Belden 8760 060U 2 conductor 18AWG blindaje Gray PVC cubierta

SKU:Belden 8760 060U
$204.00
● En stock
Descripción
Belden 8760 060U es una cable de 2 conductor 18AWG (16x30) con aislamiento PE, un blindajeBeldfoil® general y una cubiertaexterior PVC gris. Está clasificado como CM y se suministra sin enrollar.
Aplicaciones
- Úsalo donde se necesita una construcción apantallado cable para mantener la integridad de la señal.
- Elige este cable para las etapas que requieren un cableclasificado para CM.
- Seleccione cable sin enrollar al cortar y manipular durante la instalación.
Especificaciones
| Attribute | Value |
|---|---|
| Pairs | 1 |
| Conductor size | 18 AWG |
| Stranding | 16x30 |
| Conductor Material | TC - Tinned Copper |
| Insulation thickness (nom.) | 0.018 in (0.46 mm) |
| Insulation diameter (nom.) | 0.082 in (2.1 mm) |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield construction | Aluminum Foil-Polyester Tape w/ Shorting Fold |
| Drainwire type | 20 AWG (7x28) TC |
| Drain wire position | Drain Wire is on the outside of the Foil Shield |
| Jacket thickness (nom.) | 0.028 in (0.71 mm) |
| Overall cable diameter (nom.) | 0.222 in (5.64 mm) |
| Bulk cable weight | 25 lbs/1000ft |
| Conductor DCR (nom.) | 7.06 Ohm/1000ft |
| Outer shield DCR (nom) | 8.49 Ohm/1000ft (27.9 Ohm/km) |
| Capacitance, Cond-to-Cond (nom.) | 27.2 pF/ft (89.2 pF/m) |
| Inductance (nom.) | 0.18 µH/ft (0.59 µH/m) |
| Max. current | 14 Amps per Conductor at 30ºC |
| Operating temperature | -20°C to +60°C |
| UL temperature | 60°C |
| Stationary min. bend radius | 2.2 in (56 mm) |
| Installation min. bend radius | 2.2 in (56 mm) |
| Max Pull Tension | 54.2 lbs (24.6 kg) |
| Environmental suitability | Indoor |
| NEC / UL compliance | Article 800, CM |
| AWM compliance | AWM 2092 |
| CEC / C(UL) compliance | CM |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| Plenum number | 88760, 87760 or 82760 |
| Item Type | Belden Multi-Pair Cable |
| Other Part Numbers | 8760 060100, 8760 060250, 8760 060500, 8760 0601000 |
| Priced Per | FT |
Documentos
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.
¿Necesita un corte a medida, precio por volumen o una ficha técnica?
Nuestro equipo cotiza largos personalizados y pedidos por volumen, normalmente el mismo día.