Contacto1-800-975-3686
Ramcorp Wire & Cable

Belden 7896A T5U DeviceBus para ODVA 2 16 AWG PVC

Belden 7896A T5U

SKU:Belden 7896A T5U

$1,186.80

En stock

Descripción

Especificaciones

Belden 7896A T5U DeviceBus para ODVA 2 16 AWG PVC specifications
AttributeValue
Conductor configuration2 Pair 16+18AWG (19x29+19x30)
Power pair1, 16 AWG, 19x29, TC - Tinned Copper
Data pair1, 18 AWG, 19x30, TC - Tinned Copper
Power insulationPVC/Nylon - Polyvinyl Chloride + Nylon, 0.022 in (0.56 mm) nominal thickness, 0.101 in (2.57 mm) nominal insulation diameter, Red & Black
Data insulationPP - Polypropylene, 0.033 in (0.84 mm) nominal thickness, 0.182 in (4.62 mm) nominal insulation diameter, Blue & White, Flame Retardant
Drainwire type16 AWG (19x29) TC
Outer jacket materialPVC - Polyvinyl Chloride
Outer jacket nominal thickness0.060 in (1.5 mm)
Outer jacket nominal diameter0.525 in (13.3 mm)
Overall cable diameter (nominal)0.525 in (13.3 mm)
Jacket OD +/-0.010
Bulk cable weight158 lbs/1000ft
Power pair nominal conductor DCR4.9 Ohm/1000ft
Power pair max. current8 Amps per Conductor at 25ºC
Data pair nominal conductor DCR6.9 Ohm/1000ft (23 Ohm/km)
Data pair nominal capacitance (Cond-to-Cond)14.7 pF/ft (48.2 pF/m)
Data pair nominal characteristic impedence120 Ohm
Data pair nominal delay1.6 ns/ft
Data pair nominal velocity of prop.75%
Outer shield DCR (nom)1.8 Ohm/1000ft (5.9 Ohm/km)
UL temperature75°C Dry
Operating temperature-40°C to +75°C
Installation temperature-25°C To +75°C
Bend radius (stationary min.)5 in (130 mm)
Bend radius (installation min.)5 in (130 mm)
Max Pull Tension190 lbs (86 kg)
Flammability / reaction to fireUL 1685 UL Loading, FT1
CPR complianceCPR Euroclass: Eca
NEC / UL complianceArticle 336, TC-ER
AWM complianceAWM I/II A/B
Other standard compliance(s)ODVA Cable V
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
Item TypeBelden Multi-Pair Cable
Other Part Numbers7896A T5U100, 7896A T5U250, 7896A T5U500, 7896A T5U1000
Priced PerFT