Belden 29525C, 3C6 VFD Cable 600V Black

SKU:Belden 29525C
● En stock
Description
Belden 29525C is a Belden Basics VFD cable for Variable Frequency Drives (VFD), AC motor and drive systems, and Class 1 Division 2 locations. It is built with 3 x 6 AWG BC - Bare Copper conductors, XLPE - Cross Linked Polyethylene insulation, and an overall dual copper tape helically applied shield with 100% coverage. The black PVC - Polyvinyl Chloride jacket includes a ripcord and is listed for Indoor, Outdoor, Sunlight Resistance, and Burial environments. Electrical performance includes 600/1000V construction, a UL Voltage Rating of 1000 V (TC-ER), and UL temperature ratings of 90°C Dry, 90°C Wet.
Belden 29525C Key Features
- Supports 600/1000V construction with a UL Voltage Rating of 1000 V (TC-ER).
- Uses 3 x 6 AWG BC - Bare Copper circuit conductors with XLPE - Cross Linked Polyethylene insulation.
- Includes a 6AWG symmetrical segmented ground (3 x 12 AWG) in continuous contact with an overall dual copper tape helically applied shield.
- Provides 100% shield coverage using BC helical tape.
- Finished with a black PVC - Polyvinyl Chloride outer jacket with ripcord for Indoor, Outdoor, Sunlight Resistance, and Burial suitability.
- Meets UL temperature ratings of 90°C Dry, 90°C Wet.
Belden 29525C Technical Specs
Construction & Materials
| Number of conductors | 3 |
|---|---|
| Conductor size | 6 AWG |
| Conductor stranding | 7x14 |
| Conductor notes | ASTM B3 Copper B8 Class B Stranding |
| Segmented ground wire | 3 x 12 AWG |
| Ground stranding | 7x20 |
| Ground notes | Segmented Grounds (3 Totaling 6AWG) |
| Insulation thickness (Nom.) | 0.047 in (1.2 mm) |
| Insulation diameter (Nom.) | 0.272 in (6.91 mm) |
| Color code | ICEA Chart M4 |
| Ground wire | No Insulation |
| Shield type | Helical Tape |
| Jacket thickness (Nom.) | 0.063 in (1.6 mm) |
| Overall cable diameter (Nominal) | 0.724 in (18.4 mm) |
Performance & Electrical Characteristics
| Nom. conductor DCR | 0.355 Ohm/1000ft (1.16 Ohm/km) |
|---|---|
| Nom. capacitance cond-to-cond | 32 pF/ft (100 pF/m) |
| Nom. capacitance cond-to-other (Conds + Shield) | 63 pF/ft (210 pF/m) |
| Nom. characteristic impedence | 37 Ohm |
| Nom. velocity of prop. | 55% |
| Max. current | 75 Amps per Conductor at 30ºC |
| Nom outer shield DCR | 2.72 Ohm/1000ft (8.92 Ohm/km) |
Environmental & Mechanical Ratings
| Operating | -40°C To +90°C |
|---|---|
| Stationary min. bend radius | 8.7 in (220 mm) |
| Installation min. bend radius | 8.7 in (220 mm) |
| Max. pull tension | 1304.1 lbs (591.53 kg) |
| Bulk cable weight | 461 lbs/1000ft (686 kg/km) |
| Environmental marking | SUN RES DIR BUR |
| Oil resistant | Oil Resistant |
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202 FT4, FT4 |
Compliance & Certifications
| NEC / UL compliance | Article 336, TC-ER, XHHW-2 |
|---|---|
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
Belden 29525C Applications
- Use in Variable Frequency Drives (VFD) for drive-to-motor connections.
- Install in AC motor and drive systems that require this cable type and construction.
- Specify for Class 1 Division 2 locations when the installation requires a cable identified for that location type.
Belden™ and all associated trademarks are the property of their respective owners.
Spécifications
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 6 AWG |
| Conductor stranding | 7x14 |
| Conductor notes | ASTM B3 Copper B8 Class B Stranding |
| Segmented ground wire | 3 x 12 AWG |
| Ground stranding | 7x20 |
| Ground notes | Segmented Grounds (3 Totaling 6AWG) |
| Insulation thickness (nom.) | 0.047 in (1.2 mm) |
| Insulation diameter (nom.) | 0.272 in (6.91 mm) |
| Color Code | ICEA Chart M4 |
| Ground wire | No Insulation |
| Shield Type | Helical Tape |
| Jacket thickness (nom.) | 0.063 in (1.6 mm) |
| Overall cable diameter (nominal) | 0.724 in (18.4 mm) |
| Nom. conductor DCR | 0.355 Ohm/1000ft (1.16 Ohm/km) |
| Nom. capacitance cond-to-cond | 32 pF/ft (100 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 63 pF/ft (210 pF/m) |
| Nom. characteristic impedence | 37 Ohm |
| Nom. velocity of prop. | 55% |
| Max. current | 75 Amps per Conductor at 30ºC |
| Nom. outer shield DCR | 2.72 Ohm/1000ft (8.92 Ohm/km) |
| Operating | -40°C To +90°C |
| Stationary min. bend radius | 8.7 in (220 mm) |
| Installation min. bend radius | 8.7 in (220 mm) |
| Max Pull Tension | 1304.1 lbs (591.53 kg) |
| Bulk cable weight | 461 lbs/1000ft (686 kg/km) |
| Environmental marking | SUN RES DIR BUR |
| Oil Resistant | Oil Resistant |
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202 FT4, FT4 |
| NEC / UL compliance | Article 336, TC-ER, XHHW-2 |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
| Priced Per | FT |
Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.