Belden 9918 001 is a low temp plastic lead wire for internal wiring in electronic and electrical equipment. It is a 1-conductor 18 AWG (16x30) TC - Tinned Copper wire with PVC - Polyvinyl Chloride insulation. This hook up wire is rated 105°C and 300 V RMS, with a max current of 20 A for a single conductor in free air @ 30ºC. It meets VW-1 flammability and includes AWM 1007, AWM 1569, and regional compliance listings for indoor use.
Belden 9918 001 Technical Specs
Construction & Physical Specs
| Number of conductors | 1 |
|---|---|
| Wire size | 18 AWG |
| Conductor stranding | 16x30 |
| Conductor material | TC - Tinned Copper |
| Insulation material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.017 in (0.43 mm) |
| Nom. insulation diameter | 0.079 in (2.0 mm) |
| Overall cable diameter (nominal) | 0.079 in (2.0 mm) |
| Bulk cable weight | 7 lbs/1000ft |
Electrical Characteristics
| UL voltage rating | 300 V RMS |
|---|---|
| Nom. conductor DCR | 7.15 Ohm/1000ft |
| Max. current | Single conductor in free air @ 30ºC: 20 A |
Environmental & Mechanical Ratings
| UL temperature | 105°C |
|---|---|
| Operating temperature range | -25°C To +105°C |
| Minimum bend radius (stationary) | 0.79 in (20 mm) |
| Minimum bend radius (installation) | 0.79 in (20 mm) |
| Max. pull tension | 21 lbs (9.5 kg) |
| Environmental suitability | Indoor |
| Flammability / reaction to fire | VW-1 |
Compliance & Certifications
| AWM compliance | AWM 1007, AWM 1569 |
|---|---|
| CEC / C(UL) compliance | TRSR-64 |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 9918 001 Applications
- Use it for inter-connection circuits where dependable internal point-to-point wiring is required within electronic or electrical equipment.
- Support internal wiring of computer and electronic equipments to help route power or signal connections inside enclosures.
- Choose it for internal wiring of appliances where insulated lead wire is needed for equipment interconnects.
Belden™ and all associated trademarks are the property of their respective owners.
Especificaciones
| Attribute | Value |
|---|---|
| Number of Conductors | 1 |
| Wire size | 18 AWG |
| Conductor stranding | 16x30 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.017 in (0.43 mm) |
| Nom. insulation diameter | 0.079 in (2.0 mm) |
| Overall cable diameter (nominal) | 0.079 in (2.0 mm) |
| Bulk cable weight | 7 lbs/1000ft |
| UL Voltage Rating | 300 V RMS |
| Nom. conductor DCR | 7.15 Ohm/1000ft |
| Max. current | Single conductor in free air @ 30ºC: 20 A |
| UL temperature | 105°C |
| Operating Temperature Range | -25°C To +105°C |
| Minimum bend radius (stationary) | 0.79 in (20 mm) |
| Minimum bend radius (installation) | 0.79 in (20 mm) |
| Max Pull Tension | 21 lbs (9.5 kg) |
| Environmental suitability | Indoor |
| Flammability / reaction to fire | VW-1 |
| AWM compliance | AWM 1007, AWM 1569 |
| CEC / C(UL) compliance | TRSR-64 |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |