Belden 1012A 4 paires 20 AWG SPOS KX Type

1012A

SKU:Belden 1012A

$1,228.80

En stock

Description

Spécifications

Belden 1012A 4 paires 20 AWG SPOS KX Type specifications
AttributeValue
Thermocouple typeChromel/Alumel Type KX
TypeType KX Thermocouple
Pairs4
Pair Conductor Size20 AWG
Pair StrandingSolid
Pair Conductor MaterialChromel & Alumel
Comm1
Comm size22 AWG
Comm Stranding7x30
Comm materialBC - Bare Copper
Insulation MaterialPVC - Polyvinyl Chloride
Pair nominal thickness0.021 in (0.53 mm)
Pair nominal Insulation Diameter0.074 in (1.9 mm)
Pair color codeYellow and Red Numbered 1, Yellow and Red Numbered 2, Yellow and Red Numbered 3, Yellow and Red Numbered 4
Comm nominal thickness0.019 in (0.48 mm)
Comm nominal Insulation Diameter0.066 in (1.7 mm)
Comm color codeOrange
Outer jacket materialPVC - Polyvinyl Chloride
Jacket ColorYellow
SeparatorPolyester Tape
Outer jacket nominal thickness0.053 in (1.3 mm)
Overall cable diameter (nominal)0.447 in
RipcordYes
ArmorNo
Bulk cable weight83 lbs/1000ft
ShieldingIndividual & Overall Beldfoil® Shield
Inner shield typeTape
Inner shield materialBi-Laminate (Alum+Poly)
Inner shield coverage100%
Inner Shield drainwire type22 AWG (7x30) TC
Inner Shield notesPolyster Flim
Outer shield typeTape
Outer shield materialBi-Laminate (Alum+Poly)
Outer shield coverage100%
Outer Shield drainwire type20 AWG (7x28) TC
Chromel nominal Conductor DCR420 Ohm/1000ft
Chromel nominal inner Shield DCR12.3 Ohm/1000ft (40.4 Ohm/km)
Chromel max. current2.8 Amps per Conductor at 30ºC
Alumel nominal Conductor DCR161 Ohm/1000ft (528 Ohm/km)
Alumel max. current2.8 Amps per Conductor at 30ºC
Comm nominal Conductor DCR18.5 Ohm/1000ft (60.7 Ohm/km)
Comm max. current4.8 Amps per Conductor at 30ºC
Nom. outer shield DCR5.8 Ohm/1000ft (19 Ohm/km)
UL temperatureUL: 105°C, AWM 2464: 80°C
Operating-20°C To +105°C
Stationary min. bend radius4.47 in (114 mm)
Installation min. bend radius4.47 in
Max Pull Tension635 lbs (288 kg)
Environmental suitabilityIndoor, Outdoor, Sunlight Resistance, UV Resistance, Burial
Flammability / reaction to fireUL1685 FT4 Loading, FT4, IEEE 1202 FT4
NEC / UL complianceArticle 725, Article 727, Article 800
AWM complianceAWM 2464
CEC / C(UL) complianceCMG
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC complianceChina RoHS II (GB/T 26572-2011)
Item TypeBelden Thermocouple Wire
Other Part Numbers1012A 004, 1012A 004100, 1012A 004250, 1012A 004500, 1012A 0041000