Belden 6441FE 877, Multi Conductor 2 Pair 20 AWG FLRST FS Natural

Descripción
Belden 6441FE 877 is a plenum-rated (CMP) security and sound cable built for reliable signal and control wiring in indoor spaces. It features 2 twisted pairs of 20 AWG stranded bare copper conductors with PVC - Polyvinyl Chloride insulation, along with an overall tape shield and drain wire to help reduce interference in noisy environments. The PVC - Polyvinyl Chloride outer jacket includes a ripcord for easier pulls and stripping, and the cable is rated 300 V with a max current of 3 Amps per Conductor at 25ºC.
Key Features
- Plenum-rated (CMP) construction for indoor installations.
- 2 twisted pairs of 20 AWG stranded bare copper conductors (7x28) for signal and control wiring.
- PVC - Polyvinyl Chloride insulation with color code: Black & Red, Black & White.
- Overall tape shield with 100% coverage and Bi-Laminate (Alum+Poly) material, plus drainwire type: 22 AWG (7x30) TC.
- PVC - Polyvinyl Chloride jacket with ripcord: Yes.
- UL voltage rating: 300 V; max. current: 3 Amps per Conductor at 25ºC.
- Sequential footage marking every two feet.
Technical Specs
Construction & Materials
| Pairs | 2 |
|---|---|
| Conductor Size | 20 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.009 in (0.23 mm) |
| Nom. insulation diameter | 0.054 in (1.4 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Jacket thickness (nom.) | 0.015 in (0.38 mm) |
| Nom. Diameter | 0.228 in |
Performance & Electrical Characteristics
| Nom Outer Shield DCR | 10.39 Ohm/1000ft (34.09 Ohm/km) |
|---|---|
| Nom. Conductor DCR | 10.9 Ohm/1000ft |
| Nom. capacitance Cond-to-Cond | 36 pF/ft (120 pF/m) |
| Nom. capacitance Cond-to-other (Conds + Shield) | 64.8 pF/ft (213 pF/m) |
| Nom. inductance | 0.16 μH/ft (0.52 μH/m) |
Environmental & Mechanical Ratings
| UL temperature | 75°C |
|---|---|
| Operating temperature | 0°C To +75°C |
| Bend Radius (stationary min.) | 2.28 in (57.9 mm) |
| Bend Radius (installation min.) | 2.28 in |
| Max. pull tension | 59.5 lbs (27.0 kg) |
| Bulk Cable Weight | 29 lbs/1000ft |
| Environmental suitability | Indoor |
Compliance & Certifications
| Flammability / reaction to fire | NFPA 262 (UL910), FT6 |
|---|---|
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Cross-Reference
| Non-Plenum number | 5441FE |
|---|
Applications
- Use in security system installations where dependable signal and control wiring is required.
- Support intercom/PA systems for indoor audio and communication runs.
- Run audio/speaker wiring where shielded construction can help manage interference.
- Install for power-limited controls in indoor environments.
- Deploy in noisy environment runs where the overall tape shield and drain wire help reduce interference.
Belden™ and all associated trademarks are the property of their respective owners.
Especificaciones
| Attribute | Value |
|---|---|
| Pairs | 2 |
| Conductor size | 20 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.009 in (0.23 mm) |
| Nom. insulation diameter | 0.054 in (1.4 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Jacket thickness (nom.) | 0.015 in (0.38 mm) |
| Nom. diameter | 0.228 in |
| Nom. outer shield DCR | 10.39 Ohm/1000ft (34.09 Ohm/km) |
| Nom. conductor DCR | 10.9 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 36 pF/ft (120 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 64.8 pF/ft (213 pF/m) |
| Nom. inductance | 0.16 µH/ft (0.52 µH/m) |
| UL temperature | 75°C |
| Operating temperature | 0°C To +75°C |
| Bend radius (stationary min.) | 2.28 in (57.9 mm) |
| Bend radius (installation min.) | 2.28 in |
| Max Pull Tension | 59.5 lbs (27.0 kg) |
| Bulk cable weight | 29 lbs/1000ft |
| Environmental suitability | Indoor |
| Flammability / reaction to fire | NFPA 262 (UL910), FT6 |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum number | 5441FE |
| Priced Per | FT |
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.
¿Necesita un corte a medida, precio por volumen o una ficha técnica?
Nuestro equipo cotiza largos personalizados y pedidos por volumen, normalmente el mismo día.