Belden 1095A 12 Triadas 18 AWG IS/OS 600V TC-ER negro PVC cubierta

SKU:Belden 1095A
$2,098.80
● En stock
Descripción
Belden 1095A 010 es una cable de instrumentación cubierta negra con 12 tríadas de 18 AWG trenzado conductores. Cuenta con aislamiento PVC con blindaje® de Beldfoil individual y en general. Marcado 600V TC-ER, 150V NPLF 90C y Dry / Wet SUN RES DIR BUR.
Aplicaciones
- Uso en instalaciones de instrumentación cable donde se necesitan múltiples tríadas para cableado de señal organizado.
- Instala en entornos secos/húmedos, incluyendo lugares que requieran SUN RES y DIR BUR marcados en el cable.
Especificaciones
| Attribute | Value |
|---|---|
| Number of elements | 12 |
| Element type | Triad(s) |
| Conductor size | 18 AWG |
| Stranding | 7x26 |
| Conductor Material | BC - Bare Copper |
| Conductor Type | Stranded Conductor |
| Nom. thickness | 0.022 in (0.56 mm) |
| Nom. insulation diameter | 0.088 in (2.2 mm) |
| Inner shield type | Tape |
| Inner shield material | Bi-Laminate (Alum+Poly) |
| Inner shield coverage | 100% |
| Inner drainwire type | 20 AWG (7x28) TC |
| Outer shield type | Tape |
| Outer shield material | Bi-Laminate (Alum+Poly) |
| Outer shield coverage | 100% |
| Outer drainwire type | 18 AWG (7x26) TC |
| Separator | Polyester Tape |
| Ripcord | Yes |
| Overall cable diameter (nominal) | 0.962 in |
| Bulk cable weight | 503 lbs/1000ft |
| Nom. conductor DCR | 6.7 Ohm/1000ft |
| Nom. inner shield DCR | 7.11 Ohm/1000ft (23.3 Ohm/km) |
| Nom. outer shield DCR | 4.8 Ohm/1000ft (16 Ohm/km) |
| Nom. capacitance cond-to-cond | 37 pF/ft (120 pF/m) |
| Nom. capacitance (Cond-to-Shield) | 43 pF/ft (140 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 30 pF/ft (98 pF/m) |
| Max. current | 6 Amps per Conductor at 30ºC |
| UL temperature | 90°C Dry, 75°C Wet |
| Operating | -20°C To +90°C Dry, +75°C Wet |
| Bend radius (stationary min.) | 3.848 in (97.74 mm) |
| Bend radius (installation min.) | 4.81 in |
| Max Pull Tension | 997 lbs (452 kg) |
| Flammability / reaction to fire | UL1685 UL Loading, FT4, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, Article 760 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |