Belden 9921 005, Hook Up Wire 1C 22 AWG Tinned Copper PVC

Descripción
Belden 9921 005 is a low temp plastic lead wire built with a 1-conductor 22 AWG (7x30) TC - Tinned Copper conductor and PVC - Polyvinyl Chloride insulation. This hook up wire is rated 105°C and 300 V RMS, with a max current of 11 A for a single conductor in free air @ 30ºC. It meets AWM 1007 and AWM 1569 requirements and carries a VW-1 flammability rating for indoor applications.
Belden 9921 005 Key Features
- 1-conductor 22 AWG (7x30) TC - Tinned Copper construction for internal wiring and inter-connection circuits.
- PVC - Polyvinyl Chloride insulation with 0.017 in (0.43 mm) nominal thickness.
- Rated 105°C and 300 V RMS for electrical wiring applications.
- Meets AWM 1007 and AWM 1569, with VW-1 flammability / reaction to fire.
- Environmental suitability: indoor.
Belden 9921 005 Technical Specs
Construction & Dimensions
| Conductor count | 1 |
|---|---|
| Conductor size | 22 AWG |
| Conductor stranding | 7x30 |
| Conductor material | TC - Tinned Copper |
| Insulation material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.017 in (0.43 mm) |
| Nom. insulation diameter | 0.062 in (1.6 mm) |
| Overall cable diameter (nominal) | 0.062 in (1.6 mm) |
Electrical & Performance Characteristics
| Nom. conductor DCR | 18.1 Ohm/1000ft |
|---|---|
| Max. current | Single conductor in free air @ 30ºC: 11 A |
| Nom. insertion loss (attenuation) | 6.2 dB/100m |
| Nom. insertion loss (attenuation) | 6.1 dB/100m |
| Typical unbalanced FEXT % | 6.2 MHz |
Environmental & Mechanical Ratings
| Operating temperature | -20°C to +105°C |
|---|---|
| Bend radius (stationary min.) | 0.62 in (16 mm) |
| Bend radius (installation min.) | 0.62 in (16 mm) |
| Max. pull tension | 9 lbs (4.1 kg) |
| Bulk cable weight | 4 lbs/1000ft |
Compliance & Certifications
| CEC / C(UL) compliance | TRSR-64 |
|---|---|
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 9921 005 Applications
- Use it for inter-connection circuits where reliable internal wiring is required.
- Support internal wiring of computer and electronic equipments in enclosed, indoor environments.
- Choose it for internal wiring of appliances where compact routing and stable connections are needed.
Belden™ and all associated trademarks are the property of their respective owners.
Especificaciones
| Attribute | Value |
|---|---|
| Conductor count | 1 |
| Conductor size | 22 AWG |
| Conductor stranding | 7x30 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.017 in (0.43 mm) |
| Nom. insulation diameter | 0.062 in (1.6 mm) |
| Overall cable diameter (nominal) | 0.062 in (1.6 mm) |
| Nom. conductor DCR | 18.1 Ohm/1000ft |
| Max. current | Single conductor in free air @ 30ºC: 11 A |
| Nom. insertion loss (attenuation) | 6.2 dB/100m; 6.1 dB/100m |
| Typical unbalanced FEXT % | 6.2 MHz |
| Operating temperature | -20°C to +105°C |
| Bend radius (stationary min.) | 0.62 in (16 mm) |
| Bend radius (installation min.) | 0.62 in (16 mm) |
| Max Pull Tension | 9 lbs (4.1 kg) |
| Bulk cable weight | 4 lbs/1000ft |
| CEC / C(UL) compliance | TRSR-64 |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.
¿Necesita un corte a medida, precio por volumen o una ficha técnica?
Nuestro equipo cotiza largos personalizados y pedidos por volumen, normalmente el mismo día.