Belden 28110AS 010, 12 3C Stranded BC THWN 2 Foil Shield PVC 600V, Black Jacket

SKU:Belden 28110AS 010
● En stock
Description
Belden 28110AS 010 is a VNTC control cable for power and control applications up to 600V. It features 3 stranded 12 AWG BC - Bare Copper conductors with PVC/Nylon - Polyvinyl Chloride + Nylon insulation and an overall Beldfoil® Shield to help reduce electrical noise. The cable has a black PVC - Polyvinyl Chloride outer jacket and is rated 600 V (TC-ER) and 150 V (NPLF) with 90°C Dry, 90°C Wet performance. It is suitable for indoor, outdoor, sunlight resistance, UV resistance, burial and meets NEC / UL compliance: Article 336, Article 310, Article 760, NPLF, TC-ER, THWN-2.
Belden 28110AS 010 Key Features
- 3 stranded 12 AWG BC - Bare Copper conductors for power and control applications up to 600V.
- PVC/Nylon - Polyvinyl Chloride + Nylon insulation with UL type: TC (1277) PVC-Nylon/PVC.
- Overall Beldfoil® Shield (tape) with 100% coverage and Shield Material: Bi-Laminate (Alum+Poly).
- UL Voltage Rating: 600 V (TC-ER), 150 V (NPLF).
- UL temperature: 90°C Dry, 90°C Wet.
- Environmental suitability: indoor, outdoor, sunlight resistance, UV resistance, burial.
- NEC / UL compliance: Article 336, Article 310, Article 760, NPLF, TC-ER, THWN-2.
Belden 28110AS 010 Technical Specs
Construction & Materials
| Conductor stranding | 7x20 |
|---|---|
| Conductor type | Stranded |
| Earth/ground wires | No |
| Insulation thickness (nom.) | 0.019 in (0.48 mm) |
| Insulation diameter (nom.) | 0.131 in (3.33 mm) |
| Color code | Black, Red, Blue |
| Shielded | Yes |
| Shield type | Tape |
| Drainwire type | 12 AWG (7x20) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket color | Black |
| Ripcord | Yes |
| Armor | No |
| Composite | No |
Dimensions & Weight
| Jacket thickness (nom.) | 0.047 in (1.2 mm) |
|---|---|
| Overall cable diameter (nom.) | 0.378 in |
| Bulk cable weight | 126 lbs/1000ft |
Electrical Characteristics
| Nom. Conductor DCR | 1.68 Ohm/1000ft |
|---|---|
| Max. current | 30 Amps per Conductor at 30ºC |
| Nom outer Shield DCR | 1.5 Ohm/1000ft (4.9 Ohm/km) |
Environmental & Mechanical Ratings
| Operating (Wet/Dry) | -30°C to 90°C |
|---|---|
| Bend radius (stationary min.) | 4.536 in (115.2 mm) |
| Bend radius (installation min.) | 4.536 in |
| Max. pull tension | 347.2 lbs (157.5 kg) |
Compliance & Certifications
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202 FT4 |
|---|---|
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
Belden 28110AS 010 Applications
- Use in power and control applications up to 600V.
- Choose for installations where electrical noise reduction is needed.
- Install in indoor or outdoor environments, including sunlight resistance and UV resistance exposure.
- Specify for installations that require burial suitability.
Belden™ and all associated trademarks are the property of their respective owners.
Spécifications
| Attribute | Value |
|---|---|
| Conductor stranding | 7x20 |
| Conductor Type | Stranded |
| Earth/ground wires | No |
| Insulation thickness (nom.) | 0.019 in (0.48 mm) |
| Insulation diameter (nom.) | 0.131 in (3.33 mm) |
| Color Code | Black, Red, Blue |
| Shielded | Yes |
| Shield Type | Tape |
| Drainwire type | 12 AWG (7x20) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Ripcord | Yes |
| Armor | No |
| Composite | No |
| Jacket thickness (nom.) | 0.047 in (1.2 mm) |
| Overall cable diameter (nom.) | 0.378 in |
| Bulk cable weight | 126 lbs/1000ft |
| Nom. conductor DCR | 1.68 Ohm/1000ft |
| Max. current | 30 Amps per Conductor at 30ºC |
| Nom. outer shield DCR | 1.5 Ohm/1000ft (4.9 Ohm/km) |
| Operating (wet/dry) | -30°C to 90°C |
| Bend radius (stationary min.) | 4.536 in (115.2 mm) |
| Bend radius (installation min.) | 4.536 in |
| Max Pull Tension | 347.2 lbs (157.5 kg) |
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202 FT4 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Priced Per | FT |
Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.
Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?
Notre équipe établit des devis pour les longueurs personnalisées et les commandes en gros, généralement le jour même.