Belden 27325AS, Multi Conductor Type TC Cable 2C 18 AWG 600V PVC

SKU:Belden 27325AS
● En stock
Description
Belden 27325AS is a UL Type TC (1277) multi conductor control cable for power and control applications up to 600V, including Class 1 Division 2 hazardous locations. It features 2 stranded 18 AWG (7x26) BC - Bare Copper conductors with PVC-Nylon/PVC insulation and an overall Beldfoil® shield for noise protection. The cable has a black PVC outer jacket with ripcord and is rated 90°C dry and 90°C wet for wet/dry environments. It is listed for indoor/outdoor use with sunlight resistance and burial capability, with a recommended cable gland of Belden BTC075A0551RA.
Belden 27325AS Key Features
- UL Type TC (1277) multi conductor control cable for power and control applications up to 600V, including Class 1 Division 2 hazardous locations.
- 2 stranded 18 AWG (7x26) BC - Bare Copper conductors.
- Overall Beldfoil® shield (tape) with 100% coverage for noise protection.
- Black PVC outer jacket with ripcord for easier installation.
- UL temperature rating of 90°C dry and 90°C wet for wet/dry environments.
- Environmental suitability: indoor, outdoor, sunlight resistance, burial.
- Recommended cable gland: Belden BTC075A0551RA.
Belden 27325AS Technical Specs
Construction & Materials
| Conductor count | 2 |
|---|---|
| Conductor size | 18 AWG |
| Stranding | 7x26 |
| Conductor material | BC - Bare Copper |
| Insulation material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Color code | Black, Red |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drainwire type | 20 AWG (7x28) TC |
| Jacket material | PVC - Polyvinyl Chloride |
| Ripcord | Yes |
Dimensions & Weight
| Nom. thickness | 0.022 in (0.56 mm) |
|---|---|
| Nom. insulation diameter | 0.088 in (2.2 mm) |
| Nom. jacket thickness | 0.048 in (1.2 mm) |
| Overall cable diameter (nominal) | 0.276 in (7.01 mm) |
| Bulk cable weight | 33 lbs/1000ft |
Electrical Characteristics
| UL voltage rating | 600 V (TC), 150 V (NPLF) |
|---|---|
| Nom. conductor DCR | 6.7 Ohm/1000ft |
| Nom outer shield DCR | 10.39 Ohm/1000ft (34.09 Ohm/km) |
| Max. current | 14 Amps per Conductor at 30ºC |
Environmental & Mechanical Ratings
| Operating | Wet/Dry: -30°C to 90°C |
|---|---|
| Bend radius (stationary min.) | 3.312 in (84.12 mm) |
| Bend radius (installation min.) | 3.312 in (84.12 mm) |
| Max. pull tension | 53 lbs (24 kg) |
Compliance & Certifications
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
|---|---|
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 336, Article 400, Article 760, NPLF, TC, TFFN |
| European directive compliance | EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
Belden 27325AS Applications
- Use it for power and control applications up to 600V.
- Specify it for Class 1 Division 2 hazardous locations.
- Pair it with the recommended cable gland Belden BTC075A0551RA.
Belden™ and all associated trademarks are the property of their respective owners.
Spécifications
| Attribute | Value |
|---|---|
| Conductor count | 2 |
| Conductor size | 18 AWG |
| Stranding | 7x26 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Color Code | Black, Red |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drainwire type | 20 AWG (7x28) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Ripcord | Yes |
| Nom. thickness | 0.022 in (0.56 mm) |
| Nom. insulation diameter | 0.088 in (2.2 mm) |
| Nom. jacket thickness | 0.048 in (1.2 mm) |
| Overall cable diameter (nominal) | 0.276 in (7.01 mm) |
| Bulk cable weight | 33 lbs/1000ft |
| UL Voltage Rating | 600 V (TC), 150 V (NPLF) |
| Nom. conductor DCR | 6.7 Ohm/1000ft |
| Nom. outer shield DCR | 10.39 Ohm/1000ft (34.09 Ohm/km) |
| Max. current | 14 Amps per Conductor at 30ºC |
| Operating | Wet/Dry: -30°C to 90°C |
| Bend radius (stationary min.) | 3.312 in (84.12 mm) |
| Bend radius (installation min.) | 3.312 in (84.12 mm) |
| Max Pull Tension | 53 lbs (24 kg) |
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 336, Article 400, Article 760, NPLF, TC, TFFN |
| European directive compliance | EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| Priced Per | FT |