Belden 1694A 007, RG6 18 Solid BC Duofoil+95% PVC Jacket CMR ROHS, Violet Jacket

SKU:Belden 1694A 007
● En stock
Description
Belden 1694A 007 is a 75 Ohm SDI coax in the RG-6 format designed for digital video transmission, including 6 Gb/s UHDTV and HD-SDI 1080p. It features an 18 AWG solid BC - Bare Copper conductor with PE - Polyethylene (Foam) insulation. Shielding is provided by Duofoil® tri-laminate tape plus a 95% Tinned Copper braid, and the cable is finished with a PVC - Polyvinyl Chloride jacket in Violet. It carries a CMR rating and a 300 V (CMR, CMG) UL Voltage Rating.
Belden 1694A 007 Key Features
- 75 Ohm characteristic impedance for SDI coax applications.
- RG-6 coax construction with an 18 AWG solid BC - Bare Copper conductor.
- PE - Polyethylene (Foam) insulation with White color code.
- Shielding includes Duofoil® tri-laminate tape (100% coverage) plus a Tinned Copper (TC) braid (95% coverage).
- PVC - Polyvinyl Chloride jacket in Violet with CMR and CMG compliance and a 300 V (CMR, CMG) UL Voltage Rating.
Belden 1694A 007 Technical Specs
Construction & Physical Specs
| Coax construction | Coaxial |
|---|---|
| Coax type | RG-6 |
| RG type | 6 |
| Overall cable diameter (nominal) | 0.274 in (6.96 mm) |
| Conductor nom. diameter | 0.040 in |
| Nom. insulation diameter | 0.180 in (4.57 mm) |
| Shield type | Both, braid over foil |
| Flooded | No not flooded over braid |
| Jacket nom. diameter | 0.274 in (6.96 mm) |
| Outdoor | No not outdoor grade material |
| Bulk cable weight | 41 lbs/1000ft (61 kg/km) |
| Plenum number | 1695A |
Electrical Characteristics
| Nom. conductor DCR | 6.4 Ohm/1000ft (21 Ohm/km) |
|---|---|
| Nom. outer shield DCR | 3.8 Ohm/1000ft (12 Ohm/km) |
| Nom. capacitance cond-to-shield | 16.2 pF/ft (53.1 pF/m) |
| Nom. velocity of prop. | 82% |
Return Loss
| Return loss 5 - 1600 MHz | 23 dB |
|---|---|
| Return loss 1600 - 4500 MHz | 21 dB |
| Return loss 4500 - 6000 MHz | 15 dB |
Attenuation (Nominal)
| Attenuation (nominal) 1 MHz | 0.24 dB/100ft |
|---|---|
| Attenuation (nominal) 3.58 MHz | 0.44 dB/100ft |
| Attenuation (nominal) 5 MHz | 0.52 dB/100ft |
| Attenuation (nominal) 6 MHz | 0.57 dB/100ft |
| Attenuation (nominal) 7 MHz | 0.61 dB/100ft |
| Attenuation (nominal) 10 MHz | 0.71 dB/100ft |
| Attenuation (nominal) 12 MHz | 0.78 dB/100ft |
| Attenuation (nominal) 25 MHz | 1.08 dB/100ft |
| Attenuation (nominal) 67.5 MHz | 1.65 dB/100ft |
| Attenuation (nominal) 71.5 MHz | 1.69 dB/100ft |
| Attenuation (nominal) 88.5 MHz | 1.86 dB/100ft |
| Attenuation (nominal) 100 MHz | 1.95 dB/100ft |
| Attenuation (nominal) 135 MHz | 2.24 dB/100ft |
| Attenuation (nominal) 143 MHz | 2.3 dB/100ft |
| Attenuation (nominal) 180 MHz | 2.57 dB/100ft |
| Attenuation (nominal) 270 MHz | 3.17 dB/100ft |
| Attenuation (nominal) 360 MHz | 3.69 dB/100ft |
| Attenuation (nominal) 540 MHz | 4.5 dB/100ft |
| Attenuation (nominal) 720 MHz | 5.3 dB/100ft |
| Attenuation (nominal) 750 MHz | 5.4 dB/100ft |
| Attenuation (nominal) 1000 MHz | 6.3 dB/100ft |
| Attenuation (nominal) 1500 MHz | 7.8 dB/100ft |
| Attenuation (nominal) 2000 MHz | 9.2 dB/100ft |
| Attenuation (nominal) 2250 MHz | 9.8 dB/100ft |
| Attenuation (nominal) 3000 MHz | 11.5 dB/100ft |
| Attenuation (nominal) 4500 MHz | 14.5 dB/100ft |
| Attenuation (nominal) 6000 MHz | 17.7 dB/100ft |
Environmental & Mechanical Ratings
| UL temperature | 60°C |
|---|---|
| Operating temperature | -30°C to +75°C |
| Installation min. bend radius | 2.75 in (69.9 mm) |
| Max. pull tension | 69 lbs (31 kg) |
| Fire rating | Riser |
| Flammability / reaction to fire | UL1666 Vertical Shaft |
| Environmental suitability | Indoor/Outdoor, Indoor, UV Resistance, Aerial - Black only, When supported by messenger Wire |
Compliance & Certifications
| NEC / UL compliance | CMR |
|---|---|
| CEC / C(UL) compliance | CMG |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
Belden 1694A 007 Applications
- Use it for digital video signal transmission.
