Kontakt1-800-975-3686
Ramcorp Wire & Cable

Belden BAV 1855P 007, Coax Sub Miniature Plenum 23 AWG FFEP SH

Belden BAV 1855P 007, Coax Sub Miniature Plenum 23 AWG FFEP SH

SKU:Belden 1855P 007

$2.35/ FT

Auf Lager

Beschreibung

Spezifikationen

Belden BAV 1855P 007, Coax Sub Miniature Plenum 23 AWG FFEP SH specifications
AttributeValue
Coax constructionCoaxial
Overall cable diameter (nominal)0.159 in (4.04 mm)
FloodedNo, not flooded over braid
Conductor diameter (nom.)0.023 in
Insulation MaterialFEP - Fluorinated Ethylene Propylene (Foam)
Dielectric MaterialFFEP-foamed (cellular)
Nom. insulation diameter0.102 in (2.59 mm)
Color CodeWhite
Outer shield layer 1Tape
Outer Shield layer 1 materialTri-Laminate (Alum+Poly+Alum)
Outer Shield layer 1 coverage100%
Outer shield layer 2Braid
Outer Shield layer 2 coverage95%
Jacket MaterialFlamarrest
OutdoorNo, not outdoor grade material
Bulk cable weight21 lbs/1000ft
Non-Plenum number1855A
Nom. velocity of prop.80%
Nom. capacitance (Cond-to-Shield)16.6 pF/ft (54.5 pF/m)
Nom. conductor DCR20.1 Ohm/1000ft
Nom. outer shield DCR3.7 Ohm/1000ft (12 Ohm/km)
Return loss (5 - 1600 MHz)23 dB
Return loss (1600 - 4500 MHz)21 dB
Return loss (4500 - 6000 MHz)15 dB
Attenuation (nominal) 1 MHz0.38 dB/100ft
Attenuation (Nominal) 3.58 MHz0.76 dB/100ft
Attenuation (nominal) 10 MHz1.3 dB/100ft
Attenuation (Nominal) 71.5 MHz3.1 dB/100ft
Attenuation (Nominal) 135 MHz4.1 dB/100ft
Attenuation (Nominal) 270 MHz5.8 dB/100ft
Attenuation (Nominal) 360 MHz6.9 dB/100ft
Attenuation (Nominal) 540 MHz8.7 dB/100ft
Attenuation (Nominal) 720 MHz10.3 dB/100ft
Attenuation (Nominal) 750 MHz10.5 dB/100ft
Attenuation (nominal) 1000 MHz12.4 dB/100ft
Attenuation (Nominal) 1500 MHz15.7 dB/100ft
Attenuation (Nominal) 2250 MHz19.9 dB/100ft
Attenuation (Nominal) @ 3000 MHz23.8 dB/100ft
Attenuation (Nominal) 4500 MHz30.3 dB/100ft
Attenuation (Nominal) 6000 MHz36.4 dB/100ft
UL temperature75°C
Operating0°C to +75°C
Installation min. bend radius4 in (100 mm)
Max Pull Tension40 lbs (18 kg)
Environmental suitabilityIndoor - Plenum, Indoor
CEC / C(UL) complianceCMP
Flammability / reaction to fireNFPA 262
CPR complianceCPR Euroclass: Eca; CPR UKCA Class: Eca
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
SustainabilityCA Prop 65
Priced PerFT

Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.

Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?

Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.