Belden 9488 010, Power Limited Tray Cable 1 Pair 14 AWG 600V PVC, Black Jacket

SKU:Belden 9488 010
● Auf Lager
Beschreibung
Belden 9488 010 is a VNTC CONTROL Power Limited Tray Cable built with 1 pair (2 conductor) 14 AWG (41x30) TC - Tinned Copper conductors and a black PVC - Polyvinyl Chloride jacket. This unshielded, twisted-pair cable uses PVC/Nylon - Polyvinyl Chloride + Nylon insulation with a Black, Red color code. It is rated 600 V (TC), 150 V (NPLF) and supports wet/dry operation from -30°C to 90°C. Designed for indoor and outdoor use, it includes sunlight resistance, burial suitability, and a ripcord for easier jacket removal.
Belden 9488 010 Key Features
- VNTC CONTROL product type with 1 pair (2 conductor) construction for instrumentation and control wiring.
- 14 AWG stranded conductors with 41x30 stranding and TC - Tinned Copper conductor material.
- Unshielded twisted-pair design with PVC/Nylon - Polyvinyl Chloride + Nylon insulation and Black, Red color code.
- Black PVC - Polyvinyl Chloride outer jacket with a ripcord for easier jacket removal.
- UL voltage rating of 600 V (TC), 150 V (NPLF).
- Environmental suitability includes indoor, outdoor, sunlight resistance, burial.
Belden 9488 010 Technical Specs
Construction & Build
| Pairs | 1 |
|---|---|
| Number of Conductors | 2 Conductor |
| Conductor Type | Stranded |
| Shield | No Shield |
| Armor | No |
| Composite | No |
| Earth/Ground Wires | No |
Physical Dimensions
| Insulation Thickness (Nom.) | 0.023 in (0.58 mm) |
|---|---|
| Insulation Diameter (Nom.) | 0.119 in (3.02 mm) |
| Jacket Thickness (Nom.) | 0.048 in (1.2 mm) |
| Overall Diameter (Nom.) | 0.359 in (9.12 mm) |
| Bulk Cable Weight | 70 lbs/1000ft |
Performance & Electrical Characteristics
| Conductor DCR (Nom.) | 2.6 Ohm/1000ft |
|---|---|
| Capacitance Cond-to-Cond (Nom.) | 50 pF/ft (160 pF/m) |
| Inductance (Nom.) | 0.24 μH/ft (0.79 μH/m) |
| Max. Current | 26 Amps per Conductor at 25ºC |
Environmental & Mechanical Ratings
| UL Temperature | 90°C Dry, 90°C Wet |
|---|---|
| Operating (Wet/Dry) | -30°C to 90°C |
| Stationary Min. Bend Radius | 1.4 in (36 mm) |
| Installation Min. Bend Radius | 1.75 in (44.5 mm) |
| Max. Pull Tension | 107 lbs (48.5 kg) |
| Flammability / Reaction to Fire | UL 1685 UL loading, IEEE 1202 FT4 |
Compliance & Certifications
| NEC / UL Compliance | Article 336, Article 760, NPLF, TC, THWN-2 |
|---|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
Belden 9488 010 Applications
- Use it in industrial control systems where reliable signal and control wiring is required.
- Route it through raceways, cable trays, and ducts in industrial installations.
- Support digital control and distributed control circuits in control and instrumentation setups.
- Apply it in instrument circuits such as Instruments (4-20ma, 0-10v, ...) and low voltage digital control (24v, …).
- Specify it for encoders and other control circuits where a twisted-pair instrumentation cable is required.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Pairs | 1 |
| Number of Conductors | 2 Conductor |
| Conductor Type | Stranded |
| Shield | No Shield |
| Armor | No |
| Composite | No |
| Earth/ground wires | No |
| Insulation thickness (nom.) | 0.023 in (0.58 mm) |
| Insulation diameter (nom.) | 0.119 in (3.02 mm) |
| Jacket thickness (nom.) | 0.048 in (1.2 mm) |
| Overall diameter (Nom.) | 0.359 in (9.12 mm) |
| Bulk cable weight | 70 lbs/1000ft |
| Conductor DCR (nom.) | 2.6 Ohm/1000ft |
| Capacitance, Cond-to-Cond (nom.) | 50 pF/ft (160 pF/m) |
| Inductance (nom.) | 0.24 µH/ft (0.79 µH/m) |
| Max. current | 26 Amps per Conductor at 25ºC |
| UL temperature | 90°C Dry, 90°C Wet |
| Operating (wet/dry) | -30°C to 90°C |
| Stationary min. bend radius | 1.4 in (36 mm) |
| Installation min. bend radius | 1.75 in (44.5 mm) |
| Max Pull Tension | 107 lbs (48.5 kg) |
| Flammability / reaction to fire | UL 1685 UL loading, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, Article 760, NPLF, TC, THWN-2 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.