Belden 1530A 010, Coax CATV Cable 18 AWG FR PVC Black

SKU:Belden 1530A 010
● En stock
Description
Belden 1530A 010 is a Series 6 (RG 6) CATV coaxial cable with 75 Ohm nominal characteristic impedance for indoor general-purpose installations. It features an 18 AWG solid BCCS - Bare Copper Covered Steel conductor and PE - Polyethylene (Foam) insulation with Gas Injected construction. Shielding includes Tape, Tri-Laminate (Alum+Poly+Alum), Duoofoil®, 100% plus an Aluminum braid at 90% coverage. A black PVC - Polyvinyl Chloride jacket and NEC/(UL) compliance: CATV, CM support standard indoor routing requirements.
Belden 1530A 010 Key Features
- Series 6 (RG 6) coaxial construction with 1 coax and 1 conductor.
- 75 Ohm nominal characteristic impedance for CATV signal transmission.
- 18 AWG solid BCCS - Bare Copper Covered Steel conductor with 0.04 in nominal diameter.
- PE - Polyethylene (Foam) insulation with Gas Injected construction and 0.18 in nominal diameter.
- Dual-layer shielding: Tape, Tri-Laminate (Alum+Poly+Alum), Duoofoil®, 100% plus braid, Aluminum, 90%.
- Black PVC - Polyvinyl Chloride jacket with 0.27 in nominal diameter.
- NEC/(UL) compliance: CATV, CM; CEC/C(UL) compliance: CM; CPR Euroclass: Eca.
- UL voltage rating: 350 V RMS.
- Operating temperature range: -40°C to +80°C; UL temperature rating: 80°C.
Belden 1530A 010 Technical Specs
Performance & Electrical Characteristics
| Nominal capacitance (Conductor to Shield) | 16.2 pF/ft |
|---|---|
| Nominal inductance | 0.097 μH/ft |
| Nominal delay | 1.2 ns/ft |
| Nominal velocity of propagation (VP) | 83% |
| Return loss | 5 - 1000 MHz, 20 dB (min. structural return loss (SRL)) |
| Nominal Conductor DCR | 28 Ohm/1000ft |
| Nominal outer Shield DCR | 5 Ohm/1000ft |
| Outer Conductor DCR | 5 Ohm/1000ft |
Max. Insertion Loss (Attenuation)
| Max. insertion loss (attenuation) | 5 MHz, 0.58 dB/100ft |
|---|---|
| Max. insertion loss (attenuation) | 55 MHz, 1.60 dB/100ft |
| Max. insertion loss (attenuation) | 211 MHz, 3.05 dB/100ft |
| Max. insertion loss (attenuation) | 270 MHz, 3.37 dB/100ft |
| Max. insertion loss (attenuation) | 300 MHz, 3.55 dB/100ft |
| Max. insertion loss (attenuation) | 350 MHz, 3.85 dB/100ft |
| Max. insertion loss (attenuation) | 400 MHz, 4.15 dB/100ft |
| Max. insertion loss (attenuation) | 450 MHz, 4.40 dB/100ft |
| Max. insertion loss (attenuation) | 550 MHz, 4.90 dB/100ft |
| Max. insertion loss (attenuation) | 750 MHz, 5.65 dB/100ft |
| Max. insertion loss (attenuation) | 870 MHz, 6.11 dB/100ft |
| Max. insertion loss (attenuation) | 1000 MHz, 6.55 dB/100ft |
Physical & Mechanical Ratings
| Bulk Cable Weight | 28 lbs/1000ft |
|---|---|
| Maximum recommended pulling tension | 162 lbs |
| Minimum minor axis Bend Radius | 2.75 in |
Environmental & Installation
| UL flammability | UL1685 UL Loading |
|---|---|
| Environmental space | Indoor (Not Riser or Plenum) |
| Suitability - indoor | Yes |
| Plenum (Y/N) | No |
| Plenum number | 1530AP |
Compliance & Directives
| EU Directive 2000/53/EC (ELV) | Yes |
|---|---|
| EU Directive 2003/96/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| EU CE Mark | No |
| MII Order #39 (China RoHS) | Yes |
Belden 1530A 010 Applications
- Use it for indoor general-purpose installations where CATV coaxial cabling is required.
- Install it in Indoor (Not Riser or Plenum) environments, with Plenum (Y/N): No.
- Meet CATV and CM compliant installation contexts per NEC/(UL) compliance: CATV, CM and CEC/C(UL) compliance: CM.
Belden™ and all associated trademarks are the property of their respective owners.
Spécifications
| Attribute | Value |
|---|---|
| Nominal capacitance (conductor-to-shield) | 16.2 pF/ft |
| Nominal inductance | 0.097 µH/ft |
| Nominal delay | 1.2 ns/ft |
| Nominal velocity of propagation (VP) [%] | 83% |
| Return loss | 5 - 1000 MHz, 20 dB (min. structural return loss (SRL)) |
| Nominal conductor DCR | 28 Ohm/1000ft |
| Nominal outer shield DCR | 5 Ohm/1000ft |
| Outer conductor DCR | 5 Ohm/1000ft |
| Max. insertion loss (attenuation) | 5 MHz, 0.58 dB/100ft; 55 MHz, 1.60 dB/100ft; 211 MHz, 3.05 dB/100ft; 270 MHz, 3.37 dB/100ft; 300 MHz, 3.55 dB/100ft; 350 MHz, 3.85 dB/100ft; 400 MHz, 4.15 dB/100ft; 450 MHz, 4.40 dB/100ft; 550 MHz, 4.90 dB/100ft; 750 MHz, 5.65 dB/100ft; 870 MHz, 6.11 dB/100ft; 1000 MHz, 6.55 dB/100ft |
| Bulk cable weight | 28 lbs/1000ft |
| Maximum recommended pulling tension | 162 lbs |
| Minimum minor axis bend radius | 2.75 in |
| UL flammability | UL1685 UL Loading |
| Environmental space | Indoor (Not Riser or Plenum) |
| Suitability - indoor | Yes |
| Plenum (Y/N) | No |
| Plenum number | 1530AP |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/96/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU directive compliance | EU Directive 2003/11/EC (BFR) |
| EU CE mark | No |
| MII Order #39 (China RoHS) | Yes |
| Priced Per | FT |
Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.
Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?
Notre équipe établit des devis pour les longueurs personnalisées et les commandes en gros, généralement le jour même.