Belden 6508FE 877U, 22 AWG 10C Shielded Flamarrest Jacket 1,000’ Box

SKU:Belden 6508FE 877U
● En stock
Descripción
Belden 6508FE 877U is a plenum-rated security & sound cable with 10-22 AWG stranded bare copper conductors and an overall Beldfoil® tape shield. It features Flamarrest® insulation and a Flamarrest® PVC jacket with ripcord, and includes a drain wire for shield termination. With UL voltage rating: 300 V (CMP) and UL temperature: 75°C, it is designed for Indoor - Plenum, Indoor installations.
Key Features
- Security & sound cable construction with 10 conductors and 22 AWG conductor size.
- Overall tape shield with 100% coverage using Bi-Laminate (Alum+Poly) shield material.
- Drainwire type: 24 AWG (7x32) TC for shield continuity and termination.
- Flamarrest® insulation and Flamarrest® PVC jacket with ripcord for easier stripping during installation.
- Sequential footage marking every two feet to support cut-to-length accuracy.
- Environmental suitability: Indoor - Plenum, Indoor.
Technical Specs
Construction & Materials
| Number of conductors | 10 |
|---|---|
| Conductor size | 22 AWG |
| Conductor stranding | 7x30 |
| Conductor material | BC - Bare Copper |
| Insulation material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.009 in (0.23 mm) |
| Nom. insulation diameter | 0.047 in (1.2 mm) |
| Color code | Black, Red, White, Green, Brown, Blue, Orange, Yellow, Purple, Gray |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield coverage | 100% |
| Jacket material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.015 in (0.38 mm) |
Dimensions & Weight
| Nom. diameter | 0.222 in (5.64 mm) |
|---|---|
| Overall cable diameter (nominal) | 0.222 in (5.64 mm) |
| Bulk cable weight | 38 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. conductor DCR | 16.2 Ohm/1000ft |
|---|---|
| Nom. capacitance cond-to-cond | 33 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 59 pF/ft (190 pF/m) |
| Max. current | 1.9 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 18.54 Ohm/1000ft (60.83 Ohm/km) |
Environmental & Mechanical Ratings
| Operating temperature | 0°C to +75°C |
|---|---|
| Bend radius (stationary min.) | 2.22 in (56.4 mm) |
| Bend radius (installation min.) | 2.22 in (56.4 mm) |
| Max. pull tension | 97 lbs (44 kg) |
Compliance & Certifications
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6 |
|---|---|
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Related Part Reference
| Non-plenum number | 5508FE |
|---|
Applications
- Use it for security system wiring in Indoor - Plenum, Indoor spaces.
- Run intercom/PA connections where shielded construction can be beneficial in a noisy environment.
- Choose it for audio/speaker runs that require a plenum-rated cable option.
- Install it for power-limited controls installations in plenum areas.
Belden™ and all associated trademarks are the property of their respective owners.
Especificaciones
| Attribute | Value |
|---|---|
| Number of Conductors | 10 |
| Conductor size | 22 AWG |
| Conductor stranding | 7x30 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.009 in (0.23 mm) |
| Nom. insulation diameter | 0.047 in (1.2 mm) |
| Color Code | Black, Red, White, Green, Brown, Blue, Orange, Yellow, Purple, Gray |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Jacket Material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.015 in (0.38 mm) |
| Nom. diameter | 0.222 in (5.64 mm) |
| Overall cable diameter (nominal) | 0.222 in (5.64 mm) |
| Bulk cable weight | 38 lbs/1000ft |
| Nom. conductor DCR | 16.2 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 33 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 59 pF/ft (190 pF/m) |
| Max. current | 1.9 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 18.54 Ohm/1000ft (60.83 Ohm/km) |
| Operating temperature | 0°C to +75°C |
| Bend radius (stationary min.) | 2.22 in (56.4 mm) |
| Bend radius (installation min.) | 2.22 in (56.4 mm) |
| Max Pull Tension | 97 lbs (44 kg) |
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6 |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum number | 5508FE |
| Priced Per | FT |