Belden 6201FE 877, Multi Conductor 3C 16 AWG FLRST FS Natural

SKU:Belden 6201FE 877
● En stock
Descripción
Belden 6201FE 877 is a security & commercial audio cable with 3 conductor 16 AWG stranded (19x29) BC - bare copper conductors and an overall Beldfoil® tape shield (foil side out) with drain wire. It uses Flamarrest® insulation and a Flamarrest® jacket with ripcord, and carries a Plenum-CMP rating with a UL voltage rating of 300 V (CMP). Electrical performance includes max. current of 6.25 Amps per Conductor @ 25°C. It also features sequential footage marking every two feet to support measuring and cut-to-length work.
Key Features
- 3 conductor 16 AWG stranded (19x29) BC - bare copper conductors for security and commercial audio wiring.
- Overall Beldfoil® tape shield (foil side out) with drain wire and 100% shield coverage.
- Flamarrest® insulation and a Flamarrest® jacket with ripcord.
- Plenum-CMP rated with UL voltage rating: 300 V (CMP).
- Sequential footage marking every two feet to support accurate pulls and cut-to-length work.
Technical Specs
Construction & Materials
| Conductor stranding | 19x29 |
|---|---|
| Insulation material | PVC - Polyvinyl Chloride |
| Insulation nominal thickness | 0.009 in (0.23 mm) |
| Insulation color code | Black, Red, White |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield coverage | 100% |
| Drainwire type | 24 AWG (7x32) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Outer jacket nominal thickness | 0.015 in (0.38 mm) |
Physical Specs
| Overall cable diameter (nominal) | 0.195 in (4.95 mm) |
|---|---|
| Bulk cable weight | 36 lbs/1000ft (54 kg/km) |
| Non-Plenum number | 5201FE |
Performance & Electrical Characteristics
| Conductor DCR (nom.) | 4 Ohm/1000ft (13 Ohm/km) |
|---|---|
| Capacitance, Cond-to-Cond (nom.) | 81.5 pF/ft (267 pF/m) |
| Capacitance, Cond-to-other (nom.) | 146.7 pF/ft (481.3 pF/m) |
| Inductance (nom.) | 0.15 μH/ft (0.49 μH/m) |
| Max. current | 6.25 Amps per Conductor @ 25°C |
| Outer Shield DCR (nom.) | 15.2 Ohm/1000ft (49.9 Ohm/km) |
Environmental & Mechanical Ratings
| UL temperature | 75°C |
|---|---|
| Operating temperature | 0°C to +75°C |
| Bend radius (stationary min.) | 2.0 in (51 mm) |
| Bend radius (installation min.) | 2.0 in (51 mm) |
| Max. pull tension | 116 lbs (52.6 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
Compliance & Certifications
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6 |
|---|---|
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Sustainability | CA Prop 65 |
Applications
- Designed for security systems using shielded multi-conductor cable for signal and control wiring.
- Supports intercom/PA systems in indoor installations.
- Commonly used in sound/audio systems where consistent electrical characteristics are needed.
- Suitable for power limited controls in plenum and other indoor environments.
Belden™ and all associated trademarks are the property of their respective owners.
Especificaciones
| Attribute | Value |
|---|---|
| Conductor stranding | 19x29 |
| Insulation Material | PVC - Polyvinyl Chloride |
| Insulation nominal thickness | 0.009 in (0.23 mm) |
| Insulation color code | Black, Red, White |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 24 AWG (7x32) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Outer jacket nominal thickness | 0.015 in (0.38 mm) |
| Overall cable diameter (nominal) | 0.195 in (4.95 mm) |
| Bulk cable weight | 36 lbs/1000ft (54 kg/km) |
| Non-Plenum number | 5201FE |
| Conductor DCR (nom.) | 4 Ohm/1000ft (13 Ohm/km) |
| Capacitance, Cond-to-Cond (nom.) | 81.5 pF/ft (267 pF/m) |
| Capacitance, Cond-to-other (nom.) | 146.7 pF/ft (481.3 pF/m) |
| Inductance (nom.) | 0.15 µH/ft (0.49 µH/m) |
| Max. current | 6.25 Amps per Conductor @ 25°C |
| Outer shield DCR (nom) | 15.2 Ohm/1000ft (49.9 Ohm/km) |
| UL temperature | 75°C |
| Operating temperature | 0°C to +75°C |
| Bend radius (stationary min.) | 2.0 in (51 mm) |
| Bend radius (installation min.) | 2.0 in (51 mm) |
| Max Pull Tension | 116 lbs (52.6 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6 |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Sustainability | CA Prop 65 |
| Priced Per | FT |
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.
¿Necesita un corte a medida, precio por volumen o una ficha técnica?
Nuestro equipo cotiza largos personalizados y pedidos por volumen, normalmente el mismo día.