Belden 5340F1 010, Multi Conductor 1 FS PR 18 AWG PVC PVC Black

SKU:Belden 5340F1 010
● En stock
Descripción
Belden 5340F1 010 is a security & sound cable with 1 pair of 18 AWG stranded tinned copper conductors, PVC insulation, and a PVC jacket. It features a tape shield with 100% coverage plus a 20 AWG (7x28) TC drainwire and Waterblock Tape for added protection in noisy and wet locations and below-grade duct runs. Rated-CMG-FPL-PLTC- and UL Voltage Rating: 300 V, it is specified for indoor/outdoor use with sunlight resistance.
Key Features
- 1 pair construction with 18 AWG stranded tinned copper conductors (7x26).
- PVC insulation with black & red color code.
- Tape shield (Bi-Laminate (Alum+Poly)) with 100% coverage and a 20 AWG (7x28) TC drainwire.
- Waterblocking: Waterblock Tape.
- PVC jacket with environmental suitability: indoor/outdoor, indoor, outdoor, sunlight resistance.
- Ratings: Rated-CMG-FPL-PLTC-.
Technical Specs
Construction & Materials
| Number of elements | 1 pair |
|---|---|
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor material | TC - Tinned Copper |
| Insulation material | PVC - Polyvinyl Chloride |
| Nom. thickness | 0.017 in (0.43 mm) |
| Nom. insulation diameter | 0.080 in (2.0 mm) |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield coverage | 100% |
| Drainwire type | 20 AWG (7x28) TC |
| Jacket material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.037 in (0.94 mm) |
| Nom. diameter | 0.262 in (6.65 mm) |
| Overall cable diameter (nominal) | 0.262 in (6.65 mm) |
Electrical Characteristics
| Nom. conductor DCR | 7 Ohm/1000ft (23 Ohm/km) |
|---|---|
| Nom. capacitance cond-to-cond | 45 pF/ft (150 pF/m) |
| Max. current | 14 Amps per Conductor @ 25°C |
| Nom outer shield DCR | 8.5 Ohm/1000ft (28 Ohm/km) |
| UL voltage rating | 300 V |
Environmental & Mechanical Ratings
| UL temperature | 90°C |
|---|---|
| Operating temperature | -20°C to +90°C |
| Bend radius (stationary min.) | 2.6 in (66 mm) |
| Bend radius (installation min.) | 2.6 in (66 mm) |
| Max. pull tension | 57 lbs (26 kg) |
| Bulk cable weight | 27 lbs/1000ft (40 kg/km) |
Compliance & Certifications
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4, IEC 60332-1-2 |
|---|---|
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 725, Article 760, Article 800 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Designed for security system wiring where shielded, waterblocked construction is specified.
- Well-suited for intercom/PA installations that require a listed security & sound cable.
- Commonly used in audio/speaker runs where a 1 pair shielded cable is called for.
- Applied in power-limited controls circuits covered under the listed NEC / UL articles.
- Specified for noisy & wet location installations where shielding and waterblocking are required.
- Appropriate for below-grade duct runs as indicated in the application list.
Belden™ and all associated trademarks are the property of their respective owners.
Especificaciones
| Attribute | Value |
|---|---|
| Number of elements | 1 pair |
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. thickness | 0.017 in (0.43 mm) |
| Nom. insulation diameter | 0.080 in (2.0 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 20 AWG (7x28) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.037 in (0.94 mm) |
| Nom. diameter | 0.262 in (6.65 mm) |
| Overall cable diameter (nominal) | 0.262 in (6.65 mm) |
| Nom. conductor DCR | 7 Ohm/1000ft (23 Ohm/km) |
| Nom. capacitance cond-to-cond | 45 pF/ft (150 pF/m) |
| Max. current | 14 Amps per Conductor @ 25°C |
| Nom. outer shield DCR | 8.5 Ohm/1000ft (28 Ohm/km) |
| UL Voltage Rating | 300 V |
| UL temperature | 90°C |
| Operating temperature | -20°C to +90°C |
| Bend radius (stationary min.) | 2.6 in (66 mm) |
| Bend radius (installation min.) | 2.6 in (66 mm) |
| Max Pull Tension | 57 lbs (26 kg) |
| Bulk cable weight | 27 lbs/1000ft (40 kg/km) |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 725, Article 760, Article 800 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.
¿Necesita un corte a medida, precio por volumen o una ficha técnica?
Nuestro equipo cotiza largos personalizados y pedidos por volumen, normalmente el mismo día.