max. pull tension | 126 lbs (57.2 kg) |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance |
Compliance & Certifications
| Marine compliance | ABS Type Approval Certificate 19-HS1852547-PDA |
|---|---|
| Flammability / reaction to fire | UL1685 FT4 Loading, Limited Smoke, FT4, 1202, IEC 60332-1-2, IEC 60332-3-22 |
| CPR compliance | CPR Euroclass: Eca |
| IEEE compliance | Std. 45 clause 23 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 9116SB 010 Applications
- Use it for digital video signal transmission.
- Support HD-SDI 1080p applications with this cable.
- Specify it for ABS approved marine shipboard and offshore use.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| Series type | 6 |
| Number of elements | 1 |
| Nom. diameter | 0.04 in |
| Nom. insulation diameter | 0.18 in (4.6 mm) |
| Overall cable diameter (nominal) | 0.274 in (6.96 mm) |
| Bulk cable weight | 28 lbs/1000ft |
| Flooded | No not flooded over braid |
| Color Code | White |
| Insulation notes | Gas Injected |
| Shield Type | Both, braid over foil |
| Shield layer 1 | Tape, Tri-Laminate (Alum+Poly+Alum), Duobond® II, 100% |
| Shield layer 2 | Braid, Aluminum, 57% |
| Outer jacket material | PO - Polyolefin |
| Nom. capacitance (Cond-to-Shield) | 16.2 pF/ft (53.1 pF/m) |
| Nom. conductor DCR | 28 Ohm/1000ft (92 Ohm/km) |
| Nom. outer shield DCR | 9 Ohm/1000ft (30 Ohm/km) |
| UL Voltage Rating | 300 V RMS |
| Return loss 5-1000 MHz | 20 dB |
| Return loss 1000-2250 MHz | 15 dB |
| Return loss 2250-3000 MHz | 10 dB |
| Attenuation (max.) 5 MHz | 0.67 dB/100ft |
| Attenuation (max.) 55 MHz | 1.6 dB/100ft |
| Attenuation (max.) 211 MHz | 2.87 dB/100ft |
| Attenuation (max.) 270 MHz | 3.24 dB/100ft |
| Attenuation (max.) 300 MHz | 3.43 dB/100ft |
| Attenuation (max.) 350 MHz | 3.72 dB/100ft |
| Attenuation (max.) 400 MHz | 4 dB/100ft |
| Attenuation (max.) 450 MHz | 4.26 dB/100ft |
| Attenuation (max.) 5500 MHz | 4.71 dB/100ft |
| Attenuation (max.) 750 MHz | 5.59 dB/100ft |
| Attenuation (max.) 870 MHz | 6 dB/100ft |
| Attenuation (max.) 1000 MHz | 6.54 dB/100ft |
| Attenuation (max.) 1450 MHz | 8.3 dB/100ft |
| Attenuation (max.) 1800 MHz | 9.3 dB/100ft |
| Attenuation (max.) 2250 MHz | 10.6 dB/100ft |
| Attenuation (Max.) 3000 MHz | 11.9 dB/100ft |
| Operating | -20°C To +75°C |
| UL temperature | 75°C |
| Stationary min. bend radius | 2.75 in (69.9 mm) |
| Installation min. bend radius | 2.75 in (69.9 mm) |
| Max Pull Tension | 126 lbs (57.2 kg) |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance |
| Marine compliance | ABS Type Approval Certificate 19-HS1852547-PDA |
| Flammability / reaction to fire | UL1685 FT4 Loading, Limited Smoke, FT4, 1202, IEC 60332-1-2, IEC 60332-3-22 |
| CPR compliance | CPR Euroclass: Eca |
| IEEE compliance | Std. 45 clause 23 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.