Belden 9460 060U, Multi Pair Cable 1 Pair 18 AWG PE PVC Jacket

SKU:Belden 9460 060U
● En stock
Descripción
Belden 9460 060U is a 1 pair 18 AWG control, instrumentation, and audio cable designed for low-voltage signal transmission in panel wiring, computer communication, and line level audio. It features 18AWG (16x30) tinned copper conductors with PE insulation and an overall Beldfoil® shield for noise rejection. A PVC outer jacket with CM rating supports indoor general-purpose installations, while the bonded jacket and shield are designed to strip cleanly on automatic stripping equipment.
Belden 9460 060U Key Features
- The 1 pair 18 AWG construction supports control, instrumentation, and audio signal wiring.
- 18AWG (16x30) tinned copper conductors with PE insulation.
- An overall Beldfoil® shield provides noise rejection.
- The bonded jacket and shield help enable clean removal on automatic stripping equipment.
- Foil-in construction positions the drain wire on the inside of the shield.
- A PVC outer jacket with CM rating supports indoor general-purpose installations.
Belden 9460 060U Technical Specs
Construction & Materials
| Number of pairs | 1 |
|---|---|
| Conductor size | 18 AWG |
| Stranding | 16x30 |
| Conductor material | TC - Tinned Copper |
| Insulation material | PE - Polyethylene |
| Nom. thickness (insulation) | 0.018 in (0.46 mm) |
| Nom. insulation diameter | 0.082 in (2.1 mm) |
| Color code | Black & Clear |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield coverage | 100% |
| Drainwire type | 20 AWG (7x28) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Nom. thickness (jacket) | 0.030 in (0.76 mm) |
Physical Dimensions & Weight
| Nom. diameter | 0.230 in (5.84 mm) |
|---|---|
| Overall cable diameter (nominal) | 0.230 in (5.84 mm) |
| Bulk cable weight | 34 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. conductor DCR | 6.5 Ohm/1000ft |
|---|---|
| Nom. capacitance cond-to-cond | 29.8 pF/ft (97.8 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 44 pF/ft (140 pF/m) |
| Nom. characteristic impedence | 57 Ohm |
| Nom. inductance | 0.18 μH/ft (0.59 μH/m) |
| Max. current | 5.2 Amps per Conductor at 25ºC |
| UL voltage rating | 300 V (CM) |
Environmental & Mechanical Ratings
| UL temperature | 60°C |
|---|---|
| Operating temperature | -20°C to +60°C |
| Bend radius (stationary min.) | 2.3 in (58 mm) |
| Bend radius (installation min.) | 2.3 in (58 mm) |
| Max. pull tension | 62 lbs (28 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
Compliance & Certifications
| NEC / UL compliance | Article 800, CM |
|---|---|
| CEC / C(UL) compliance | CM |
| CPR compliance | CPR Euroclass: Eca |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 9460 060U Applications
- Use it with automatic stripping equipments where clean jacket and shield removal is needed.
- Support low voltage analog signals (4-20ma, 0-10v, ...) in control and instrumentation circuits.
- Use it for low voltage digital control (24v, …) in automation and control wiring.
- Connect line level audio signals.
- Fit computer communication signal wiring where shielded signal cable is required.
- Install it for panel wiring in indoor installations.
Belden™ and all associated trademarks are the property of their respective owners.
Especificaciones
| Attribute | Value |
|---|---|
| Number of pairs | 1 |
| Conductor size | 18 AWG |
| Stranding | 16x30 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PE - Polyethylene |
| Nom. thickness (insulation) | 0.018 in (0.46 mm) |
| Nom. insulation diameter | 0.082 in (2.1 mm) |
| Color Code | Black & Clear |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 20 AWG (7x28) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Nom. thickness (jacket) | 0.030 in (0.76 mm) |
| Nom. diameter | 0.230 in (5.84 mm) |
| Overall cable diameter (nominal) | 0.230 in (5.84 mm) |
| Bulk cable weight | 34 lbs/1000ft |
| Nom. conductor DCR | 6.5 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 29.8 pF/ft (97.8 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 44 pF/ft (140 pF/m) |
| Nom. characteristic impedence | 57 Ohm |
| Nom. inductance | 0.18 µH/ft (0.59 µH/m) |
| Max. current | 5.2 Amps per Conductor at 25ºC |
| UL Voltage Rating | 300 V (CM) |
| UL temperature | 60°C |
| Operating temperature | -20°C to +60°C |
| Bend radius (stationary min.) | 2.3 in (58 mm) |
| Bend radius (installation min.) | 2.3 in (58 mm) |
| Max Pull Tension | 62 lbs (28 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
| NEC / UL compliance | Article 800, CM |
| CEC / C(UL) compliance | CM |
| CPR compliance | CPR Euroclass: Eca |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.
¿Necesita un corte a medida, precio por volumen o una ficha técnica?
Nuestro equipo cotiza largos personalizados y pedidos por volumen, normalmente el mismo día.