Belden 9259 010, Coax RG 59 U 22 AWG 75 Ohm PE Black

SKU:Belden 9259 010
● Auf Lager
Beschreibung
Belden 9259 010 is a 75 Ohm analog video coax in RG 59 format for standard analog video signal transmission. It features a 22 AWG (7x30) BC - Bare Copper stranded conductor, PE - Polyethylene (Foam) insulation, and a 95% Bare Copper braid shield. The PVC - Polyvinyl Chloride jacket in Black is suited to Indoor (Not Riser or Plenum), Indoor, Aerial - Black only, When supported by messenger Wire environments. It meets CM and AWM 1354 compliance and carries a UL Voltage Rating of 300 V (CM), 30 V (UL AWM 1354).
Belden 9259 010 Key Features
- 75 Ohm analog video coax in RG 59 format for standard analog video signal transmission.
- 22 AWG (7x30) BC - Bare Copper stranded conductor.
- PE - Polyethylene (Foam) insulation with White color code.
- 95% Bare Copper (BC) braid shield (Braid only).
- PVC - Polyvinyl Chloride jacket in Black.
- Compliance: CM and AWM 1354.
- UL Voltage Rating: 300 V (CM), 30 V (UL AWM 1354).
Belden 9259 010 Technical Specs
Construction & Physical Specs
| Coax construction | Coaxial |
|---|---|
| Overall cable diameter (nominal) | 0.240 in (6.10 mm) |
| Conductor nom. diameter | 0.029 in |
| Nom. insulation diameter | 0.146 in (3.71 mm) |
| Dielectric material | FPE-Foamed (Cellular) Polyethylene |
| Flooded | No not flooded over braid |
| Bulk cable weight | 33 lbs/1000ft |
| Plenum number | 89259 |
Electrical Characteristics
| Nom. velocity of prop. | 78% |
|---|---|
| Nom. capacitance Cond-to-Shield | 17.3 pF/ft (56.8 pF/m) |
| Nom. conductor DCR | 15 Ohm/1000ft |
| Nom. outer shield DCR | 2.6 Ohm/1000ft (8.5 Ohm/km) |
Attenuation (dB/100ft)
| Attenuation 1 MHz | 0.3 dB/100ft |
|---|---|
| Attenuation 5 MHz | 0.65 dB/100ft |
| Attenuation 10 MHz | 0.9 dB/100ft |
| Attenuation 50 MHz | 2.1 dB/100ft |
| Attenuation 100 MHz | 3 dB/100ft |
| Attenuation 200 MHz | 4.5 dB/100ft |
| Attenuation 400 MHz | 6.6 dB/100ft |
| Attenuation 700 MHz | 8.9 dB/100ft |
| Attenuation 900 MHz | 10.1 dB/100ft |
| Attenuation 1000 MHz | 10.9 dB/100ft |
Environmental & Mechanical Ratings
| Operating temperature | -40°C to +80°C |
|---|---|
| Installation min. bend radius | 2.4 in (61 mm) |
| Max. pull tension | 65 lbs (29 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor, Aerial - Black only, When supported by messenger Wire |
| Outdoor | Yes is outdoor grade material |
Compliance & Certifications
| NEC / UL compliance | CM |
|---|---|
| CEC / C(UL) compliance | CM |
| Fire rating | General Purpose (CM, CMG, CMX) |
| Flammability / reaction to fire | UL1685 UL Loading |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
Belden 9259 010 Applications
- Supports standard analog video signal transmission.
- Works for indoor installations requiring CM and AWM 1354 compliance.
- Enables aerial runs in Black only when supported by messenger Wire.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| Overall cable diameter (nominal) | 0.240 in (6.10 mm) |
| Conductor nom. diameter | 0.029 in |
| Nom. insulation diameter | 0.146 in (3.71 mm) |
| Dielectric Material | FPE-Foamed (Cellular) Polyethylene |
| Flooded | No not flooded over braid |
| Bulk cable weight | 33 lbs/1000ft |
| Plenum number | 89259 |
| Nom. velocity of prop. | 78% |
| Nom. capacitance (Cond-to-Shield) | 17.3 pF/ft (56.8 pF/m) |
| Nom. conductor DCR | 15 Ohm/1000ft |
| Nom. outer shield DCR | 2.6 Ohm/1000ft (8.5 Ohm/km) |
| Attenuation @ 1 MHz | 0.3 dB/100ft |
| Attenuation @ 5 MHz | 0.65 dB/100ft |
| Attenuation @ 10 MHz | 0.9 dB/100ft |
| Attenuation @ 50 MHz | 2.1 dB/100ft |
| Attenuation @ 100 MHz | 3 dB/100ft |
| Attenuation @ 200 MHz | 4.5 dB/100ft |
| Attenuation @ 400 MHz | 6.6 dB/100ft |
| Attenuation @ 700 MHz | 8.9 dB/100ft |
| Attenuation @ 900 MHz | 10.1 dB/100ft |
| Attenuation @ 1000 MHz | 10.9 dB/100ft |
| Operating temperature | -40°C to +80°C |
| Installation min. bend radius | 2.4 in (61 mm) |
| Max Pull Tension | 65 lbs (29 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor, Aerial - Black only, When supported by messenger Wire |
| Outdoor | Yes is outdoor grade material |
| NEC / UL compliance | CM |
| CEC / C(UL) compliance | CM |
| Fire rating | General Purpose (CM, CMG, CMX) |
| Flammability / reaction to fire | UL1685 UL Loading |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Priced Per | FT |