Belden 6341UE 877, Multi Conductor Cable 2 Pair 18 AWG FLRST

SKU:Belden 6341UE 877
● En stock
Descripción
Belden 6341UE 877 is a Security & Sound Cable for Plenum-CMP installations, built with 2 pair(s) of 18 AWG stranded BC - Bare Copper conductors and a PVC - Polyvinyl Chloride jacket. It features PVC - Polyvinyl Chloride insulation with color code Black & Red, Black & White, and includes a ripcord for easier jacket removal. Electrical ratings include a UL Voltage Rating of 300 V and a UL temperature of 75°C, with an operating temperature of 0°C To +75°C. Installation handling specs include a 2.53 in (64.3 mm) minimum bend radius and a max. pull tension of 90 lbs (41 kg).
Key Features
- Plenum-CMP rated Security & Sound Cable for plenum installations.
- 2 pair(s) of 18 AWG stranded BC - Bare Copper conductors (Stranding: 7x26).
- PVC - Polyvinyl Chloride insulation with color code Black & Red, Black & White.
- PVC - Polyvinyl Chloride outer jacket with ripcord: Yes.
- UL Voltage Rating: 300 V; UL temperature: 75°C; Operating temperature: 0°C To +75°C.
- Stationary min. bend radius: 2.53 in (64.3 mm); Installation min. bend radius: 2.53 in (64.3 mm).
- Max. pull tension: 90 lbs (41 kg).
Technical Specs
Electrical & Physical Specs
| Nom. insulation thickness | 0.009 in (0.23 mm) |
|---|---|
| Nom. insulation diameter | 0.063 in (1.6 mm) |
| Nom. jacket thickness | 0.015 in (0.38 mm) |
| Nom. overall diameter | 0.253 in (6.43 mm) |
| Bulk cable weight | 32 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. conductor DCR | 6.93 Ohm/1000ft |
|---|---|
| Nom. capacitance (Cond-to-Cond) | 32.5 pF/ft (107 pF/m) |
| Max. current | 4 Amps per Conductor at 20ºC |
Environmental & Mechanical Ratings
| Flammability / reaction to fire | NFPA 262 (UL910), FT6 |
|---|
Compliance & Certifications
| NEC / UL compliance | Article 800, CMP |
|---|---|
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Construction & Marking
| Non-Plenum number | 5341UE |
|---|---|
| Construction | 18 AWG Bare Copper Conductors, Flamarrest Insulation, twisted into pairs, multiple pairs cabled together, Flamarrest Jacket with ripcord |
| Footage marking | Sequential footage marking every two feet |
Applications
- Designed for Security System wiring where plenum-rated cable is required.
- Use it for Intercom/PA installations in building spaces that call for CMP cable.
- Choose it for Audio/Speaker runs where a paired security & sound cable is used.
- Apply it in Power-Limited Controls circuits for signal and control wiring needs.
Belden™ and all associated trademarks are the property of their respective owners.
Especificaciones
| Attribute | Value |
|---|---|
| Nom. insulation thickness | 0.009 in (0.23 mm) |
| Nom. insulation diameter | 0.063 in (1.6 mm) |
| Nom. jacket thickness | 0.015 in (0.38 mm) |
| Nom. overall diameter | 0.253 in (6.43 mm) |
| Bulk cable weight | 32 lbs/1000ft |
| Nom. conductor DCR | 6.93 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 32.5 pF/ft (107 pF/m) |
| Max. current | 4 Amps per Conductor at 20ºC |
| Flammability / reaction to fire | NFPA 262 (UL910), FT6 |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum number | 5341UE |
| Construction | 18 AWG Bare Copper Conductors, Flamarrest Insulation, twisted into pairs, multiple pairs cabled together, Flamarrest Jacket with ripcord |
| Footage marking | Sequential footage marking every two feet |
| Priced Per | FT |
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.