Belden 9451SB 010, Multi Conductor Shipboard Cable 2C 22 AWG PP

SKU:Belden 9451SB 010
● Auf Lager
Beschreibung
Belden 9451SB 010 is a shipboard-rated, foil-shielded line level audio cable designed for low voltage analog signals and control in shipboard and offshore environments. It is built with 1 pair of 22 AWG (7x30) TC - Tinned Copper conductors, PP - Polypropylene insulation, and an overall Beldfoil® shield with a 22 AWG (7x30) TC drain wire inside the foil shield. The LSZH - Low Smoke Zero Halogen (Flame Retardant) jacket and CMG-LS rating support installations where low smoke and zero halogen materials are required. The cable is shipboard ABS type approved.
Belden 9451SB 010 Key Features
- Shipboard-rated, foil-shielded line level audio cable for low voltage analog signals and control in shipboard and offshore environments.
- 1 pair of 22 AWG (7x30) TC - Tinned Copper conductors.
- PP - Polypropylene insulation with color code: Black & Red.
- Overall shield: Beldfoil® with 100% coverage and shield material: Bi-Laminate (Alum+Poly).
- 22 AWG (7x30) TC drain wire inside foil shield to support grounding.
- Jacket material: LSZH - Low Smoke Zero Halogen (Flame Retardant).
- NEC / UL compliance: Article 800, CMG-LS, including UL voltage rating: 300 V (CMG-LS) and UL temperature: 105°C.
- Marine compliance: ABS Type Approval Certificate 05-HS500072B.
Belden 9451SB 010 Technical Specs
Construction & Physical Specs
| Number of conductors | 1 Pair |
|---|---|
| Conductor size | 22 AWG |
| Stranding | 7x30 |
| Conductor material | TC - Tinned Copper |
| Insulation material | PP - Polypropylene |
| Insulation thickness (nom.) | 0.009 in (0.23 mm) |
| Insulation diameter (nom.) | 0.046 in (1.2 mm) |
| Shield type | Tape |
| Jacket thickness (nom.) | 0.033 in (0.84 mm) |
| Overall cable diameter (nominal) | 0.160 in (4.06 mm) |
| Bulk cable weight | 18 lbs/1000ft |
Electrical Characteristics
| Nom. conductor DCR | 18.2 Ohm/1000ft |
|---|---|
| Nom outer shield DCR | 20.63 Ohm/1000ft (67.68 Ohm/km) |
| Nom. capacitance cond-to-cond | 35 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 67 pF/ft (220 pF/m) |
| Nom. characteristic impedence | 45 Ohm |
| Nom. delay | 1.5 ns/ft |
| Nom. inductance | 0.17 μH/ft (0.56 μH/m) |
| Nom. velocity of prop. | 66% |
| Max. current | 4.4 Amps per Conductor @ 25°C |
Environmental & Mechanical Ratings
| Operating temperature | -30°C to +105°C |
|---|---|
| Bend radius (stationary min.) | 1.6 in (41 mm) |
| Bend radius (installation min.) | 1.6 in (41 mm) |
| Max. pull tension | 27 lbs (12 kg) |
| Environmental suitability | Indoor/Outdoor, Indoor |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202, IEC 60332-1-2, IEC 60332-3-22 |
| CPR compliance | CPR Euroclass: Dca-s2,d1,a1 |
Compliance & Certifications
| CEC / C(UL) compliance | CMG-ST1 |
|---|---|
| IEEE compliance | Std. 45 clause 23 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 9451SB 010 Applications
- Use it in shipboard and offshore environments where shipboard-rated cabling is required.
- Support line level audio connections in installations that need a foil-shielded construction for noise rejection.
- Deploy it for low voltage analog signals and control circuits in marine and offshore settings.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Number of Conductors | 1 Pair |
| Conductor size | 22 AWG |
| Stranding | 7x30 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PP - Polypropylene |
| Insulation thickness (nom.) | 0.009 in (0.23 mm) |
| Insulation diameter (nom.) | 0.046 in (1.2 mm) |
| Shield Type | Tape |
| Jacket thickness (nom.) | 0.033 in (0.84 mm) |
| Overall cable diameter (nominal) | 0.160 in (4.06 mm) |
| Bulk cable weight | 18 lbs/1000ft |
| Nom. conductor DCR | 18.2 Ohm/1000ft |
| Nom. outer shield DCR | 20.63 Ohm/1000ft (67.68 Ohm/km) |
| Nom. capacitance cond-to-cond | 35 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 67 pF/ft (220 pF/m) |
| Nom. characteristic impedence | 45 Ohm |
| Nom. delay | 1.5 ns/ft |
| Nom. inductance | 0.17 µH/ft (0.56 µH/m) |
| Nom. velocity of prop. | 66% |
| Max. current | 4.4 Amps per Conductor @ 25°C |
| Operating temperature | -30°C to +105°C |
| Bend radius (stationary min.) | 1.6 in (41 mm) |
| Bend radius (installation min.) | 1.6 in (41 mm) |
| Max Pull Tension | 27 lbs (12 kg) |
| Environmental suitability | Indoor/Outdoor, Indoor |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202, IEC 60332-1-2, IEC 60332-3-22 |
| CPR compliance | CPR Euroclass: Dca-s2,d1,a1 |
| CEC / C(UL) compliance | CMG-ST1 |
| IEEE compliance | Std. 45 clause 23 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.