Belden 1056A 4 paires 20 + 1/C 22 AWG blindé PLTC-ER Noir PVC gaine

SKU:Belden 1056A
$361.20
● En stock
Description
Belden câble d’instrumentation 1056A 010 comprend 4 paires #20 + 1/C 22 AWG toronné conducteurs et un gainenoir. Il est construit avec une isolation PVC et un blindage® Beldfoil global. Les marquages incluent PLTC-ER ITC-ER CMG AWM 2464 SUN RES.
Spécifications
| Attribute | Value |
|---|---|
| Conductor Type | Stranded Conductor |
| Pair insulation thickness (nominal) | 0.018 in (0.46 mm) |
| Pair insulation diameter (nominal) | 0.071 in (1.8 mm) |
| Pair color code | ICEA Chart E1 |
| Comm wire insulation thickness (nominal) | 0.019 in (0.48 mm) |
| Comm wire insulation diameter (nominal) | 0.066 in (1.7 mm) |
| Comm Wire color | Orange |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Outer jacket thickness (nominal) | 0.042 in (1.1 mm) |
| Overall cable diameter (nominal) | 0.405 in (10.3 mm) |
| Pair conductor DCR (nominal) | 10.9 Ohm/1000ft |
| Pair capacitance, Cond-to-Cond (nominal) | 30 pF/ft (98 pF/m) |
| Pair capacitance, Cond-to-Shield (nominal) | 55 pF/ft (180 pF/m) |
| Pair inductance (nominal) | 0.19 µH/ft (0.62 µH/m) |
| Pair max. current | 5.6 Amps per Conductor @ 30°C |
| Comm wire conductor DCR (nominal) | 17.2 Ohm/1000ft (56.4 Ohm/km) |
| Comm wire max. current | 9.6 Amps per Conductor @ 30°C |
| Nom. outer shield DCR | 7.71 Ohm/1000ft (25.3 Ohm/km) |
| Bend radius (stationary min.) | 4.9 in (120 mm) |
| Bend radius (installation min.) | 4.9 in (120 mm) |
| Max Pull Tension | 123 lbs (55.8 kg) |
| Bulk cable weight | 78 lbs/1000ft |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4 |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Thermocouple | No |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |
Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.
Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?
Notre équipe établit des devis pour les longueurs personnalisées et les commandes en gros, généralement le jour même.