Belden 9418 060, Multi Conductor Cable 4C 18 AWG FEP Flamarrest

Descripción
Belden 9418 060 is a 4-conductor 18 AWG multi-conductor cable designed for low-voltage signal and control wiring in panels and indoor installations. It uses 19x30 stranded tinned copper conductors with SR-PVC insulation and an overall Beldfoil® tape shield with 100% coverage, plus a 20 AWG (19x32) tinned copper drain wire. A PVC outer jacket and a nominal 0.245 in (6.22 mm) overall diameter support clean routing and consistent handling. UL voltage rating is 300 V (CMG), 300 V (UL AWM 2464).
Belden 9418 060 Key Features
- 4 conductors in 18 AWG for low-voltage signal and control wiring.
- 19x30 stranded tinned copper conductors with SR-PVC - Polyvinyl Chloride (Semi-Rigid) insulation.
- Overall Beldfoil® tape shield with 100% coverage and a 20 AWG (19x32) TC drainwire for shielding continuity.
- PVC - Polyvinyl Chloride outer jacket with a nominal 0.245 in (6.22 mm) overall cable diameter.
- UL voltage rating: 300 V (CMG), 300 V (UL AWM 2464).
Belden 9418 060 Technical Specs
Construction & Physical Specs
| Conductor material | TC - Tinned Copper |
|---|---|
| Insulation thickness (nom.) | 0.011 in (0.28 mm) |
| Insulation diameter (nom.) | 0.066 in (1.7 mm) |
| Color code | Red, Green, Black, White |
| Jacket thickness (nom.) | 0.035 in (0.89 mm) |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
Electrical Characteristics
| Nom. conductor DCR | 6.5 Ohm/1000ft |
|---|---|
| Nom. capacitance cond-to-cond | 40 pF/ft (130 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 72 pF/ft (240 pF/m) |
| Max. current | 5 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 8.5 Ohm/1000ft (28 Ohm/km) |
Environmental & Mechanical Ratings
| UL temperature | 80°C |
|---|---|
| Operating temperature | -20°C to +80°C |
| Bend radius (stationary min.) | 2.5 in (64 mm) |
| Bend radius (installation min.) | 2.5 in (64 mm) |
| Max. pull tension | 113 lbs (51.3 kg) |
| Bulk cable weight | 42 lbs/1000ft |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
Compliance & Certifications
| NEC / UL compliance | Article 800, CMG |
|---|---|
| CEC / C(UL) compliance | CMG |
| AWM compliance | AWM 2464 |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| Sustainability | CA Prop 65 |
| Plenum number | 89418 or 82418 |
Belden 9418 060 Applications
- Use it for low voltage analog signals (4-20ma, 0-10v, ...) where consistent signal transfer is needed in indoor wiring runs.
- Wire low voltage control (24v, …) circuits in panels to support organized control and signal routing.
- Choose it for line level audio connections where shielded multi-conductor wiring is desired for indoor installations.
- Route voice communications wiring through panels and indoor pathways using this construction.
- Apply it in panel wiring where a multi-conductor design supports clean routing and consistent handling.
Belden™ and all associated trademarks are the property of their respective owners.
Especificaciones
| Attribute | Value |
|---|---|
| Conductor Material | TC - Tinned Copper |
| Insulation thickness (nom.) | 0.011 in (0.28 mm) |
| Insulation diameter (nom.) | 0.066 in (1.7 mm) |
| Color Code | Red, Green, Black, White |
| Jacket thickness (nom.) | 0.035 in (0.89 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Nom. conductor DCR | 6.5 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 40 pF/ft (130 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 72 pF/ft (240 pF/m) |
| Max. current | 5 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 8.5 Ohm/1000ft (28 Ohm/km) |
| UL temperature | 80°C |
| Operating temperature | -20°C to +80°C |
| Bend radius (stationary min.) | 2.5 in (64 mm) |
| Bend radius (installation min.) | 2.5 in (64 mm) |
| Max Pull Tension | 113 lbs (51.3 kg) |
| Bulk cable weight | 42 lbs/1000ft |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| NEC / UL compliance | Article 800, CMG |
| CEC / C(UL) compliance | CMG |
| AWM compliance | AWM 2464 |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| Sustainability | CA Prop 65 |
| Plenum number | 89418 or 82418 |
| Priced Per | FT |