Belden 1018A 1 Par 16 AWG apantallado Tipo KX cable

SKU:Belden 1018A
$642.00
● En stock
Descripción
Belden 1018A 004 es un cable termopar tipo KX con 1 par de 16 AWG sólido conductores (Chromel+Alumel). Cuenta con PVC aislamiento, un blindajeBeldfoil® general y un PVC cubiertaamarillo. cable marcas incluyen PLTC-ER, ITC-ER, CMG, AWM 2464 y SUN RES.
Aplicaciones
- Úsalo para cableado de señal de termopar tipo KX donde se requieren conductores Chromel+Alumel.
- Elige para instalaciones que especifican PLTC-ER, ITC-ER, CMG o AWM 2464 marcadas cable.
- Especifica para entornos donde se requiere la marca SUN RES.
cable Impresión
PLTC-ER ITC-ER CMG AWM 2464 SUN RESEspecificaciones
| Attribute | Value |
|---|---|
| Insulation Material | PVC - Polyvinyl Chloride |
| Insulation nominal thickness | 0.021 in (0.53 mm) |
| Insulation nominal diameter | 0.093 in (2.4 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 18 AWG (7x26) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket nominal thickness | 0.037 in (0.94 mm) |
| Nominal diameter | 0.264 in (6.71 mm) |
| Overall cable diameter (nominal) | 0.264 in (6.71 mm) |
| Nom. outer shield DCR | 5.93 Ohm/1000ft (19.5 Ohm/km) |
| Nom. capacitance cond-to-cond | 25 pF/ft (82 pF/m) |
| Nom. capacitance (Cond-to-Shield) | 51 pF/ft (170 pF/m) |
| Nom. inductance | 0.18 µH/ft (0.59 µH/m) |
| Nom. conductor DCR | 141 Ohm/1000ft; 63 Ohm/1000ft (210 Ohm/km) |
| Conductor DCR (nom.) | 165 Ohm/1000ft (Chromel), 66 Ohm/1000ft (Alumel) |
| Max. current | 18 Amps per Conductor @ 30°C |
| Operating | -30°C to +105°C |
| UL temperature | 105°C |
| Stationary min. bend radius | 3.1 in (79 mm) |
| Installation min. bend radius | 3.1 in (79 mm) |
| Max Pull Tension | 83 lbs (38 kg) |
| Bulk cable weight | 38 lbs/1000ft |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4 |
| Other standard compliance(s) | ISA MC 96.1-1982 Type KX |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Thermocouple Wire |
| Priced Per | FT |
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.
¿Necesita un corte a medida, precio por volumen o una ficha técnica?
Nuestro equipo cotiza largos personalizados y pedidos por volumen, normalmente el mismo día.