Belden 29523C 010, Cable VFD, 3C-10 AWG Cobre Desnudo + 3G-14 AWG Cobre Desnudo, XLPE, Blindado, Forro Negro

SKU:Belden 29523C 010
$600.00
● En stock
Descripción
Belden 29523C 010, Cable VFD, 3C-10 AWG Cobre Desnudo + 3G-14 AWG Cobre Desnudo, XLPE, Blindado, Forro Negro
Belden Básicos 600V VFD
3-10 AWG trenzado (7x18) conductores de cobre desnudo + alambres de tierra segmentados de cobre desnudo simétricos AWG 3-14
Aislamiento XLPE en conductores, código de color M4
Blindaje general de cintas de cobre duales aplicado helicoidalmente
Forro PVC General, ripcord
600/1000 V TC-ER, 90ºC Mojado/Seco
Especificaciones
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 10 AWG |
| Conductor stranding | 7x18 |
| Conductor Material | BC - Bare Copper |
| Segmented ground wire | 3 |
| Ground size | 14 AWG |
| Ground stranding | 7x22 |
| Ground material | BC - Bare Copper |
| Insulation Material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Nom. thickness | 0.030 in (0.76 mm) |
| Nom. insulation diameter | 0.172 in (4.37 mm) |
| Color Code | ICEA Chart M4 |
| Shield Coverage | 100% |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Nom. jacket thickness | 0.060 in (1.5 mm) |
| Overall cable diameter (nominal) | 0.506 in (12.9 mm) |
| Armor | No |
| Composite | No |
| Nom. conductor DCR | 0.895 Ohm/1000ft (2.94 Ohm/km) |
| Nom. capacitance cond-to-cond | 31 pF/ft (100 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 60 pF/ft (200 pF/m) |
| Nom. characteristic impedence | 44 Ohm |
| Nom. velocity of prop. | 55% |
| Max. current | 40 Amps per Conductor at 30ºC |
| Nom. outer shield DCR | 0.82 Ohm/1000ft (2.7 Ohm/km) |
| Operating | -40°C To +90°C |
| Stationary min. bend radius | 6.1 in (150 mm) |
| Installation min. bend radius | 6.1 in (150 mm) |
| Max Pull Tension | 400 lbs (180 kg) |
| Bulk cable weight | 238 lbs/1000ft (354 kg/km) |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, TC-ER, XHHW-2 |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
| Other Part Numbers | 29523C 010, 29523C 010100, 29523C 010250, 29523C 010500, 29523C 0101000 |
| Priced Per | FT |
Documentos
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.
¿Necesita un corte a medida, precio por volumen o una ficha técnica?
Nuestro equipo cotiza largos personalizados y pedidos por volumen, normalmente el mismo día.