Contact1-800-975-3686
Ramcorp Wire & Cable

Belden 29501 010, Câble VFD, 3-14 AWG TC + 1G TC, Isolation XLPE, Blindé, Gaine PVC noire

Belden 29501

SKU:Belden 29501 010

$625.20

En stock

Description

Spécifications

Belden 29501 010, Câble VFD, 3-14 AWG TC + 1G TC, Isolation XLPE, Blindé, Gaine PVC noire specifications
AttributeValue
Conductor TypeStranded
Earth/ground wiresYes
Phase insulationXLPE - Cross-Linked Polyethylene (Thermoset)
Phase insulation thickness (nominal)0.046 in (1.2 mm)
Phase insulation diameter (nominal)0.173 in (4.39 mm)
Phase color codeICEA Chart M4
Insulated ground insulationPVC - Polyvinyl Chloride
Insulated ground thickness (nominal)0.047 in (1.2 mm)
Insulated ground insulation diameter (nominal)0.169 in (4.29 mm)
Insulated ground colorGreen/Yellow Stripe
Tape shield materialTri-Laminate (Alum+Poly+Alum)
Outer jacket materialPVC - Polyvinyl Chloride
Jacket ColorBlack
Jacket thickness (nominal)0.073 in (1.9 mm)
Overall cable diameter (nominal)0.604 in (15.3 mm)
RipcordYes
Nom. outer shield DCR1.08 Ohm/1000ft (3.54 Ohm/km)
Phase conductor DCR2.482 Ohm/1000ft
Insulated ground DCR2.73 Ohm/1000ft (8.96 Ohm/km)
Uninsulated ground wire DCR2.73 Ohm/1000ft (8.96 Ohm/km)
Capacitance (Cond-to-Cond)23.0 pF/ft (75.5 pF/m)
Capacitance (Cond-to-other)47 pF/ft (150 pF/m)
Characteristic impedence (nominal)63 Ohm
Inductance Cond-grnd (nominal)0.213 µH/ft
Inductance (nominal)0.213 µH/ft (0.699 µH/m)
Velocity of prop. (nominal)55%
Max. current25 Amps per conductor at 30ºC (per NEC)
Installation temperature-40C
Bend radius (stationary min.)7.2 in (180 mm)
Bend radius (installation min.)7.2 in (180 mm)
Max Pull Tension347 lbs (157 kg)
Bulk cable weight224 lbs/1000ft
Oil ResistantOil Resistant
Flammability / reaction to fireUL 1685 FT4 Loading, FT4, IEEE 1202 FT4
NEC / UL complianceArticle 336, TC-ER, XHHW-2, RHW-2, UL Flexible Motor Supply Cable
AWM complianceAWM I/II A/B
CEC / C(UL) complianceCIC, TC
ICEA complianceS-95-658
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC complianceChina RoHS II (GB/T 26572-2011)
Other standard compliance(s)P-07-KA070003-MSHA
SustainabilityCA Prop 65
Other Part Numbers29501 010, 29501 010100, 29501 010250, 29501 010500, 29501 0101000
Priced PerFT

Documents

Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.

Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?

Notre équipe établit des devis pour les longueurs personnalisées et les commandes en gros, généralement le jour même.