- Support 6 Gb/s UHDTV distribution where consistent digital video performance is required.
- Deploy it for HD-SDI 1080p video links in professional video systems.
Belden™ and all associated trademarks are the property of their respective owners.
Spécifications
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| Coax Type | RG-6 |
| RG type | 6 |
| Overall cable diameter (nominal) | 0.274 in (6.96 mm) |
| Conductor nom. diameter | 0.040 in |
| Nom. insulation diameter | 0.180 in (4.57 mm) |
| Shield Type | Both, braid over foil |
| Flooded | No not flooded over braid |
| Jacket nom. diameter | 0.274 in (6.96 mm) |
| Outdoor | No not outdoor grade material |
| Bulk cable weight | 41 lbs/1000ft (61 kg/km) |
| Plenum number | 1695A |
| Nom. conductor DCR | 6.4 Ohm/1000ft (21 Ohm/km) |
| Nom. outer shield DCR | 3.8 Ohm/1000ft (12 Ohm/km) |
| Nom. capacitance (Cond-to-Shield) | 16.2 pF/ft (53.1 pF/m) |
| Nom. velocity of prop. | 82% |
| Return loss (5 - 1600 MHz) | 23 dB |
| Return loss (1600 - 4500 MHz) | 21 dB |
| Return loss (4500 - 6000 MHz) | 15 dB |
| Attenuation (nominal) 1 MHz | 0.24 dB/100ft |
| Attenuation (Nominal) 3.58 MHz | 0.44 dB/100ft |
| Attenuation (Nominal) 5 MHz | 0.52 dB/100ft |
| Attenuation (Nominal) 6 MHz | 0.57 dB/100ft |
| Attenuation (Nominal) 7 MHz | 0.61 dB/100ft |
| Attenuation (nominal) 10 MHz | 0.71 dB/100ft |
| Attenuation (Nominal) 12 MHz | 0.78 dB/100ft |
| Attenuation (Nominal) 25 MHz | 1.08 dB/100ft |
| Attenuation (Nominal) 67.5 MHz | 1.65 dB/100ft |
| Attenuation (Nominal) 71.5 MHz | 1.69 dB/100ft |
| Attenuation (Nominal) 88.5 MHz | 1.86 dB/100ft |
| Attenuation (nominal) 100 MHz | 1.95 dB/100ft |
| Attenuation (Nominal) 135 MHz | 2.24 dB/100ft |
| Attenuation (Nominal) 143 MHz | 2.3 dB/100ft |
| Attenuation (Nominal) 180 MHz | 2.57 dB/100ft |
| Attenuation (Nominal) 270 MHz | 3.17 dB/100ft |
| Attenuation (Nominal) 360 MHz | 3.69 dB/100ft |
| Attenuation (Nominal) 540 MHz | 4.5 dB/100ft |
| Attenuation (Nominal) 720 MHz | 5.3 dB/100ft |
| Attenuation (Nominal) 750 MHz | 5.4 dB/100ft |
| Attenuation (nominal) 1000 MHz | 6.3 dB/100ft |
| Attenuation (Nominal) 1500 MHz | 7.8 dB/100ft |
| Attenuation (Nominal) 2000 MHz | 9.2 dB/100ft |
| Attenuation (Nominal) 2250 MHz | 9.8 dB/100ft |
| Attenuation (Nominal) @ 3000 MHz | 11.5 dB/100ft |
| Attenuation (Nominal) 4500 MHz | 14.5 dB/100ft |
| Attenuation (Nominal) 6000 MHz | 17.7 dB/100ft |
| UL temperature | 60°C |
| Operating temperature | -30°C to +75°C |
| Installation min. bend radius | 2.75 in (69.9 mm) |
| Max Pull Tension | 69 lbs (31 kg) |
| Fire rating | Riser |
| Flammability / reaction to fire | UL1666 Vertical Shaft |
| Environmental suitability | Indoor/Outdoor, Indoor, UV Resistance, Aerial - Black only, When supported by messenger Wire |
| NEC / UL compliance | CMR |
| CEC / C(UL) compliance | CMG |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Priced Per | FT |