Belden 28329AS 010, Control Cable 18 AWG 12C Foil Shield 600V PVC NYL, Black Jacket

SKU:Belden 28329AS 010
● En stock
Description
Belden 28329AS 010 is a 12 conductor 18 AWG control cable for power and control applications up to 600V. It features PVC/Nylon insulation with E2 color coding and an overall Beldfoil® tape shield with 100% coverage. Built to UL Type TC (1277) PVC-Nylon/PVC, it is rated 600 V (TC-ER) and 150 V (NPLF), with 90°C Dry and 90°C Wet temperature performance. A black PVC outer jacket with ripcord supports easier stripping and is listed for Indoor, Outdoor, Sunlight Resistance, and Burial environments.
Belden 28329AS 010 Key Features
- 12 conductor 18 AWG stranded construction with 7x26 stranding and BC - Bare Copper conductor material.
- PVC/Nylon - Polyvinyl Chloride + Nylon insulation with E2 color coding for conductor identification.
- Overall Beldfoil® shield tape design with Bi-Laminate (Alum+Poly) material and 100% coverage.
- UL voltage rating: 600 V (TC-ER), 150 V (NPLF).
- UL temperature: 90°C Dry, 90°C Wet; operating: Wet/Dry: -30°C to 90°C.
- Black PVC - Polyvinyl Chloride outer jacket with ripcord: Yes.
- UL type: UL Type TC (1277) PVC-Nylon/PVC.
Belden 28329AS 010 Technical Specs
Construction & Materials
| Product type | VNTC CONTROL |
|---|---|
| Conductor type | Stranded |
| Earth/ground wires | No |
| Insulation nominal thickness | 0.020 in (0.51 mm) |
| Insulation nominal diameter | 0.087 in (2.2 mm) |
| Color code | Black, Red, Blue, Orange, Yellow, Brown, Red/Black, Blue/Black, Orange/Black, Yellow/Black, Brown/Black, Black/Red |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 18 AWG (7x26) TC |
| Armor | No |
| Composite | No |
Electrical Characteristics
| Nom outer Shield DCR | 4.57 Ohm/1000ft (15.0 Ohm/km) |
|---|---|
| Nom. Conductor DCR | 6.7 Ohm/1000ft |
| Max. current | 24 Amps per Conductor at 30ºC |
Dimensions & Mechanical Specs
| Jacket nominal thickness | 0.047 in (1.2 mm) |
|---|---|
| Nominal diameter | 0.459 in (11.7 mm) |
| Overall cable diameter (nominal) | 0.459 in (11.7 mm) |
| Bend radius (stationary min.) | 5.508 in (139.9 mm) |
| Bend radius (installation min.) | 5.508 in (139.9 mm) |
| Max. pull tension | 284 lbs (129 kg) |
| Bulk cable weight | 141 lbs/1000ft |
Compliance, Flammability & Environmental
| NEC / UL compliance | Article 336, Article 400, Article 760, TC-ER, NPLF, TFFN |
|---|---|
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
Belden 28329AS 010 Applications
- Use it for power and control applications up to 600V where a control cable is required.
- Install it in Indoor and Outdoor environments when the application calls for Sunlight Resistance.
- Select it for burial environments when the installation specifies Burial suitability.
Belden™ and all associated trademarks are the property of their respective owners.
Spécifications
| Attribute | Value |
|---|---|
| Product type | VNTC CONTROL |
| Conductor Type | Stranded |
| Earth/ground wires | No |
| Insulation nominal thickness | 0.020 in (0.51 mm) |
| Insulation nominal diameter | 0.087 in (2.2 mm) |
| Color Code | Black, Red, Blue, Orange, Yellow, Brown, Red/Black, Blue/Black, Orange/Black, Yellow/Black, Brown/Black, Black/Red |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 18 AWG (7x26) TC |
| Armor | No |
| Composite | No |
| Nom. outer shield DCR | 4.57 Ohm/1000ft (15.0 Ohm/km) |
| Nom. conductor DCR | 6.7 Ohm/1000ft |
| Max. current | 24 Amps per Conductor at 30ºC |
| Jacket nominal thickness | 0.047 in (1.2 mm) |
| Nominal diameter | 0.459 in (11.7 mm) |
| Overall cable diameter (nominal) | 0.459 in (11.7 mm) |
| Bend radius (stationary min.) | 5.508 in (139.9 mm) |
| Bend radius (installation min.) | 5.508 in (139.9 mm) |
| Max Pull Tension | 284 lbs (129 kg) |
| Bulk cable weight | 141 lbs/1000ft |
| NEC / UL compliance | Article 336, Article 400, Article 760, TC-ER, NPLF, TFFN |
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Priced Per | FT |
Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.
Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?
Notre équipe établit des devis pour les longueurs personnalisées et les commandes en gros, généralement le jour même.