Belden 9451P 009U, 22 AWG 1P Shielded FEP LS PVC Jacket CMP ROHS

SKU:Belden 9451P 009U
● Auf Lager
Beschreibung
Belden 9451P 009U is a line level audio cable designed for low voltage analog signals and control in indoor plenum spaces. It features 1 pair of 22 AWG (7x30) TC - Tinned Copper conductors, FEP - Fluorinated Ethylene Propylene insulation, and an overall Beldfoil® Shield. The Flamarrest® Jacket (PVC - Polyvinyl Chloride) and bonded foil shield support efficient stripping on automatic equipment. Electrical performance includes 18.2 Ohm/1000ft (59.7 Ohm/km) Nom. Conductor DCR, 35 pF/ft (110 pF/m) Nom. capacitance Cond-to-Cond, and a 300 V (CMP) UL Voltage Rating.
Belden 9451P 009U Key Features
- 1 pair construction with 22 AWG (7x30) TC - Tinned Copper conductors.
- FEP - Fluorinated Ethylene Propylene insulation with Black & Red color code.
- Overall Beldfoil® Shield (Tape) with Bi-Laminate (Alum+Poly) material and 100% coverage.
- Bonded jacket and shield design for removal on automatic stripping equipment; Drain Wire is inside Foil Shield.
- Flamarrest® Jacket made from PVC - Polyvinyl Chloride.
- Environmental suitability listed as Indoor - Plenum, Indoor.
- NEC / UL compliance: Article 800, CMP; CEC / C(UL) compliance: CMP.
- Flammability / reaction to fire: NFPA 262 (UL910), FT6, IEC 60332-1-2.
- CPR compliance: CPR Euroclass: Eca.
- European directive compliance: EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE).
- UK regulation compliance: UKCA Mark.
- APAC compliance: China RoHS II (GB/T 26572-2011).
Belden 9451P 009U Technical Specs
Electrical & Conductor Specs
| Max. current | 4.4 Amps per Conductor @ 25°C |
|---|---|
| Drainwire type | 22 AWG (7x30) TC |
| Shield DCR (Nom outer) | 13.93 Ohm/1000ft (45.70 Ohm/km) |
Physical Dimensions
| Insulation thickness (Nom.) | 0.008 in (0.20 mm) |
|---|---|
| Insulation diameter (Nom.) | 0.044 in (1.1 mm) |
| Jacket thickness (Nom.) | 0.017 in (0.43 mm) |
| Overall diameter (Nom.) | 0.127 in (3.23 mm) |
| Bulk cable weight | 14 lbs/1000ft (21 kg/km) |
Performance & Electrical Characteristics
| Capacitance Cond-to-other (Nom.) | 67 pF/ft (220 pF/m) |
|---|---|
| Inductance (Nom.) | 0.15 μH/ft (0.49 μH/m) |
| Delay (Nom.) | 1.47 ns/ft |
| Velocity of prop. (Nom.) | 69% |
Environmental & Mechanical Ratings
| UL temperature | 60°C |
|---|---|
| Operating temperature | -20°C to +75°C |
| Stationary min. bend radius | 1.3 in (33 mm) |
| Installation min. bend radius | 1.3 in (33 mm) |
| Max. pull tension | 27 lbs (12 kg) |
Additional Identifiers
| Non-plenum number | 9451 |
|---|
Belden 9451P 009U Applications
- Use it for line level audio connections where consistent signal transfer is needed.
- Run it for low voltage analog signals and control in indoor plenum spaces.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Max. current | 4.4 Amps per Conductor @ 25°C |
| Drainwire type | 22 AWG (7x30) TC |
| Shield DCR (Nom outer) | 13.93 Ohm/1000ft (45.70 Ohm/km) |
| Insulation thickness (nom.) | 0.008 in (0.20 mm) |
| Insulation diameter (nom.) | 0.044 in (1.1 mm) |
| Jacket thickness (nom.) | 0.017 in (0.43 mm) |
| Overall diameter (Nom.) | 0.127 in (3.23 mm) |
| Bulk cable weight | 14 lbs/1000ft (21 kg/km) |
| Capacitance, Cond-to-other (nom.) | 67 pF/ft (220 pF/m) |
| Inductance (nom.) | 0.15 µH/ft (0.49 µH/m) |
| Delay (nom.) | 1.47 ns/ft |
| Velocity of prop. (nom.) | 69% |
| UL temperature | 60°C |
| Operating temperature | -20°C to +75°C |
| Stationary min. bend radius | 1.3 in (33 mm) |
| Installation min. bend radius | 1.3 in (33 mm) |
| Max Pull Tension | 27 lbs (12 kg) |
| Non-Plenum number | 9451 |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.