Belden 9841 060 RS485 1 Paar #24 Str TC PVC CM specifications
AttributeValue
Pairs1
Conductor size24 AWG
Stranding7x32
Conductor MaterialTC - Tinned Copper
Insulation MaterialPE - Polyethylene
Insulation nom. thickness0.023 in (0.58 mm)
Nom. insulation diameter0.068 in (1.7 mm)
Color CodeWhite/Blue Stripe & Blue/White Stripe
Overall shieldBeldfoil® + Tinned Copper braid
Tape shield materialBi-Laminate (Alum+Poly)
Tape coverage100%
Braid shield materialTinned Copper (TC)
Braid coverage90%
Drainwire type24 AWG (7x32) TC
Jacket MaterialPVC - Polyvinyl Chloride
Jacket ColorChrome
Jacket nom. thickness0.035 in (0.89 mm)
Nom. diameter0.232 in (5.89 mm)
Overall cable diameter (nominal)0.232 in (5.89 mm)
Jacket OD +/-0.020
Nom. characteristic impedence120 Ohm
Nom. conductor DCR24 Ohm/1000ft (79 Ohm/km)
Nom. outer shield DCR3.4 Ohm/1000ft (11 Ohm/km)
Nom. capacitance cond-to-cond12.8 pF/ft (42.0 pF/m)
Nom. capacitance cond-to-other (conds + Shield)23 pF/ft (75 pF/m)
Nom. delay1.6 ns/ft
Nom. velocity of prop.66%
Max. current2.1 Amps per Conductor at 25ºC (10°C Temperature Rise)
Nom. insertion loss (attenuation) [dB/100ft]0.6 at 1 MHz
UL Voltage Rating300 V (CM), 30 V (UL AWM 2919)
Environmental suitabilityIndoor
Operating temperature-30°C to +80°C
UL temperature80°C
Bend radius (stationary min.)2.5 in (64 mm)
Bend radius (installation min.)2.5 in (64 mm)
Max Pull Tension72.3 lbs (32.8 kg)
Bulk cable weight36 lbs/1000ft (54 kg/km)
Overall cabling lay length2.5 Inch
Overall cabling lay directionLeft hand
Overall cabling lay twists4.8 twist/ft
NEC / UL complianceArticle 800, CM
CEC / C(UL) complianceCM
AWM complianceAWM 2919
Flammability / reaction to fireUL 1685 UL Loading, IEC 60332-1-2
CPR complianceCPR Euroclass: Eca; CPR UKCA Class: Eca
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
Other standard compliance(s)DMX-512
Plenum number82841, 89841
Non-Plenum number9841ZH
Item TypeBelden Multi-Pair Cable
Other Part Numbers9841 060100, 9841 060250, 9841 060500, 9841 0601000
Priced PerFT

Dokumente

Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.

Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?

Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.