Belden BAV 1525A 010, Coax CATV Cable 14 AWG SH LDPE Black

SKU:Belden 1525A 010
● Auf Lager
Beschreibung
Belden BAV 1525A 010 is a Series 11 broadband coax cable (RG 11) built with a 14 AWG solid BCCS - Bare Copper Covered Steel conductor and PE - Polyethylene (Foam) insulation. It uses a dual-layer shield system combining Duobond® II tri-laminate tape (100%) with a 60% aluminum braid, and it is waterblocked with grease. This 75 Ohm coax is rated 300 V and is specified for Outdoor - Water Exposure, Outdoor, UV Resistance, Aerial - When supported by messenger Wire, and Burial environments.
Key Features
- Series 11 broadband coax cable (RG 11) for CATV, RF drop cable, and Over-The-Air (OTA) antenna connections.
- 14 AWG solid BCCS - Bare Copper Covered Steel conductor.
- PE - Polyethylene (Foam) insulation with White color code.
- Dual-layer shielding: Duobond® II tri-laminate tape (Alum+Poly+Alum) at 100% coverage plus 60% aluminum braid.
- Waterblocking: Grease.
- 75 Ohm nominal characteristic impedance; voltage rating: 300 V.
- Environmental suitability: Outdoor - Water Exposure, Outdoor, UV Resistance, Aerial - When supported by messenger Wire, Burial.
Technical Specs
Physical Construction
| Overall cable diameter (nominal) | 0.393 in (9.98 mm) |
|---|---|
| Conductor nom. diameter | 0.064 in |
| Nom. insulation diameter | 0.280 in (7.11 mm) |
| Jacket material | PE - Polyethylene |
| Bulk cable weight | 44 lbs/1000ft (65 kg/km) |
Electrical Characteristics
| Nom. velocity of prop. | 83% |
|---|---|
| Nom. capacitance cond-to-shield | 16.3 pF/ft (53.5 pF/m) |
| Nom. conductor DCR | 12 Ohm/1000ft |
| Nom. outer shield DCR | 4.1 Ohm/1000ft (13 Ohm/km) |
Performance
| Return loss frequency | 5 - 1000 MHz |
|---|---|
| Min. structural return loss | 20 dB |
| Attenuation (Max.) | 5 MHz: 0.38 dB/100ft; 55 MHz: 0.96 dB/100ft; 211 MHz: 1.90 dB/100ft; 250 MHz: 2.05 dB/100ft; 270 MHz: 2.13 dB/100ft; 300 MHz: 2.25 dB/100ft; 330 MHz: 2.35 dB/100ft; 350 MHz: 2.42 dB/100ft; 400 MHz: 2.47 dB/100ft; 450 MHz: 2.75 dB/100ft; 500 MHz: 2.90 dB/100ft; 550 MHz: 3.04 dB/100ft; 600 MHz: 3.18 dB/100ft; 750 MHz: 3.65 dB/100ft; 870 MHz: 3.84 dB/100ft; 1000 MHz: 4.35 dB/100ft |
Environmental & Mechanical Ratings
| Operating temperature | -55°C to +80°C |
|---|---|
| Bend radius (installation min.) | 4.5 in (110 mm) |
| Max. pull tension | 199 lbs (90.3 kg) |
Compliance & Certifications
| Other standard compliance(s) | ANSI/SCTE 74 |
|---|---|
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Use in broadband installations that require consistent coax performance across common RF frequencies.
- Support Cable Television (CATV) connections in residential or commercial distribution runs.
- Run RF drop cable to connect service entry points to equipment locations.
- Connect Over-The-Air (OTA) antennas to receiving equipment using a 75 Ohm coax connection.
Belden BAV™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Overall cable diameter (nominal) | 0.393 in (9.98 mm) |
| Conductor nom. diameter | 0.064 in |
| Nom. insulation diameter | 0.280 in (7.11 mm) |
| Jacket Material | PE - Polyethylene |
| Bulk cable weight | 44 lbs/1000ft (65 kg/km) |
| Nom. velocity of prop. | 83% |
| Nom. capacitance (Cond-to-Shield) | 16.3 pF/ft (53.5 pF/m) |
| Nom. conductor DCR | 12 Ohm/1000ft |
| Nom. outer shield DCR | 4.1 Ohm/1000ft (13 Ohm/km) |
| Return loss frequency | 5 - 1000 MHz |
| Min. structural return loss | 20 dB |
| Attenuation (Max.) | 5 MHz: 0.38 dB/100ft; 55 MHz: 0.96 dB/100ft; 211 MHz: 1.90 dB/100ft; 250 MHz: 2.05 dB/100ft; 270 MHz: 2.13 dB/100ft; 300 MHz: 2.25 dB/100ft; 330 MHz: 2.35 dB/100ft; 350 MHz: 2.42 dB/100ft; 400 MHz: 2.47 dB/100ft; 450 MHz: 2.75 dB/100ft; 500 MHz: 2.90 dB/100ft; 550 MHz: 3.04 dB/100ft; 600 MHz: 3.18 dB/100ft; 750 MHz: 3.65 dB/100ft; 870 MHz: 3.84 dB/100ft; 1000 MHz: 4.35 dB/100ft |
| Operating temperature | -55°C to +80°C |
| Bend radius (installation min.) | 4.5 in (110 mm) |
| Max Pull Tension | 199 lbs (90.3 kg) |
| Other standard compliance(s) | ANSI/SCTE 74 |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.