Belden FSSL012ND, 12 F FX OS2 Outdoor OSP Dry Tube Black Jacket

SKU:Belden FSSL012ND
● Auf Lager
Beschreibung
Belden FSSL012ND is an outdoor, all-dielectric OS2 loose tube fiber optic cable with 12 fibers and a gel-free dry tube design. It uses a PE - Polyethylene jacket in black and includes Waterblock Tape for cable core water blocking. Optical characteristics include max. attenuation of 0.35 dB/km (1310 nm) and 0.25 dB/km (1550 nm). For handling and installation, it maintains a minimum bend radius of 15x Cable OD during installation and 10x Cable OD during operation.
Belden FSSL012ND Key Features
- Outdoor, all-dielectric design with environmental suitability listed as Outdoor, Sunlight Resistance, Burial.
- OS2 fiber with 12 fibers in a loose tube construction and a gel-free subunit waterblocking design.
- PE - Polyethylene jacket in black with a nom. diameter of 0.386 in (9.8 mm).
- Cable core water blocking uses Waterblock Tape to support moisture management in the cable core.
- Max. attenuation is 0.35 dB/km (1310 nm) and 0.25 dB/km (1550 nm).
- Minimum bend radius is 15x Cable OD during installation and 10x Cable OD during operation.
Belden FSSL012ND Technical Specs
Construction & Physical Specs
| Cable Type | Loose tube |
|---|---|
| Number of active subunits | 1 |
| Fibers per subunit | 12 |
| Number of fillers | 4 |
| Subunit Diameter | 0.098 in (2.5 mm) |
| Subunit color | TIA-598-D |
| Fiber core Diameter | 8.2/125 μm |
| Fiber Diameter | 250 μm |
| Fiber color coding | TIA-598-D |
| Central strength member type | GRP |
| Strength member | Waterblocking Fiberglass Yarns |
| Outer Jacket ripcord | 1 |
| Bulk Cable Weight | 59 lbs/kft (88 kg/km) |
| Armored | No |
| Rodent protected | No |
| Self-support | No |
Performance & Optical Characteristics
| Mode field Diameter | 9.2 μm (1310 nm); 10.4 μm (1550 nm) |
|---|---|
| 1 Gigabit Ethernet performance | 5,000 m (1310 nm) |
| 10 Gigabit Ethernet performance | 10,000 m (1310 nm); 40,000 m (1550 nm) |
Mechanical Ratings
| Max. tensile strength during installation | 2670 N (600 lbf) |
|---|---|
| Max. tensile strength during operation | 800 N (180 lbf) |
| Crush resistance | 220 N/cm |
Environmental Ratings
| Installation Temperature Range | -30°C to +60°C |
|---|---|
| Operating Temperature Range | -40°C to +70°C |
| Storage Temperature Range | -40°C to +70°C |
Compliance & Certifications
| ICEA compliance | S-87-640 |
|---|---|
| TIA/EIA compliance | ANSI/ICEA S-87-640 |
| Telcordia compliance | Telcordia GR-20 |
| Sustainability | CA Prop 65 |
Belden FSSL012ND Applications
- Use in Campus Area Network installations where an outdoor fiber backbone is needed across a campus environment.
- Enable long haul links where extended-distance fiber runs are required.
- Provide backbone connectivity to help interconnect network segments over longer routes.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Cable type | Loose tube |
| Number of active subunits | 1 |
| Fibers per subunit | 12 |
| Number of fillers | 4 |
| Subunit diameter | 0.098 in (2.5 mm) |
| Subunit color | TIA-598-D |
| Fiber core diameter | 8.2/125 µm |
| Fiber diameter | 250 µm |
| Fiber color coding | TIA-598-D |
| Central strength member type | GRP |
| Strength member | Waterblocking Fiberglass Yarns |
| Outer jacket ripcord | 1 |
| Bulk cable weight | 59 lbs/kft (88 kg/km) |
| Armored | No |
| Rodent protected | No |
| Self-support | No |
| Mode field diameter | 9.2 µm (1310 nm); 10.4 µm (1550 nm) |
| 1 Gigabit Ethernet performance | 5,000 m (1310 nm) |
| 10 Gigabit Ethernet performance | 10,000 m (1310 nm); 40,000 m (1550 nm) |
| Max. tensile strength during installation | 2670 N (600 lbf) |
| Max. tensile strength during operation | 800 N (180 lbf) |
| Crush resistance | 220 N/cm |
| Installation temperature range | -30°C to +60°C |
| Operating Temperature Range | -40°C to +70°C |
| Storage temperature range | -40°C to +70°C |
| ICEA compliance | S-87-640 |
| TIA/EIA compliance | ANSI/ICEA S-87-640 |
| Telcordia compliance | Telcordia GR-20 |
| Sustainability | CA Prop 65 |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.