Belden 1101A 1 Par AWG 16 apantallado EX Tipo

Descripción
Belden 1101A 010 es un cable termopar tipo EX con 1 par de sólido conductores 16AWG (Chromel+Constantan). Cuenta con aislamiento PVC , un blindajeBeldfoil® general y un PVC cubiertanegro. El cable está marcado PLTC-ER ITC-ER CMG AWM 2464 SUN RES.
Aplicaciones
- Úsase para conexiones de señal de termopar tipo EX donde se especifica una configuración de 1 par de 16AWG sólido .
- Elige para cable corridas que requieran un Beldfoil® global blindaje.
- Cumple con los requisitos de instalación que especifican PLTC-ER, ITC-ER, CMG, AWM 2464 y las marcas SUN RES.
cable Impresión
PLTC-ER ITC-ER CMG AWM 2464 SUN RESEspecificaciones
| Attribute | Value |
|---|---|
| Thermocouple type | CHROMEL/CONSTANTAN TYPE EX |
| Number of elements | 1 |
| Insulation Material | PVC - Polyvinyl Chloride |
| Insulation nominal thickness | 0.021 in (0.53 mm) |
| Insulation nominal diameter | 0.093 in (2.4 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket nominal thickness | 0.037 in (0.94 mm) |
| Armor | No |
| Nominal diameter | 0.264 in (6.71 mm) |
| Overall cable diameter (nominal) | 0.264 in (6.71 mm) |
| Stationary min. bend radius | 2.6 in (66 mm) |
| Installation min. bend radius | 2.6 in (66 mm) |
| Max Pull Tension | 83 lbs (38 kg) |
| Bulk cable weight | 38 lbs/1000ft |
| Nom. capacitance cond-to-cond | 25 pF/ft (82 pF/m) |
| Nom. capacitance (Cond-to-Shield) | 51 pF/ft (170 pF/m) |
| Nom. inductance | 0.18 µH/ft (0.59 µH/m) |
| Conductor DCR (nom.) | 165 Ohm/1000ft (Chromel), 121 Ohm/1000ft (Constantan) |
| Nom. outer shield DCR | 38 Ohm/1000ft (120 Ohm/km) |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance |
| Flammability / reaction to fire | UL1685 (FT4 Loading), FT4, T-29-520, 1202 |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | ISA MC 96.1-1982 Type EX |
| Item Type | Belden Thermocouple Wire |
| Priced Per | FT |
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.
¿Necesita un corte a medida, precio por volumen o una ficha técnica?
Nuestro equipo cotiza largos personalizados y pedidos por volumen, normalmente el mismo día.