Belden 9464 060U, Multi Pair Cable 1 Pair 20 AWG PE PVC Jacket

SKU:Belden 9464 060U
● Auf Lager
Beschreibung
Belden 9464 060U is a 1 pair, 20 AWG multi-conductor cable for low-voltage signal and control applications. It features 2 stranded 20 AWG (7x28) TC - Tinned Copper conductors with PE - Polyethylene insulation, plus an overall shield and drain for noise rejection. A PVC - Polyvinyl Chloride outer jacket and NEC / UL compliance: Article 800, CM support general-purpose installations such as panel wiring, computer communication, and line level audio.
Belden 9464 060U Key Features
- 1 pair construction with 2 stranded 20 AWG (7x28) TC - Tinned Copper conductors for low-voltage signal and control wiring.
- Overall shield & drain using tape with Bi-Laminate (Alum+Poly) and 100% coverage to help reduce noise in signal paths.
- Drainwire type: 20 AWG (7x28) TC for a consistent shield termination point.
- PE - Polyethylene insulation and a PVC - Polyvinyl Chloride outer jacket for general-purpose cable construction.
- NEC / UL compliance: Article 800, CM and UL voltage rating: 300 V for specified installation and electrical requirements.
Belden 9464 060U Technical Specs
Construction & Materials
| Number of conductors | 2 |
|---|---|
| Conductor size | 20 AWG (American Wire Gauge) |
| Conductor stranding | 7x28 |
| Conductor material | TC - Tinned Copper |
| Conductor type | Stranded Conductor |
| Insulation material | PE - Polyethylene |
| Color code | Black, White |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Shield | Yes |
| Shield construction | Overall Shield & drain |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
Dimensions & Weight
| Nom. thickness (Insulation) | 0.016 in (0.41 mm) |
|---|---|
| Nom. insulation diameter | 0.70 in (18 mm) |
| Nom. thickness (Jacket) | 0.035 in (0.89 mm) |
| Nom. diameter | 0.214 in (5.44 mm) |
| Bulk cable weight | 30 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. conductor DCR | 11.1 Ohm/1000ft |
|---|---|
| Nom outer shield DCR | 7.51 Ohm/1000ft (24.6 Ohm/km) |
| Nom. capacitance Cond-to-Cond | 27 pF/ft (89 pF/m) |
| Nom. capacitance Cond-to-other (conds + Shield) | 49 pF/ft (160 pF/m) |
| Nom. characteristic impedence | 56 Ohm |
| Nom. inductance | 0.18 μH/ft (0.59 μH/m) |
| Max. current | 3.9 Amps per Conductor at 20ºC |
Environmental & Mechanical Ratings
| Environmental suitability | Indoor, Outdoor |
|---|---|
| UL temperature | 60°C |
| Operating | -20°C To +60°C |
| Stationary min. bend radius | 2.14 in (54.4 mm) |
| Installation min. bend radius | 2.14 in (54.4 mm) |
| Max. pull tension | 31.2 lbs (14.2 kg) |
Compliance & Certifications
| CEC / C(UL) compliance | CM |
|---|---|
| AWM compliance | AWM 2092 |
| Flammability / reaction to fire | UL1685 UL Loading |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 9464 060U Applications
- Use it for automatic stripping equipments where consistent handling and termination are needed.
- Support low voltage analog signals (4-20ma, 0-10v, ...) in signal and control circuits.
- Handle low voltage digital control (24v, …) for common control and automation signaling.
- Choose it for line level audio connections where signal integrity is important.
- Install it in computer communication wiring where shielded signal cabling is required.
- Apply it to panel wiring for general-purpose control and signal distribution.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Number of Conductors | 2 |
| Conductor size | 20 AWG (American Wire Gauge) |
| Conductor stranding | 7x28 |
| Conductor Material | TC - Tinned Copper |
| Conductor Type | Stranded Conductor |
| Insulation Material | PE - Polyethylene |
| Color Code | Black, White |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Shield | Yes |
| Shield construction | Overall Shield & drain |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Nom. thickness (insulation) | 0.016 in (0.41 mm) |
| Nom. insulation diameter | 0.70 in (18 mm) |
| Nom. thickness (jacket) | 0.035 in (0.89 mm) |
| Nom. diameter | 0.214 in (5.44 mm) |
| Bulk cable weight | 30 lbs/1000ft |
| Nom. conductor DCR | 11.1 Ohm/1000ft |
| Nom. outer shield DCR | 7.51 Ohm/1000ft (24.6 Ohm/km) |
| Nom. capacitance cond-to-cond | 27 pF/ft (89 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 49 pF/ft (160 pF/m) |
| Nom. characteristic impedence | 56 Ohm |
| Nom. inductance | 0.18 µH/ft (0.59 µH/m) |
| Max. current | 3.9 Amps per Conductor at 20ºC |
| Environmental suitability | Indoor, Outdoor |
| UL temperature | 60°C |
| Operating | -20°C To +60°C |
| Stationary min. bend radius | 2.14 in (54.4 mm) |
| Installation min. bend radius | 2.14 in (54.4 mm) |
| Max Pull Tension | 31.2 lbs (14.2 kg) |
| CEC / C(UL) compliance | CM |
| AWM compliance | AWM 2092 |
| Flammability / reaction to fire | UL1685 UL Loading |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.