Belden 29504 010, Cable VFD, 3-8 AWG TC + 1G TC, XLPE, Blindado, Cubierta de PVC Negro

SKU:Belden 29504 010
$2,262.00
● En stock
Descripción
Belden 29504 010, Cable VFD, 3-8 AWG TC + 1G TC, Aislamiento XLPE, Blindado, Cubierta de PVC Negro
Cable VFD flexible Belden 300% tierra / cable de suministro de motor flexible UL de 1000 V
Cobre estañado trenzado de 3-8 AWG (7x19x29) + conductores de tierra TC de 1-8 AWG
Aislamiento XLPE, código de color M4 + tierra aislada de PVC
Estampado Beldfoil® + 85% TC braid shield + TC drainwire
cubierta de PVC resistente al sol y al aceite
600/1000 V TC-ER, 90ºC Húmedo/Seco
Especificaciones
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 8 AWG |
| Conductor stranding | 7x19x29 |
| Conductor Material | TC - Tinned Copper |
| Earth/ground wires | Yes |
| Insulated ground | 1 x 8 AWG, 7x19x29, TC - Tinned Copper, Insulated Ground Wire |
| Uninsulated ground wire | 4 x 14 AWG, 41x40, TC - Tinned Copper, Segmented Ground Wire (4 Totaling 8 AWG) |
| Conductor insulation material | XLP, XLPO, XLPE (Thermoset) |
| Conductor insulation nominal thickness | 0.062 in (1.6 mm) |
| Conductor nominal insulation diameter | 0.278 in (7.06 mm) |
| Conductor color code | ICEA Chart M4 |
| Insulated ground insulation material | PVC - Polyvinyl Chloride |
| Insulated ground nominal thickness | 0.062 in (1.6 mm) |
| Insulated ground nominal insulation diameter | 0.278 in (7.06 mm) |
| Insulated ground color | Green/Yellow Stripe |
| Shielded | Shielded |
| Outer shield (tape) | Tri-Laminate (Alum+Poly+Alum), 100% coverage |
| Drainwire type | 14 AWG (41x30) TC |
| Outer shield (braid) | Tinned Copper (TC), 85% coverage |
| Nom. outer shield DCR | 0.6 Ohm/1000ft (2.0 Ohm/km) |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Jacket nominal thickness | 0.095 in (2.4 mm) |
| Overall cable diameter (nominal) | 0.901 in (22.9 mm) |
| Ripcord | Yes |
| Voltage range | 1KV |
| Nom. Conductor DCR (Conductor(s)) | 0.599 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 26 pF/ft (85 pF/m) |
| Nom. capacitance (Cond-to-Shield) | 47 pF/ft (150 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 47 pF/ft (150 pF/m) |
| Nom. characteristic impedence | 71 Ohm |
| Nom. inductance cond-grnd | 0.17 µH/ft |
| Nom. velocity of prop. | 55% |
| Max. current | 55 Amps per Conductor at 30ºC (per NEC) |
| Nom. conductor DCR (insulated ground) | 0.6795 Ohm/1000ft (2.229 Ohm/km) |
| Nom. conductor DCR (segmented ground wire) | 0.67 Ohm/1000ft (2.2 Ohm/km) |
| UL temperature | 90°C Dry, 90°C Wet |
| Operating temperature | -40°C To +90°C |
| Bend radius (stationary min.) | 10.8 in (274 mm) |
| Bend radius (installation min.) | 10.8 in (274 mm) |
| Max Pull Tension | 1011 lbs (458.6 kg) |
| Bulk cable weight | 564 lbs/1000ft |
| NEC / UL compliance | Article 336, TC-ER, WTTC, UL Flexible Motor Supply Cable |
| AWM compliance | AWM I/II A/B |
| CEC / C(UL) compliance | CIC, TC |
| ICEA compliance | S-95-658 |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, IEEE 1202 FT4 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
| Other Part Numbers | 29504 010, 29504 010100, 29504 010250, 29504 010500, 29504 0101000 |
| Priced Per | FT |