Belden 1475A 4 paires 18 + 1/C 22 AWG SPOS PLTC-ER Noir PVC gaine

SKU:Belden 1475A
$546.00
● En stock
Description
Belden câble d’instrumentation 1475A 010 possède une gaine noire et une construction 4 paires #18 + 1/C 22 AWG toronné . Il propose PVC isolation avec des blindageindividuels et globaux. Les classifications et marquages incluent PLTC-ER ITC-ER CMG AWM 2464 SUN RES DIR BUR.
Applications
- À utiliser pour des installations d’instrumentation câble nécessitant PVC isolation et individuelle et globale blindage.
- Spécifiez où PLTCmarquages -ER, ITC-ER, CMG ou AWM 2464 sont requis.
- Choisissez des environnements qui nécessitent des marquages SUN RES et DIR BUR.
Spécifications
| Attribute | Value |
|---|---|
| Pairs | 4 |
| Pair Conductor Size | 18 AWG |
| Pair Stranding | 7x26 |
| Pair Conductor Material | BC - Bare Copper |
| Comm Wire(s) | 1 |
| Comm Wire size | 22 AWG |
| Comm Wire stranding | 7x30 |
| Comm Wire material | BC - Bare Copper |
| Conductor Type | Stranded conductor |
| Pair insulation material | PVC - Polyvinyl Chloride |
| Pair nominal insulation thickness | 0.017 in (0.43 mm) |
| Pair nominal Insulation Diameter | 0.080 in (2.0 mm) |
| Pair color code | ICEA Chart E1 |
| Comm wire insulation material | PVC - Polyvinyl Chloride |
| Comm wire nominal insulation thickness | 0.019 in (0.48 mm) |
| Comm wire nominal insulation diameter | 0.066 in (1.7 mm) |
| Comm Wire color | Orange |
| Shield configuration | Both individual and overall shields |
| Individual pair shield | Tape, Bi-Laminate (Alum+Poly), 100% coverage (each pair) |
| Individual pair drainwire | 20 AWG (7x28) TC |
| Overall shield | Tape, Bi-Laminate (Alum+Poly), 100% coverage |
| Overall drainwire | 18 AWG (7x26) TC |
| Shield | Yes - this has a shield |
| Jacket Color | Black |
| Jacket Material | PVC - Polyvinyl Chloride |
| Nominal jacket thickness | 0.053 in (1.3 mm) |
| Nominal diameter | 0.494 in (12.5 mm) |
| Overall cable diameter (nominal) | 0.494 in (12.5 mm) |
| Ripcord | Yes |
| Armor | No |
| Pair nominal Conductor DCR | 6.66 Ohm/1000ft |
| Pair nominal inner Shield DCR | 8.48 Ohm/1000ft (27.8 Ohm/km) |
| Pair max. current | 10 Amps per conductor @ 30°C |
| Comm Wire nominal Conductor DCR | 17.2 Ohm/1000ft (56.4 Ohm/km) |
| Comm wire max. current | 9.6 Amps per conductor @ 30°C |
| Nom. outer shield DCR | 4.8 Ohm/1000ft (16 Ohm/km) |
| Operating temperature | -30°C to +105°C |
| UL temperature | 105°C |
| Bend radius (stationary min.) | 5.9 in (150 mm) |
| Bend radius (installation min.) | 5.9 in (150 mm) |
| Max Pull Tension | 223 lbs (101 kg) |
| Bulk cable weight | 118 lbs/1000ft |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, T-29-520, IEEE 1202 FT4 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |
Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.
Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?
Notre équipe établit des devis pour les longueurs personnalisées et les commandes en gros, généralement le jour même.