Contact1-800-975-3686
Ramcorp Wire & Cable

Belden 1492A 2 paires 16 + 1/C 22 AWG SPOS PLTC-ER Noir PVC gaine

Belden 1492A 010

SKU:Belden 1492A

$493.20

En stock

Description

Spécifications

Belden 1492A 2 paires 16 + 1/C 22 AWG SPOS PLTC-ER Noir PVC gaine specifications
AttributeValue
Pairs2
Comm Wire(s)1
Conductor TypeStranded conductor
Pair Conductor Size16 AWG
Pair Stranding7x24
Pair Conductor MaterialBC - Bare Copper
Comm Wire size22 AWG
Comm Wire stranding7x30
Comm Wire materialBC - Bare Copper
Pair insulation materialPVC - Polyvinyl Chloride
Pair nominal insulation thickness0.019 in (0.48 mm)
Pair nominal Insulation Diameter0.095 in (2.4 mm)
Pair color codeICEA Chart E1
Comm wire insulation materialPVC - Polyvinyl Chloride
Comm wire nominal insulation thickness0.019 in (0.48 mm)
Comm wire nominal insulation diameter0.066 in (1.7 mm)
Comm Wire colorOrange
Inner shield (each pair)Tape, Bi-Laminate (Alum+Poly), 100%
Inner shield drainwire18 AWG (7x26) TC
Outer shieldTape, Bi-Laminate (Alum+Poly), 100%
Outer shield drainwire16 AWG (7x24) TC
Nominal jacket thickness0.053 in (1.3 mm)
Overall cable diameter (nominal)0.476 in (12.1 mm)
RipcordYes
ArmorNo
Pair nominal Conductor DCR4.2 Ohm/1000ft
Pair nominal inner Shield DCR5.58 Ohm/1000ft (18.3 Ohm/km)
Nom. outer shield DCR3.3 Ohm/1000ft (11 Ohm/km)
Pair nominal capacitance Cond-to-Cond60 pF/ft (200 pF/m)
Pair nominal capacitance Cond-to-other (Conds + Shield)110 pF/ft (360 pF/m)
Max. Current (pair(s))14 Amps per Conductor @ 30°C
Comm Wire nominal Conductor DCR17.2 Ohm/1000ft (56.4 Ohm/km)
Max. current (comm wire)9.6 Amps per Conductor @ 30°C
Operating temperature-30°C to +105°C
UL temperature105°C
Bend radius (stationary min.)5.7 in (140 mm)
Bend radius (installation min.)5.7 in (140 mm)
Max Pull Tension210 lbs (95 kg)
Bulk cable weight115 lbs/1000ft
Environmental suitabilityIndoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial
NEC / UL complianceArticle 725, Article 727, Article 800, CMG, ITC, PLTC
AWM complianceAWM 2464
CEC / C(UL) complianceCMG
Flammability / reaction to fireUL 1685 FT4 Loading, FT4, IEEE 1202 FT4
Ratings & MarkingsPLTC ITC CMG AWM 2464 SUN RES
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC complianceChina RoHS II (GB/T 26572-2011)
UL instrumentationUL instrumentation
Priced PerFT
Item TypeBelden Instrumentation Cable

Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.

Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?

Notre équipe établit des devis pour les longueurs personnalisées et les commandes en gros, généralement le jour même.