Belden 9460 060U, Multi Pair Cable 1 Pair 18 AWG PE PVC Jacket

SKU:Belden 9460 060U
● Auf Lager
Beschreibung
Belden 9460 060U is a 1 pair 18 AWG control, instrumentation, and audio cable designed for low-voltage signal transmission in panel wiring, computer communication, and line level audio. It features 18AWG (16x30) tinned copper conductors with PE insulation and an overall Beldfoil® shield for noise rejection. A PVC outer jacket with CM rating supports indoor general-purpose installations, while the bonded jacket and shield are designed to strip cleanly on automatic stripping equipment.
Belden 9460 060U Key Features
- The 1 pair 18 AWG construction supports control, instrumentation, and audio signal wiring.
- 18AWG (16x30) tinned copper conductors with PE insulation.
- An overall Beldfoil® shield provides noise rejection.
- The bonded jacket and shield help enable clean removal on automatic stripping equipment.
- Foil-in construction positions the drain wire on the inside of the shield.
- A PVC outer jacket with CM rating supports indoor general-purpose installations.
Belden 9460 060U Technical Specs
Construction & Materials
| Number of pairs | 1 |
|---|---|
| Conductor size | 18 AWG |
| Stranding | 16x30 |
| Conductor material | TC - Tinned Copper |
| Insulation material | PE - Polyethylene |
| Nom. thickness (insulation) | 0.018 in (0.46 mm) |
| Nom. insulation diameter | 0.082 in (2.1 mm) |
| Color code | Black & Clear |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield coverage | 100% |
| Drainwire type | 20 AWG (7x28) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Nom. thickness (jacket) | 0.030 in (0.76 mm) |
Physical Dimensions & Weight
| Nom. diameter | 0.230 in (5.84 mm) |
|---|---|
| Overall cable diameter (nominal) | 0.230 in (5.84 mm) |
| Bulk cable weight | 34 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. conductor DCR | 6.5 Ohm/1000ft |
|---|---|
| Nom. capacitance cond-to-cond | 29.8 pF/ft (97.8 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 44 pF/ft (140 pF/m) |
| Nom. characteristic impedence | 57 Ohm |
| Nom. inductance | 0.18 μH/ft (0.59 μH/m) |
| Max. current | 5.2 Amps per Conductor at 25ºC |
| UL voltage rating | 300 V (CM) |
Environmental & Mechanical Ratings
| UL temperature | 60°C |
|---|---|
| Operating temperature | -20°C to +60°C |
| Bend radius (stationary min.) | 2.3 in (58 mm) |
| Bend radius (installation min.) | 2.3 in (58 mm) |
| Max. pull tension | 62 lbs (28 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
Compliance & Certifications
| NEC / UL compliance | Article 800, CM |
|---|---|
| CEC / C(UL) compliance | CM |
| CPR compliance | CPR Euroclass: Eca |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 9460 060U Applications
- Use it with automatic stripping equipments where clean jacket and shield removal is needed.
- Support low voltage analog signals (4-20ma, 0-10v, ...) in control and instrumentation circuits.
- Use it for low voltage digital control (24v, …) in automation and control wiring.
- Connect line level audio signals.
- Fit computer communication signal wiring where shielded signal cable is required.
- Install it for panel wiring in indoor installations.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Number of pairs | 1 |
| Conductor size | 18 AWG |
| Stranding | 16x30 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PE - Polyethylene |
| Nom. thickness (insulation) | 0.018 in (0.46 mm) |
| Nom. insulation diameter | 0.082 in (2.1 mm) |
| Color Code | Black & Clear |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 20 AWG (7x28) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Nom. thickness (jacket) | 0.030 in (0.76 mm) |
| Nom. diameter | 0.230 in (5.84 mm) |
| Overall cable diameter (nominal) | 0.230 in (5.84 mm) |
| Bulk cable weight | 34 lbs/1000ft |
| Nom. conductor DCR | 6.5 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 29.8 pF/ft (97.8 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 44 pF/ft (140 pF/m) |
| Nom. characteristic impedence | 57 Ohm |
| Nom. inductance | 0.18 µH/ft (0.59 µH/m) |
| Max. current | 5.2 Amps per Conductor at 25ºC |
| UL Voltage Rating | 300 V (CM) |
| UL temperature | 60°C |
| Operating temperature | -20°C to +60°C |
| Bend radius (stationary min.) | 2.3 in (58 mm) |
| Bend radius (installation min.) | 2.3 in (58 mm) |
| Max Pull Tension | 62 lbs (28 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
| NEC / UL compliance | Article 800, CM |
| CEC / C(UL) compliance | CM |
| CPR compliance | CPR Euroclass: Eca |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.