Belden 9462 060, Multi Pair Cable 1 Pair 22 AWG PVC Jacket

Descripción
Belden 9462 060 is a 1 pair, 22 AWG shielded multi-conductor cable with a PVC outer jacket and CMG rating for indoor installations. It is built with 2 Stranded 22AWG (7x30) Tinned Copper Conductors and PVC insulation, plus an overall Beldfoil® shield with a drainwire to help reduce noise and interference. UL Voltage Rating is 300 V (CMG), 300 V (UL AWM 2464), with an operating range of -30°C to +80°C.
Belden 9462 060 Key Features
- 1 pair construction with 2 conductors in 22 AWG for signal and control wiring.
- 2 Stranded 22AWG (7x30) TC - Tinned Copper conductors for flexibility.
- PVC - Polyvinyl Chloride insulation and PVC - Polyvinyl Chloride outer jacket.
- Overall Beldfoil® shield with drainwire; shield type: tape; coverage: 100%; notes: Foil-Out.
- UL Voltage Rating: 300 V (CMG), 300 V (UL AWM 2464).
- Operating: -30°C to +80°C; UL temperature: 80°C.
- Environmental suitability: indoor (not riser or plenum), indoor.
Belden 9462 060 Technical Specs
Construction & Materials
| Number of conductors | 2 |
|---|---|
| Conductor size | 22 AWG |
| Conductor stranding | 7x30 |
| Conductor material | TC - Tinned Copper |
| Insulation material | PVC - Polyvinyl Chloride |
| Nom. thickness (insulation) | 0.0155 in (0.394 mm) |
| Nom. insulation diameter | 0.060 in (1.5 mm) |
| Color code | Black, Red |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Nom. thickness (outer jacket) | 0.035 in (0.89 mm) |
| Nom. diameter (outer jacket) | 0.194 in (4.93 mm) |
| Overall cable diameter (nominal) | 0.194 in (4.93 mm) |
| Shield material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 22 AWG (7x30) TC |
| Shield construction | Overall Shield & drain |
Performance & Electrical Characteristics
| Nom. conductor DCR | 16 Ohm/1000ft |
|---|---|
| Nom. capacitance cond-to-cond | 50 pF/ft (160 pF/m) |
| Nom. capacitance cond-to-other (Conds + Shield) | 90 pF/ft (300 pF/m) |
| Nom. characteristic impedence | 36 Ohm |
| Nom. inductance | 0.19 μH/ft (0.62 μH/m) |
| Max. current | 3 Amps per Conductor at 25ºC |
Mechanical Ratings
| Stationary min. bend radius | 1.9 in (48 mm) |
|---|---|
| Installation min. bend radius | 1.9 in (48 mm) |
| Max. pull tension | 27 lbs (12 kg) |
| Bulk cable weight | 19 lbs/1000ft |
Compliance & Certifications
| NEC / UL compliance | Article 800, CMG |
|---|---|
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 9462 060 Applications
- Commonly used for low voltage analog signals (4-20ma, 0-10v, ...) in instrumentation and control circuits.
- Supports low voltage digital control (24v, …) where shielded signal wiring is needed.
- Suitable for line level audio connections where clean signal transmission is required.
- Used for computer communication links in systems that specify this cable type.
- Often used for panel wiring in control panels and related equipment.
Belden™ and all associated trademarks are the property of their respective owners.
Especificaciones
| Attribute | Value |
|---|---|
| Number of Conductors | 2 |
| Conductor size | 22 AWG |
| Conductor stranding | 7x30 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. thickness (insulation) | 0.0155 in (0.394 mm) |
| Nom. insulation diameter | 0.060 in (1.5 mm) |
| Color Code | Black, Red |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Nom. thickness (outer jacket) | 0.035 in (0.89 mm) |
| Nom. diameter (outer jacket) | 0.194 in (4.93 mm) |
| Overall cable diameter (nominal) | 0.194 in (4.93 mm) |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 22 AWG (7x30) TC |
| Shield construction | Overall Shield & drain |
| Nom. conductor DCR | 16 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 50 pF/ft (160 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 90 pF/ft (300 pF/m) |
| Nom. characteristic impedence | 36 Ohm |
| Nom. inductance | 0.19 µH/ft (0.62 µH/m) |
| Max. current | 3 Amps per Conductor at 25ºC |
| Stationary min. bend radius | 1.9 in (48 mm) |
| Installation min. bend radius | 1.9 in (48 mm) |
| Max Pull Tension | 27 lbs (12 kg) |
| Bulk cable weight | 19 lbs/1000ft |
| NEC / UL compliance | Article 800, CMG |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.
¿Necesita un corte a medida, precio por volumen o una ficha técnica?
Nuestro equipo cotiza largos personalizados y pedidos por volumen, normalmente el mismo día.