Belden 1059A 16 pares 20 + 1/C 22 AWG apantallado PLTC-ER Negro PVC cubierta

SKU:Belden 1059A
$976.80
● En stock
Descripción
Belden 1059A 010 es una cable de instrumentación con cubiertanegra. Está listado como 16 pares #20 + 1/C 22 AWG trenzado con aislamiento PVC y un blindaje® Beldfoil general. Las clasificaciones/marcas mostradas incluyen PLTC-ER, ITC-ER, CMG, AWM 2464 SUN RES.
Aplicaciones
- Uso en instalaciones de instrumentación cable donde se necesitan 16 pares de #20 y + 1/C 22 AWG en una sola secuencia.
- Selecciona entornos donde se especifica un blindaje general de Beldfoil®.
- Elige proyectos que requieran marcas PLTC-ER, ITC-ER, CMG o AWM 2464, incluyendo SUN RES.
Especificaciones
| Attribute | Value |
|---|---|
| Pairs | 16 |
| Pair Conductor Size | 20 AWG |
| Pair Stranding | 7x28 |
| Pair Conductor Material | BC - Bare Copper |
| Communication wire(s) | 1 |
| Communication wire size | 22 AWG |
| Communication wire stranding | 7x30 |
| Communication wire material | BC - Bare Copper |
| Conductor Type | Stranded Conductor |
| Insulation material (pairs) | PVC - Polyvinyl Chloride |
| Nom. insulation thickness (pairs) | 0.018 in (0.46 mm) |
| Pair color code | Black, White and Numbered |
| Insulation material (comm wire) | PVC - Polyvinyl Chloride |
| Nom. insulation thickness (comm wire) | 0.019 in (0.48 mm) |
| Comm Wire color | Orange |
| PVC insulation | E1 color code |
| Outer shield type | Tape |
| Outer shield material | Bi-Laminate (Alum+Poly) |
| Outer shield coverage | 100% |
| Drainwire type | 20 AWG (7x28) TC |
| Inner shield (comm wire) | No Shield |
| Nom. outer shield DCR | 6 Ohm/1000ft (20 Ohm/km) |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Nom. jacket thickness | 0.063 in (1.6 mm) |
| Overall cable diameter (nominal) | 0.684 in (17.4 mm) |
| Ripcord | Yes |
| Armor | No |
| Bulk cable weight | 238 lbs/1000ft (354 kg/km) |
| Nom. Conductor DCR (pairs) | 9.5 Ohm/1000ft (31 Ohm/km) |
| Nom. capacitance cond-to-cond (pair(s)) | 30 pF/ft (98 pF/m) |
| Nom. capacitance cond-to-shield (pairs) | 55 pF/ft (180 pF/m) |
| Nom. inductance (pair(s)) | 0.19 µH/ft (0.62 µH/m) |
| Max. Current (pair(s)) | 3 Amps per Conductor @ 25°C |
| Nom. conductor DCR (comm wire) | 14.7 Ohm/1000ft (48.2 Ohm/km) |
| UL temperature | 105°C |
| Bend radius (stationary min.) | 6.8 in (170 mm) |
| Bend radius (installation min.) | 6.8 in (170 mm) |
| Max Pull Tension | 482 lbs (219 kg) |
| Sunlight resistance | Sunlight resistance |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL1685 (FT4 Loading), FT4, T-29-520, 1202 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Listings | PLTC ITC CMG AWM 2464 SUN RES |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.