Belden 9451 008U is a 1 pair 22 AWG audio/control cable designed for reliable signal transmission in panel wiring, computer communication, and line level audio applications. It uses 22 AWG Stranded (7x30) TC - Tinned Copper conductors with PP - Polypropylene insulation and an overall Beldfoil® tape shield with 100% coverage plus a 22 AWG (7x30) TC drain wire. The PVC - Polyvinyl Chloride jacket is bonded to the shield to support automatic stripping equipment and faster terminations. UL Voltage Rating is 300 V (CMR) with UL 1666 Riser performance for Indoor - Riser installations.
Belden 9451 008U Key Features
- 1 pair construction with 22 AWG Stranded (7x30) TC - Tinned Copper conductors.
- PP - Polypropylene insulation with Black & Red color code.
- Overall Beldfoil® tape shield with 100% coverage and a 22 AWG (7x30) TC drain wire.
- PVC - Polyvinyl Chloride jacket bonded to the shield to support automatic stripping equipment and faster terminations.
- UL Voltage Rating: 300 V (CMR) with UL 1666 Riser performance.
Belden 9451 008U Technical Specs
Physical Construction
| Insulation thickness | 0.009 in (0.23 mm) |
|---|---|
| Insulation diameter | 0.046 in (1.2 mm) |
| Jacket thickness | 0.020 in (0.51 mm) |
| Overall diameter | 0.135 in (3.43 mm) |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Bulk Cable Weight | 14 lbs/1000ft (21 kg/km) |
| Plenum number | 9451P |
Electrical Characteristics
| Nom. Conductor DCR | 14.1 Ohm/1000ft (46.3 Ohm/km) |
|---|---|
| Nom outer Shield DCR | 14.3 Ohm/1000ft (46.9 Ohm/km) |
| Nom. capacitance Cond-to-Cond | 35 pF/ft (110 pF/m) |
| Nom. capacitance Cond-to-other (conds + Shield) | 67 pF/ft (220 pF/m) |
| Nom. characteristic impedence | 45 Ohm |
| Nom. delay | 1.54 ns/ft |
| Nom. inductance | 0.17 μH/ft (0.56 μH/m) |
| Nom. velocity of prop. | 66% |
| Max. current | 2.9 Amps per Conductor at 25ºC |
Environmental & Mechanical Ratings
| UL temperature | 60°C |
|---|---|
| Operating temperature | -20°C to +75°C |
| Bend Radius (stationary min.) | 1.4 in (36 mm) |
| Bend Radius (installation min.) | 1.4 in (36 mm) |
| Max. pull tension | 27 lbs (12 kg) |
| Environmental suitability | Indoor - Riser, Indoor |
Compliance & Certifications
| Flammability / reaction to fire | UL 1666 Riser, IEEE 1202 FT4, IEC 60332-1-2 |
|---|---|
| NEC / UL compliance | Article 800, CMR |
| CEC / C(UL) compliance | CMR |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
Belden 9451 008U Applications
- Supports automatic stripping equipment where the jacket and shield can be removed together for faster terminations.
- Handles low voltage analog signals (4-20mA, 0-10V, ...) in control and signal transmission tasks.
- Works with low voltage digital control (24V, …) in control wiring setups.
- Fits line level audio connections where consistent signal transmission is needed.
- Enables signal transmission in computer communication links.
- Installs in indoor panel wiring, including Indoor - Riser locations.
Belden™ and all associated trademarks are the property of their respective owners.
Especificaciones
| Attribute | Value |
|---|---|
| Insulation Thickness | 0.009 in (0.23 mm) |
| Insulation Diameter | 0.046 in (1.2 mm) |
| Jacket Thickness | 0.020 in (0.51 mm) |
| Overall Diameter | 0.135 in (3.43 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Bulk cable weight | 14 lbs/1000ft (21 kg/km) |
| Plenum number | 9451P |
| Nom. conductor DCR | 14.1 Ohm/1000ft (46.3 Ohm/km) |
| Nom. outer shield DCR | 14.3 Ohm/1000ft (46.9 Ohm/km) |
| Nom. capacitance cond-to-cond | 35 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 67 pF/ft (220 pF/m) |
| Nom. characteristic impedence | 45 Ohm |
| Nom. delay | 1.54 ns/ft |
| Nom. inductance | 0.17 µH/ft (0.56 µH/m) |
| Nom. velocity of prop. | 66% |
| Max. current | 2.9 Amps per Conductor at 25ºC |
| UL temperature | 60°C |
| Operating temperature | -20°C to +75°C |
| Bend radius (stationary min.) | 1.4 in (36 mm) |
| Bend radius (installation min.) | 1.4 in (36 mm) |
| Max Pull Tension | 27 lbs (12 kg) |
| Environmental suitability | Indoor - Riser, Indoor |
| Flammability / reaction to fire | UL 1666 Riser, IEEE 1202 FT4, IEC 60332-1-2 |
| NEC / UL compliance | Article 800, CMR |
| CEC / C(UL) compliance | CMR |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Priced Per | FT |