Belden BAV 1392A 010 is a Lighting & Automation Cable designed to combine power and data in one run for indoor riser installations. It is Riser-CMR rated and built with 2-18 AWG Bare Copper Conductors (Unshielded) plus 1 Shielded (data) pair 22 AWG Stranded Bare Copper with a 100% tape Shield and Drain Wire. The cable uses a PVC - Polyvinyl Chloride outer jacket with ripcord and carries a UL voltage rating of 300 V. It has a nominal 0.25 in overall diameter and meets UL1666 Riser / FT4 flame performance.
Key Features
- Composite design combines power and data conductors in a single cable run.
- Riser-CMR construction for indoor - riser, indoor installations.
- Conductor mix includes 2-18 AWG Bare Copper Conductors (Unshielded) plus 1 Shielded (data) pair 22 AWG Stranded Bare Copper.
- Inner shield is tape, bi-laminate (Alum+Poly), 100% coverage with Drainwire: 24 AWG (7x32) TC.
- PVC - Polyvinyl Chloride outer jacket with ripcord: Yes, for easier pulls and stripping.
- UL voltage rating: 300 V.
- Flammability / reaction to fire: UL1666 Riser, FT4, IEEE 1202 FT4.
Technical Specs
General
| Cable type | Lighting & Automation Cable |
|---|---|
| Rating | Riser-CMR |
| Environmental suitability | Indoor - Riser, Indoor |
Conductors & Insulation
| Power conductors | 2-18 AWG Bare Copper Conductors Unshielded |
|---|---|
| 18 AWG stranding | 16x30 Stranding, BC - Bare Copper (2 Conductors) |
| 18 AWG insulation | PVC - Polyvinyl Chloride, 0.013 in (0.33 mm) nominal thickness, 0.073 in (1.9 mm) nominal insulation diameter, color code Black, Red |
| Power insulation | PVC Insulation (power) |
| Data pair | 1 Shielded (data) pair 22 AWG Stranded Bare Copper |
| 22 AWG stranding | 7x30 Stranding, BC - Bare Copper (2 Conductors) |
| 22 AWG insulation | PE - Polyethylene (Foam), 0.025 in (0.64 mm) nominal thickness, 0.079 in (2.0 mm) nominal insulation diameter, color code White, Blue |
| Data pair insulation | PVC Insulation |
Shielding
| Outer shield | No Shield |
|---|
Jacket & Dimensions
| Jacket | PVC - Polyvinyl Chloride |
|---|---|
| Jacket nominal thickness | 0.0385 in (0.978 mm) |
| Nominal jacket diameter | 0.25 in |
| Overall cable diameter (nominal) | 0.25 in |
Performance & Electrical Characteristics
| 22 AWG nominal conductor DCR | 17.2 Ohm/1000ft |
|---|---|
| 22 AWG nominal inner shield DCR | 18.38 Ohm/1000ft (60.30 Ohm/km) |
| 22 AWG nominal capacitance cond-to-cond | 14 pF/ft (46 pF/m) |
| 22 AWG nominal capacitance cond-to-other (Conds + Shield) | 25.2 pF/ft (82.7 pF/m) |
| 22 AWG nominal characteristic impedence | 100 Ohm |
| 22 AWG max. current | 6 Amps per Conductor at 30ºC |
| 18 AWG nominal conductor DCR | 6.79 Ohm/1000ft (22.3 Ohm/km) |
| 18 AWG nominal capacitance cond-to-cond | 29 pF/ft (95 pF/m) |
| 18 AWG max. current | 4.8 Amps per Conductor at 30ºC |
Environmental & Mechanical Ratings
| UL temperature | 60°C |
|---|---|
| Operating temperature | -20°C to +60°C |
| Bend radius (stationary min.) | 2.5 in (64 mm) |
| Bend radius (installation min.) | 2.5 in |
| Max. pull tension | 65.3 lbs (29.6 kg) |
| Bulk cable weight | 38lbs/1000ft |
Compliance & Certifications
| NEC / UL compliance | Article 800, CMR |
|---|---|
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Plenum number | 1392P |
Applications
- Supports automation/control installations where power and data are routed together.
Belden BAV™ and all associated trademarks are the property of their respective owners.
Especificaciones
| Attribute | Value |
|---|---|
| Cable type | Lighting & Automation Cable |
| Rating | Riser-CMR |
| Environmental suitability | Indoor - Riser, Indoor |
| Power conductors | 2-18 AWG Bare Copper Conductors Unshielded |
| 18 AWG stranding | 16x30 Stranding, BC - Bare Copper (2 Conductors) |
| 18 AWG insulation | PVC - Polyvinyl Chloride, 0.013 in (0.33 mm) nominal thickness, 0.073 in (1.9 mm) nominal insulation diameter, color code Black, Red |
| Power insulation | PVC Insulation (power) |
| Data pair | 1 Shielded (data) pair 22 AWG Stranded Bare Copper |
| 22 AWG stranding | 7x30 Stranding, BC - Bare Copper (2 Conductors) |
| 22 AWG insulation | PE - Polyethylene (Foam), 0.025 in (0.64 mm) nominal thickness, 0.079 in (2.0 mm) nominal insulation diameter, color code White, Blue |
| Data pair insulation | PVC Insulation |
| Outer shield | No Shield |
| Jacket | PVC - Polyvinyl Chloride |
| Jacket nominal thickness | 0.0385 in (0.978 mm) |
| Nominal jacket diameter | 0.25 in |
| Overall cable diameter (nominal) | 0.25 in |
| 22 AWG nominal conductor DCR | 17.2 Ohm/1000ft |
| 22 AWG nominal inner shield DCR | 18.38 Ohm/1000ft (60.30 Ohm/km) |
| 22 AWG nominal capacitance cond-to-cond | 14 pF/ft (46 pF/m) |
| 22 AWG nominal capacitance cond-to-other (Conds + Shield) | 25.2 pF/ft (82.7 pF/m) |
| 22 AWG nominal characteristic impedence | 100 Ohm |
| 22 AWG max. current | 6 Amps per Conductor at 30ºC |
| 18 AWG nominal conductor DCR | 6.79 Ohm/1000ft (22.3 Ohm/km) |
| 18 AWG nominal capacitance cond-to-cond | 29 pF/ft (95 pF/m) |
| 18 AWG max. current | 4.8 Amps per Conductor at 30ºC |
| UL temperature | 60°C |
| Operating temperature | -20°C to +60°C |
| Bend radius (stationary min.) | 2.5 in (64 mm) |
| Bend radius (installation min.) | 2.5 in |
| Max Pull Tension | 65.3 lbs (29.6 kg) |
| Bulk cable weight | 38lbs/1000ft |
| NEC / UL compliance | Article 800, CMR |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Plenum number | 1392P |
| Priced Per | FT |
Las imágenes son solo de referencia. Las especificaciones pueden cambiar sin previo aviso — verifique la idoneidad para su aplicación antes de comprar. La documentación del fabricante prevalece.
¿Necesita un corte a medida, precio por volumen o una ficha técnica?
Nuestro equipo cotiza largos personalizados y pedidos por volumen, normalmente el mismo día.