Belden 9502 060, Multi Conductor Computer Cable 2 pair 24 AWG PVC

SKU:Belden 9502 060
● Auf Lager
Beschreibung
Belden 9502 060 is a 2 twisted pair computer EIA RS-232 cable with 24 AWG stranded (7x32) TC - Tinned Copper conductors, semi-rigid PVC insulation, and a PVC jacket. It features an overall Beldfoil® shield (100% coverage) with a 24 AWG (7x32) TC drainwire to help reduce EMI in noise-sensitive installations. The cable has a nominal 0.222 in (5.64 mm) overall diameter and is designed for indoor use.
Belden 9502 060 Key Features
- 2 twisted pair computer EIA RS-232 cable construction for data and control signal wiring.
- 24 AWG stranded (7x32) TC - Tinned Copper conductors.
- Semi-rigid PVC insulation (SR-PVC - Polyvinyl Chloride (Semi-Rigid)).
- Overall Beldfoil® shield with 100% coverage and a 24 AWG (7x32) TC drainwire.
- PVC - Polyvinyl Chloride jacket with a nominal 0.222 in (5.64 mm) overall diameter.
- UL voltage rating: 300 V (CMG), 300 V (UL AWM 2464).
- Operating temperature: -30°C to +80°C.
- Environmental suitability: indoor.
Belden 9502 060 Technical Specs
Construction & Materials
| Pairs | 2 |
|---|---|
| Conductor size | 24 AWG |
| Conductor stranding | 7x32 |
| Conductor material | TC - Tinned Copper |
| Color code | Black & Red, Black & White |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 24 AWG (7x32) TC |
Physical Dimensions
| Insulation thickness (nom.) | 0.011 in (0.28 mm) |
|---|---|
| Insulation diameter (nom.) | 0.044 in (1.1 mm) |
| Jacket thickness (nom.) | 0.032 in (0.81 mm) |
Performance & Electrical Characteristics
| Nom. Conductor DCR | 28.8 Ohm/1000ft |
|---|---|
| Nom. capacitance Cond-to-Cond | 30 pF/ft (98 pF/m) |
| Nom. capacitance Cond-to-other (conds + Shield) | 50 pF/ft (160 pF/m) |
| Nom. inductance | 0.19 μH/ft (0.62 μH/m) |
| Nom. velocity of prop. | 60% |
| Max. current | 2.1 Amps per Conductor at 25ºC |
| Nom outer Shield DCR | 16.19 Ohm/1000ft (53.12 Ohm/km) |
Environmental & Mechanical Ratings
| UL temperature | 80°C |
|---|---|
| Bend radius (stationary min.) | 2.2 in (56 mm) |
| Bend radius (installation min.) | 2.2 in (56 mm) |
| Max. pull tension | 27.5 lbs (12.5 kg) |
| Bulk cable weight | 26 lbs/1000ft |
Compliance & Certifications
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4 |
|---|---|
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| NEC / UL compliance | Article 800, CMG |
| AWM compliance | AWM 2464, AWM I/II A |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-MSHA-SC-7K-182037 |
| Plenum number | 82502 |
Belden 9502 060 Applications
- RS-232 applications are commonly supported where consistent low-voltage signal transmission is required.
- Computer communications links can be supported in installations that require a shielded twisted-pair construction.
- Control and instrumentation wiring often uses low voltage analog signals (4-20ma, 0-10v, ...).
- Equipment and systems can support low voltage digital control (24v, …) connections for control signaling.
- Noise-sensitive routing can use line level audio runs where a shielded cable is preferred.
- Organized internal routing and terminations are commonly supported in panel wiring.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Pairs | 2 |
| Conductor size | 24 AWG |
| Conductor stranding | 7x32 |
| Conductor Material | TC - Tinned Copper |
| Color Code | Black & Red, Black & White |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 24 AWG (7x32) TC |
| Insulation thickness (nom.) | 0.011 in (0.28 mm) |
| Insulation diameter (nom.) | 0.044 in (1.1 mm) |
| Jacket thickness (nom.) | 0.032 in (0.81 mm) |
| Nom. conductor DCR | 28.8 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 30 pF/ft (98 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 50 pF/ft (160 pF/m) |
| Nom. inductance | 0.19 µH/ft (0.62 µH/m) |
| Nom. velocity of prop. | 60% |
| Max. current | 2.1 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 16.19 Ohm/1000ft (53.12 Ohm/km) |
| UL temperature | 80°C |
| Bend radius (stationary min.) | 2.2 in (56 mm) |
| Bend radius (installation min.) | 2.2 in (56 mm) |
| Max Pull Tension | 27.5 lbs (12.5 kg) |
| Bulk cable weight | 26 lbs/1000ft |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| NEC / UL compliance | Article 800, CMG |
| AWM compliance | AWM 2464, AWM I/II A |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-MSHA-SC-7K-182037 |
| Plenum number | 82502 |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.