Belden 8219 010, Coax RG 58A U Type Black

SKU:Belden 8219 010
● En stock
Descripción
Belden 8219 010 is an RG-58A/U type coaxial cable designed for wireless transmission. It features a 20 AWG (19x32) TC - Tinned Copper conductor with PE - Polyethylene (Foam) insulation and a 95% Tinned Copper (TC) braid shield. A PVC - Polyvinyl Chloride jacket in Black provides protection, and the overall cable diameter (nominal) is 0.193 in (4.90 mm). Key electrical details include a nom. characteristic impedance of 54 Ohm and a UL voltage rating of 300 V (CM), 30 V (UL AWM 1354).
Belden 8219 010 Key Features
- RG type: 58 coaxial construction for wireless transmission applications.
- 20 AWG (19x32) TC - Tinned Copper conductor for a consistent signal path.
- PE - Polyethylene (Foam) insulation with White insulation color code.
- 95% Tinned Copper (TC) braid shield to support signal integrity.
- PVC - Polyvinyl Chloride jacket in Black with an overall cable diameter (nominal) of 0.193 in (4.90 mm).
- UL voltage rating: 300 V (CM), 30 V (UL AWM 1354).
Belden 8219 010 Technical Specs
Electrical & Physical Specs
| Coax construction | Coaxial |
|---|---|
| Nom. conductor diameter | 0.037 in |
| Nom. insulation diameter | 0.116 in (2.95 mm) |
| Outer shield type | Braid |
| Flooded | No not flooded over braid |
Performance & Electrical Characteristics
| Nom. velocity of prop. | 76% |
|---|---|
| Nom. capacitance cond-to-shield | 26.0 pF/ft (85.3 pF/m) |
| Nom. conductor DCR | 8.8 Ohm/1000ft |
| Nom. outer shield DCR | 4.1 Ohm/1000ft (13 Ohm/km) |
| Attenuation (nominal) 1 MHz | 0.4 dB/100ft |
| Attenuation (nominal) 10 MHz | 1.3 dB/100ft |
| Attenuation (nominal) 50 MHz | 3.1 dB/100ft |
| Attenuation (nominal) 100 MHz | 4.5 dB/100ft |
| Attenuation (nominal) 200 MHz | 6.6 dB/100ft |
| Attenuation (nominal) 400 MHz | 10.0 dB/100ft |
| Attenuation (nominal) 700 MHz | 14.2 dB/100ft |
| Attenuation (nominal) 900 MHz | 16.6 dB/100ft |
| Attenuation (nominal) 1000 MHz | 18.1 dB/100ft |
Environmental & Mechanical Ratings
| UL temperature | 80°C |
|---|---|
| Operating temperature | -40°C to +80°C |
| Installation min. bend radius | 1.9 in (48 mm) |
| Max. pull tension | 50 lbs (23 kg) |
| Bulk cable weight | 26 lbs/1000ft |
| Environmental suitability | Outdoor - Aerial, Indoor, Outdoor, UV Resistance, Aerial - When supported by messenger Wire |
Compliance & Certifications
| NEC / UL compliance | CM |
|---|---|
| CEC / C(UL) compliance | CM |
| AWM compliance | AWM 1354 |
| Flammability / reaction to fire | UL1685 UL Loading, UN ECE R118.02 |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-MSHA-SC-182/5 |
Belden 8219 010 Applications
- Point-to-point and point-to-multipoint wireless antenna communication uses this cable as a coaxial feed line between equipment and antennas.
- Wireless microphones use it to provide a coax connection for RF signal transmission.
- Two-Way Radios commonly use it to connect RF components in radio communication setups.
- Amateur (Ham) Radio systems use it for RF signal routing between radio equipment and antennas.
- Low Power FM installations apply it where coaxial cable is required for RF transmission paths.
- GPS systems use it to carry RF signals between GPS antennas and receiving equipment.
- RFID (Radio Frequency Identification) setups use it to connect RFID antennas and related RF hardware.
Belden™ and all associated trademarks are the property of their respective owners.
Especificaciones
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| Nom. conductor diameter | 0.037 in |
| Nom. insulation diameter | 0.116 in (2.95 mm) |
| Outer shield type | Braid |
| Flooded | No not flooded over braid |
| Nom. velocity of prop. | 76% |
| Nom. capacitance (Cond-to-Shield) | 26.0 pF/ft (85.3 pF/m) |
| Nom. conductor DCR | 8.8 Ohm/1000ft |
| Nom. outer shield DCR | 4.1 Ohm/1000ft (13 Ohm/km) |
| Attenuation (nominal) 1 MHz | 0.4 dB/100ft |
| Attenuation (nominal) 10 MHz | 1.3 dB/100ft |
| Attenuation (nominal) 50 MHz | 3.1 dB/100ft |
| Attenuation (nominal) 100 MHz | 4.5 dB/100ft |
| Attenuation (nominal) 200 MHz | 6.6 dB/100ft |
| Attenuation (nominal) 400 MHz | 10.0 dB/100ft |
| Attenuation (nominal) 700 MHz | 14.2 dB/100ft |
| Attenuation (nominal) 900 MHz | 16.6 dB/100ft |
| Attenuation (nominal) 1000 MHz | 18.1 dB/100ft |
| UL temperature | 80°C |
| Operating temperature | -40°C to +80°C |
| Installation min. bend radius | 1.9 in (48 mm) |
| Max Pull Tension | 50 lbs (23 kg) |
| Bulk cable weight | 26 lbs/1000ft |
| Environmental suitability | Outdoor - Aerial, Indoor, Outdoor, UV Resistance, Aerial - When supported by messenger Wire |
| NEC / UL compliance | CM |
| CEC / C(UL) compliance | CM |
| AWM compliance | AWM 1354 |
| Flammability / reaction to fire | UL1685 UL Loading, UN ECE R118.02 |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-MSHA-SC-182/5 |
| Priced Per | FT |
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.
¿Necesita un corte a medida, precio por volumen o una ficha técnica?
Nuestro equipo cotiza largos personalizados y pedidos por volumen, normalmente el mismo día.