Belden 5200UE 009U, Multi Conductor Audio Cable 2C 16 AWG FRPVC White

SKU:Belden 5200UE 009U
● En stock
Descripción
Belden 5200UE 009U is a security and commercial audio cable designed for indoor riser (CMR) installations requiring 2-conductor performance. It features 2-16 AWG stranded bare copper conductors with polypropylene insulation and a PVC jacket with a ripcord for easier stripping. The cable is UL 1666 Riser and FT4 rated, with a 300 V (CMR) UL voltage rating and a 75°C UL temperature rating.
Key Features
- 2-16 AWG stranded bare copper conductors for signal and control use.
- Polypropylene insulation with a PVC jacket.
- Includes a ripcord for easier stripping.
- UL 1666 Riser and FT4 flammability / reaction to fire ratings.
- 300 V (CMR) UL voltage rating and 75°C UL temperature rating.
Technical Specs
Construction & Materials
| Number of conductors | 2 |
|---|---|
| Conductor size | 16 AWG |
| Conductor stranding | 19x29 |
| Conductor material | BC - Bare Copper |
| Insulation material | PO - Polyolefin |
| Insulation nominal thickness | 0.008 in (0.20 mm) |
| Insulation nominal diameter | 0.073 in (1.9 mm) |
| Conductor color code | Black, Red |
| Jacket material | PVC - Polyvinyl Chloride |
| Jacket nominal thickness | 0.017 in (0.43 mm) |
Electrical Characteristics
| Nominal conductor DCR | 4.2 Ohm/1000ft |
|---|---|
| Nominal capacitance (cond-to-cond) | 23 pF/ft (75 pF/m) |
| Nominal inductance | 0.14 μH/ft (0.46 μH/m) |
| Max. current | 6.25 Amps per Conductor @ 25°C |
Physical, Mechanical & Environmental
| Overall cable diameter (nominal) | 0.180 in (4.57 mm) |
|---|---|
| Operating temperature | -20°C to +75°C |
| Minimum bend radius (stationary) | 1.8 in (46 mm) |
| Minimum bend radius (installation) | 1.8 in (46 mm) |
| Max. pull tension | 59 lbs (27 kg) |
| Bulk cable weight | 24 lbs/1000ft |
| Environmental suitability | Indoor - Riser, Indoor |
Compliance & Certifications
| NEC / UL compliance | Article 800, CMR |
|---|---|
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1666 Riser, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Additional Reference
| Plenum number | 6200UE |
|---|
Applications
- Supports data circuits where consistent signal and control performance is required.
- Commonly used in monitor/detection circuits for system status and event monitoring.
- Fits control circuits that need dependable 2-conductor connectivity.
- Suitable for initiating circuits in security and commercial audio system designs.
- Works in notification circuits where signal transmission is needed for alerts and indications.
Belden™ and all associated trademarks are the property of their respective owners.
Especificaciones
| Attribute | Value |
|---|---|
| Number of Conductors | 2 |
| Conductor size | 16 AWG |
| Conductor stranding | 19x29 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PO - Polyolefin |
| Insulation nominal thickness | 0.008 in (0.20 mm) |
| Insulation nominal diameter | 0.073 in (1.9 mm) |
| Conductor color code | Black, Red |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket nominal thickness | 0.017 in (0.43 mm) |
| Nominal conductor DCR | 4.2 Ohm/1000ft |
| Nominal capacitance (Cond-to-Cond) | 23 pF/ft (75 pF/m) |
| Nominal inductance | 0.14 µH/ft (0.46 µH/m) |
| Max. current | 6.25 Amps per Conductor @ 25°C |
| Overall cable diameter (nominal) | 0.180 in (4.57 mm) |
| Operating temperature | -20°C to +75°C |
| Minimum bend radius (stationary) | 1.8 in (46 mm) |
| Minimum bend radius (installation) | 1.8 in (46 mm) |
| Max Pull Tension | 59 lbs (27 kg) |
| Bulk cable weight | 24 lbs/1000ft |
| Environmental suitability | Indoor - Riser, Indoor |
| NEC / UL compliance | Article 800, CMR |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1666 Riser, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Plenum number | 6200UE |
| Priced Per | FT |
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.
¿Necesita un corte a medida, precio por volumen o una ficha técnica?
Nuestro equipo cotiza largos personalizados y pedidos por volumen, normalmente el mismo día.