Belden 29532, Multi Conductor 3C4 0 133STC VFD 600V Black

SKU:Belden 29532
● En stock
Description
Belden 29532 is a 100% ground flexible VFD cable for Variable Frequency Drives (VFD) and AC motor and drive systems, including Class 1 Division 2 hazardous locations. It is built with 3 Stranded 4/0 AWG TC - Tinned Copper conductors, XLPE - Cross-Linked Polyethylene (Thermoset) insulation, and a black PVC - Polyvinyl Chloride outer jacket with ripcord. The design includes a symmetrical segmented ground (3 of 2 AWG) in continuous contact with an overall dual copper tape helical shield for high-frequency performance. It is rated 600/1000V with UL temperature 90°C Dry, 90°C Wet and environmental suitability for Indoor, Outdoor, Sunlight Resistance, Burial.
Belden 29532 Key Features
- 100% ground flexible VFD cable designed for Variable Frequency Drives (VFD) and AC motor and drive systems, including Class 1 Division 2 hazardous locations.
- 3 Stranded 4/0 AWG TC - Tinned Copper conductors with Conductor Stranding: 7x19x18 and Notes: Fine Strand Optomized for VF Applications.
- Symmetrical segmented ground with Earth/ground wires: Yes, Segmented ground Wire: 3, Ground Wire size: 2 AWG, Ground Wire material: BC - Bare Copper, and Ground Wire Stranding: 7x19x23.
- Overall dual copper tape helical shield with Coverage: 100% and Notes: 2 mil helical copper for crack resistance and high frequency performance.
- Black PVC - Polyvinyl Chloride outer jacket with Ripcord: Yes and Environmental suitability: Indoor, Outdoor, Sunlight Resistance, Burial.
- Voltage rating: 600/1000V with UL Voltage Rating: 1000 V (TC, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) and Voltage range: 1KV.
- Temperature ratings include UL temperature: 90°C Dry, 90°C Wet and Operating: -40°C To +90°C.
Belden 29532 Technical Specs
Construction & Materials
| Number of conductors | 3 |
|---|---|
| Conductor size | 4/0 AWG |
| Conductor material | TC - Tinned Copper |
| Conductor stranding | 7x19x18 |
| Ground wire size | 2 AWG |
| Ground wire material | BC - Bare Copper |
| Ground wire stranding | 7x19x23 |
| Ground notes | Segmented Grounds (3 Totaling 4/0 AWG) |
| Insulation material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Nom. thickness | 0.057 in (1.4 mm) |
| Nom. insulation diameter | 0.669 in (17.0 mm) |
| Color code | ICEA Chart M4 |
| Shield type | Helical Tape |
| Shield material | Bare Copper (BC) |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket color | Black |
| Nom. jacket thickness | 0.083 in (2.1 mm) |
| Armor | No |
| Composite | No |
Electrical & Signal Characteristics
| Nom. conductor DCR | 0.047 Ohm/1000ft (0.15 Ohm/km) |
|---|---|
| Nom Outer Shield DCR | 0.090 Ohm/1000ft (0.30 Ohm/km) |
| Segmented ground Wire DCR | 0.05 Ohm/1000ft (0.16 Ohm/km) |
| Nom. capacitance Cond-to-Cond | 33 pF/ft (110 pF/m) |
| Nom. capacitance Cond-to-other (Conds + Shield) | 60 pF/ft (200 pF/m) |
| Nom. characteristic impedence | 56 Ohm |
| Nom. inductance Cond-grnd | 0.055 μH/ft |
| Nom. inductance | 0.136 μH/ft (0.446 μH/m) |
| Nom. velocity of prop. | 55% |
| Max. current | 260 Amps per Conductor at 30ºC |
Physical Dimensions & Handling
| Nom. diameter | 1.620 in (41.15 mm) |
|---|---|
| Overall cable diameter (nominal) | 1.620 in (41.15 mm) |
| Stationary min. bend radius | 19.4 in (493 mm) |
| Installation min. bend radius | 19.4 in (493 mm) |
| Max. pull tension | 10048 lbs (4557.7 kg) |
| Bulk cable weight | 3185 lbs/1000ft (4740 kg/km) |
Environmental & Mechanical Ratings
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, IEEE 1202 FT4 |
|---|
Compliance & Certifications
| NEC / UL compliance | Article 336, TC-ER, WTTC, XHHW-2, UL Flexible Motor Supply Cable |
|---|---|
| CEC / C(UL) compliance | TC |
| ICEA compliance | S-95-658 |
| European Directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
Belden 29532 Applications
- Use in Variable Frequency Drives (VFD) where a purpose-built VFD cable is needed for motor power connections.
- Connect AC motor and drive systems in industrial electrical installations.
- Specify for Class 1 Division 2 hazardous locations when the installation requires a cable identified for that environment.
- Recommended cable gland BTC200A1741RA is listed for use with this cable.
Belden™ and all associated trademarks are the property of their respective owners.
Spécifications
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 4/0 AWG |
| Conductor Material | TC - Tinned Copper |
| Conductor stranding | 7x19x18 |
| Ground wire size | 2 AWG |
| Ground wire material | BC - Bare Copper |
| Ground wire stranding | 7x19x23 |
| Ground notes | Segmented Grounds (3 Totaling 4/0 AWG) |
| Insulation Material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Nom. thickness | 0.057 in (1.4 mm) |
| Nom. insulation diameter | 0.669 in (17.0 mm) |
| Color Code | ICEA Chart M4 |
| Shield Type | Helical Tape |
| Shield Material | Bare Copper (BC) |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Nom. jacket thickness | 0.083 in (2.1 mm) |
| Armor | No |
| Composite | No |
| Nom. conductor DCR | 0.047 Ohm/1000ft (0.15 Ohm/km) |
| Nom. outer shield DCR | 0.090 Ohm/1000ft (0.30 Ohm/km) |
| Segmented ground Wire DCR | 0.05 Ohm/1000ft (0.16 Ohm/km) |
| Nom. capacitance cond-to-cond | 33 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 60 pF/ft (200 pF/m) |
| Nom. characteristic impedence | 56 Ohm |
| Nom. inductance cond-grnd | 0.055 µH/ft |
| Nom. inductance | 0.136 µH/ft (0.446 µH/m) |
| Nom. velocity of prop. | 55% |
| Max. current | 260 Amps per Conductor at 30ºC |
| Nom. diameter | 1.620 in (41.15 mm) |
| Overall cable diameter (nominal) | 1.620 in (41.15 mm) |
| Stationary min. bend radius | 19.4 in (493 mm) |
| Installation min. bend radius | 19.4 in (493 mm) |
| Max Pull Tension | 10048 lbs (4557.7 kg) |
| Bulk cable weight | 3185 lbs/1000ft (4740 kg/km) |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, TC-ER, WTTC, XHHW-2, UL Flexible Motor Supply Cable |
| CEC / C(UL) compliance | TC |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
| Priced Per | FT |
Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.
Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?
Notre équipe établit des devis pour les longueurs personnalisées et les commandes en gros, généralement le jour même.