Belden 6304FE 877U, Multi Conductor 6C 18 AWG flrst fs Natural

Descripción
Belden 6304FE 877U is a plenum-rated Security & Sound Cable for indoor installations. It features 6 stranded 18 AWG BC - Bare Copper conductors with PVC - Polyvinyl Chloride insulation and a PVC - Polyvinyl Chloride jacket with Ripcord: Yes. Electrical characteristics include UL Voltage Rating: 300 V, Nom. Conductor DCR: 6.5 Ohm/1000ft, and Nom. capacitance Cond-to-Cond: 42 pF/ft (140 pF/m). It is suitable for Indoor - Plenum, Indoor environments and meets NFPA 262 and UL 910 (Plenum).
Key Features
- 6 stranded 18 AWG conductors with Stranding: 7x26 and Conductor Material: BC - Bare Copper.
- Tape shield with Shield Material: Bi-Laminate (Alum+Poly), Coverage: 100%, and Drainwire type: 24 AWG (7x32) TC.
- PVC - Polyvinyl Chloride jacket with Ripcord: Yes to support easier handling during installation.
- Plenum suitability with Flammability / reaction to fire: NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2.
- Sequential footage Marking every two feet to simplify measuring and pull tracking.
Technical Specs
Construction & Materials
| Number of Conductors | 6 |
|---|---|
| Conductor Size | 18 AWG |
| Stranding | 7x26 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. Thickness | 0.009 in (0.23 mm) |
| Nom. Insulation Diameter | 0.063 in (1.6 mm) |
| Color Code | Black, Red, White, Green, Brown, Blue |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drainwire Type | 24 AWG (7x32) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Nom. Jacket Thickness | 0.015 in (0.38 mm) |
| Non-Plenum Number | 5304FE |
Electrical Characteristics
| Nom. Outer Shield DCR | 14.4 Ohm/1000ft (47.2 Ohm/km) |
|---|---|
| Nom. Capacitance Cond-to-other (conds + Shield) | 76 pF/ft (250 pF/m) |
| Max. Current | 9.8 Amps per Conductor @ 25°C |
Physical Dimensions & Weight
| Nom. Diameter | 0.226 in (5.74 mm) |
|---|---|
| Overall Cable Diameter (nominal) | 0.226 in (5.74 mm) |
| Bulk Cable Weight | 48 lbs/1000ft |
Environmental & Mechanical Ratings
| UL Temperature | 75°C |
|---|---|
| Operating | 0°C to +75°C |
| Stationary Min. Bend Radius | 2.3 in (58 mm) |
| Installation Min. Bend Radius | 2.3 in (58 mm) |
| Max. Pull Tension | 140 lbs (64 kg) |
| Environmental Suitability | Indoor - Plenum, Indoor |
Compliance & Certifications
| CPR Compliance | CPR Euroclass: Eca |
|---|---|
| NEC / UL Compliance | Article 800, CMP |
| CEC / C(UL) Compliance | CMP |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK Regulation Compliance | UKCA Mark |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Use in security system wiring where a plenum-rated cable is required for indoor routing.
- Support intercom/PA installations that need multi-conductor cabling for signal distribution.
- Connect audio/speaker runs in building spaces where plenum compliance is specified.
- Fit power-limited controls for indoor control circuits that call for a shielded construction.
- Handle noisy environment installations where shielding helps manage interference in the cable run.
Belden™ and all associated trademarks are the property of their respective owners.
Especificaciones
| Attribute | Value |
|---|---|
| Number of Conductors | 6 |
| Conductor size | 18 AWG |
| Stranding | 7x26 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. thickness | 0.009 in (0.23 mm) |
| Nom. insulation diameter | 0.063 in (1.6 mm) |
| Color Code | Black, Red, White, Green, Brown, Blue |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drainwire type | 24 AWG (7x32) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.015 in (0.38 mm) |
| Non-Plenum number | 5304FE |
| Nom. outer shield DCR | 14.4 Ohm/1000ft (47.2 Ohm/km) |
| Nom. capacitance cond-to-other (conds + Shield) | 76 pF/ft (250 pF/m) |
| Max. current | 9.8 Amps per Conductor @ 25°C |
| Nom. diameter | 0.226 in (5.74 mm) |
| Overall cable diameter (nominal) | 0.226 in (5.74 mm) |
| Bulk cable weight | 48 lbs/1000ft |
| UL temperature | 75°C |
| Operating | 0°C to +75°C |
| Stationary min. bend radius | 2.3 in (58 mm) |
| Installation min. bend radius | 2.3 in (58 mm) |
| Max Pull Tension | 140 lbs (64 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.
¿Necesita un corte a medida, precio por volumen o una ficha técnica?
Nuestro equipo cotiza largos personalizados y pedidos por volumen, normalmente el mismo día.