Belden 1424A 060, Multi Conductor Computer Cable 12 Pair + 1 24 AWG

SKU:Belden 1424A 060
● En stock
Description
Belden 1424A 060 is a multi-pair computer communications cable for EIA RS-232/422 and RS-423 signal transmission, including extended distance applications. It is built with 12 twisted pairs + 1 Conductor using 24 AWG stranded (7x32) TC - Tinned Copper and Datalene® insulation. An overall Beldfoil® shield with 100% coverage and a 24 AWG (7x32) TC drainwire help reduce EMI, and the PVC - Polyvinyl Chloride jacket is rated CM for indoor use.
Key Features
- 12 pair(s) + 1 Conductor construction supports multi-pair signal transmission in one cable.
- 24 AWG stranded (7x32) TC - Tinned Copper conductors support low-voltage analog and digital control signals.
- Overall shield with 100% coverage plus drainwire helps reduce EMI.
- PVC - Polyvinyl Chloride jacket with CM rating supports indoor installations.
Technical Specs
Construction & Materials
| Number of elements | 12 pair(s) + 1 Conductor |
|---|---|
| Conductor size | 24 AWG |
| Conductor stranding | 7x32 |
| Conductor material | TC - Tinned Copper |
| Conductor type | Stranded Conductor |
| Insulation material | Datalene® |
| Pair(s) insulation | PE - Polyethylene (Foam) |
| Nom. insulation thickness | 0.0125 in (0.318 mm) |
| Nom. insulation diameter | 0.049 in (1.2 mm) |
| Pair color code | Western Electric Standard |
| Conductor(s) color | Gray |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield construction | Overall Shield & drain |
| Drainwire | 24 AWG (7x32) TC |
| Jacket material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.035 in (0.89 mm) |
Physical Dimensions & Weight
| Overall cable diameter (nominal) | 0.418 in (10.6 mm) |
|---|---|
| Bulk cable weight | 76 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. conductor DCR (pair(s)) | 24 Ohm/1000ft |
|---|---|
| Nom. capacitance Cond-to-Cond | 13 pF/ft (43 pF/m) |
| Nom. capacitance Cond-to-other (conds + Shield) | 22 pF/ft (72 pF/m) |
| Nom. characteristic impedence | 100 Ohm |
| Nom. inductance | 0.213 μH/ft (0.699 μH/m) |
| Nom. velocity of prop. | 78% |
| Max. current | 1.8 Amps per Conductor at 25ºC |
| Nom outer Shield DCR | 12 Ohm/1000ft (39 Ohm/km) |
Environmental & Mechanical Ratings
| UL voltage rating | 300 V (CM), 30 V (UL AWM 2919) |
|---|---|
| Operating temperature | -20°C to +80°C |
| UL temperature | 80°C |
| Bend radius (stationary min.) | 2.9 in (74 mm) |
| Bend radius (installation min.) | 2.9 in (74 mm) |
| Max. pull tension | 138 lbs (62.6 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
Compliance & Certifications
| NEC / UL compliance | Article 800, CM |
|---|---|
| CEC / C(UL) compliance | CM |
| AWM compliance | AWM 2919 |
| Flammability / reaction to fire | UL 1685 FT4 Loading |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Designed for RS-232 extended distance applications.
- Suitable for RS-423 applications.
- Used in computer communications signal transmission.
- Supports low voltage analog signals (4-20ma, 0-10v, ...).
- Supports low voltage digital control (24v, …).
- Used for line level audio signal runs.
- Commonly installed for panel wiring in indoor environments.
Belden™ and all associated trademarks are the property of their respective owners.
Spécifications
| Attribute | Value |
|---|---|
| Number of elements | 12 pair(s) + 1 Conductor |
| Conductor size | 24 AWG |
| Conductor stranding | 7x32 |
| Conductor Material | TC - Tinned Copper |
| Conductor Type | Stranded Conductor |
| Insulation Material | Datalene® |
| Pair(s) insulation | PE - Polyethylene (Foam) |
| Nom. insulation thickness | 0.0125 in (0.318 mm) |
| Nom. insulation diameter | 0.049 in (1.2 mm) |
| Pair color code | Western Electric Standard |
| Conductor(s) color | Gray |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield construction | Overall Shield & drain |
| Drain Wire | 24 AWG (7x32) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.035 in (0.89 mm) |
| Overall cable diameter (nominal) | 0.418 in (10.6 mm) |
| Bulk cable weight | 76 lbs/1000ft |
| Nom. Conductor DCR (pairs) | 24 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 13 pF/ft (43 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 22 pF/ft (72 pF/m) |
| Nom. characteristic impedence | 100 Ohm |
| Nom. inductance | 0.213 μH/ft (0.699 μH/m) |
| Nom. velocity of prop. | 78% |
| Max. current | 1.8 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 12 Ohm/1000ft (39 Ohm/km) |
| UL Voltage Rating | 300 V (CM), 30 V (UL AWM 2919) |
| Operating temperature | -20°C to +80°C |
| UL temperature | 80°C |
| Bend radius (stationary min.) | 2.9 in (74 mm) |
| Bend radius (installation min.) | 2.9 in (74 mm) |
| Max Pull Tension | 138 lbs (62.6 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| NEC / UL compliance | Article 800, CM |
| CEC / C(UL) compliance | CM |
| AWM compliance | AWM 2919 |
| Flammability / reaction to fire | UL 1685 FT4 Loading |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.
Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?
Notre équipe établit des devis pour les longueurs personnalisées et les commandes en gros, généralement le jour même.